Loading...
HomeMy WebLinkAboutP19-000182 - plumbingPERMIT PROJECT FILE #: 19-001110 4340 LAKEVIEW CT MOUND MN 55364 INSIDE PLUMBING FOR NEW CONSTRUCTION HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000182 INSIDE PLUMBING FOR NE... Created On 10/16/2019 by Anne Hentges Notes Under ground DATES Date 10/24/2019    From 1: 00  PM To 1: 30  PM Completion Date 10/24/2019 Status Not ready: Reinspect #STATUS COMMENTS   INSPECTION COMMENTS  0 Work not ready. Call for reinspection. Jason R.  PERMIT PROJECT FILE #: 19-001110 4340 LAKEVIEW CT MOUND MN 55364 INSIDE PLUMBING FOR NEW CONSTRUCTION HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000182 INSIDE PLUMBING FOR NE... Created On 11/26/2019 by Nola Dickhausen Notes DATES Date 12/03/2019    From 2: 30  PM To 3: 00  PM Completion Date 12/03/2019 Status Correct Work & Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 UG and AG DWV PVC sch 40 with 5lb air test holding. Radon to be vented out of sump basket. 1. Provide additional stud in bearing wall supporting stairway header penetrated by plumbing. Rest appears ok. Correct and ok to continue. Jim H.  PERMIT PROJECT FILE #: 19-001110 4340 LAKEVIEW CT MOUND MN 55364 INSIDE PLUMBING FOR NEW CONSTRUCTION HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000182 INSIDE PLUMBING FOR NE... Created On 02/26/2020 by Anna Carlson Notes DATES Date 03/02/2020    From 8: 30  AM To 9: 00  AM Completion Date 03/02/2020 Status Inspection Failed: Reinspect  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS   INSPECTION COMMENTS  0 Fixtures set and sealed. Mixing valve provided for free standing tub. 1. Provide manometer. 2. Provide VB testing and report for irrigation VB. 3. Seal all sump baskets and ejector pump basket lids. 4. Provide VB for hose bib at pressure tank. Correct and call for reinspection. Jim H.  PERMIT PROJECT FILE #: 19-001110 4340 LAKEVIEW CT MOUND MN 55364 INSIDE PLUMBING FOR NEW CONSTRUCTION HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000182 INSIDE PLUMBING FOR NE... Created On 03/03/2020 by Anne Hentges Notes DATES Date 03/05/2020    From 9: 00  AM To 9: 30  AM Completion Date 03/05/2020 Status Inspection Passed: Proceed  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS     INSPECTION COMMENTS  0 Manometer holding. Vacuum breaker for irrigation system tested. 0 Seal ejector pump basket. 0 Provide vacuum breaker at well system boiler drain In mechanical room..in mechanical room.  PERMIT PROJECT FILE #: 19-001110 4340 LAKEVIEW CT MOUND MN 55364 INSIDE PLUMBING FOR NEW CONSTRUCTION HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000182 INSIDE PLUMBING FOR NE... Created On 03/09/2020 by Anne Hentges Notes DATES Date 03/11/2020    From 9: 15  AM To 9: 45  AM Completion Date 03/11/2020 Status Permit Finaled  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS      INSPECTION COMMENTS  0 Corrections provided, all work complete. Permit naled. Jim H. 1 Manometer holding. Vacuum breaker for irrigation system tested. 2 Complete Seal ejector pump basket. 3 Provide vacuum breaker at well system boiler drain In mechanical room..in mechanical room. 