HomeMy WebLinkAboutP19-000185 - plumbingPERMIT PROJECT
FILE #: 19-001149
690 PINEHURST CT MOUND MN 55364
NEW BUILD PLUBMING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000185 new build plubming
Created On
09/05/2019 by Anne Hentges
Notes
Under ground
DATES
Date
09/06/2019
From
1: 00 PM
To
1: 30 PM
Completion Date
09/06/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
100 DWV PVC Schedule #40
101 Water lines insulted
102 5# air test holding
Jason R.
PERMIT PROJECT
FILE #: 19-001149
690 PINEHURST CT MOUND MN 55364
NEW BUILD PLUBMING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000185 new build plubming
Created On
10/03/2019 by Nola Dickhausen
Notes
DATES
Date
10/08/2019
From
3: 00 PM
To
3: 30 PM
Completion Date
10/08/2019
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 DWV PVC sch 40 with 5 lb air test holding.
1. Provide structural straps on top plates of all bearing walls with plumbing penetrations extending 6 in. past
penetrations.
Rest appears ok , correct and ok to continue. Jim H.
PERMIT PROJECT
FILE #: 19-001149
690 PINEHURST CT MOUND MN 55364
NEW BUILD PLUBMING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000185 new build plubming
Created On
01/06/2020 by Anne Hentges
Notes
DATES
Date
01/07/2020
From
11: 00 AM
To
11: 30 AM
Completion Date
01/07/2020
Status
Correct Work & Proceed
Erosion Control Checked, Found Compliant
Is Vegetation Established
#STATUS COMMENTS
INSPECTION COMMENTS
0 Plumbing manometer is holding. Water heater TPR valve discharges ok. Sump basket sealed.
1. Seal WC master bath. Rest of xtures set and sealed.
2. Provide VB for hose bib on pressure tank in mech room. Rest of work appears complete. Correct and will
check at building nal or mech nal re-inspection. Jim H.
PERMIT PROJECT
FILE #: 19-001149
690 PINEHURST CT MOUND MN 55364
NEW BUILD PLUBMING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000185 new build plubming
Created On
01/17/2020 by Anne Hentges
Notes
DATES
Date
01/20/2020
From
3: 00 PM
To
3: 30 PM
Completion Date
01/20/2020
Status
Correct Work & Proceed
Erosion Control Checked, Found Compliant
Is Vegetation Established
#STATUS COMMENTS
INSPECTION COMMENTS
0 1. Seal WC master bath.
2. Provide VB on hose bib at pressure tank, both per prior inspections. Correct and will check at building
l i
1 Plumbing manometer is holding. Water heater TPR valve discharges ok. Sump basket sealed.
1. Seal WC master bath. Rest of xtures set and sealed.
2. Provide VB for hose bib on pressure tank in mech room. Rest of work appears complete. Correct and will
check at building nal or mech nal re-inspection. Jim H.
PERMIT PROJECT
FILE #: 19-001149
690 PINEHURST CT MOUND MN 55364
NEW BUILD PLUBMING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000185 new build plubming
Created On
02/26/2020 by Anne Hentges
Notes
DATES
Date
02/27/2020
From
9: 45 AM
To
10: 15 AM
Completion Date
02/27/2020
Status
Permit Finaled
Erosion Control Checked, Found Compliant
Is Vegetation Established
#STATUS COMMENTS
INSPECTION COMMENTS
0 Corrections completed ok to nal.
Jason R.
1 1. Seal WC master bath.
2. Provide VB on hose bib at pressure tank, both per prior inspections. Correct and will check at building
nal. Jim H.
2 Plumbing manometer is holding. Water heater TPR valve discharges ok. Sump basket sealed.
1. Seal WC master bath. Rest of xtures set and sealed.
2. Provide VB for hose bib on pressure tank in mech room. Rest of work appears complete. Correct and will
check at building nal or mech nal re-inspection. Jim H.