HomeMy WebLinkAboutP19-000177 - roof drainsPERMIT PROJECT FILE #: 19-001086 325 CRESTVIEW AVE LONG LAKE MN 55356 INSTALL (6) ROOF DRAINS  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000177 Install (6) roof drains  Created On 08/16/2019 by Anne Hentges Notes DATES Date 08/19/2019    From 1: 30  PM To 2: 00  PM Completion Date 11/21/2019 Status Permit Finaled #STATUS COMMENTS     INSPECTION COMMENTS  0 3 roof drains with separate overows - PVC sch 40. 5 lb air tests are holding,(each tested separately). Exteriors are sealed. OK to continue. Jim H. 0 3 roof drains with separate overows - PVC sch 40. 5 lb air tests are holding,(each tested separately). Exteriors are sealed. OK to continue. Jim H. 1 1. Provide air test for all roof drains and over ow drains.. 2. Provide access to roof for visual inspection of roof drains and overow drains. 3. Seal all exterior penetrations for drains. Correct and call for reinspection. Jim H.  PERMIT PROJECT FILE #: 19-001086 325 CRESTVIEW AVE LONG LAKE MN 55356 INSTALL (6) ROOF DRAINS  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000177 Install (6) roof drains  Created On 08/09/2019 by Anne Hentges Notes DATES Date 08/12/2019    From 11: 00  AM To 11: 30  AM Completion Date 08/12/2019 Status Inspection Passed: Proceed  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS   INSPECTION COMMENTS  0 Provide access to roof. Air tests required for roof drains  PERMIT PROJECT FILE #: 19-001086 325 CRESTVIEW AVE LONG LAKE MN 55356 INSTALL (6) ROOF DRAINS  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000177 Install (6) roof drains  Created On 08/12/2019 by Anne Hentges Notes DATES Date 08/13/2019    From 10: 00  AM To 10: 30  AM Completion Date 08/13/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 1. Provide air test for all roof drains and over ow drains.. 2. Provide access to roof for visual inspection of roof drains and overow drains. 3. Seal all exterior penetrations for drains. Correct and call for reinspection. Jim H.  PERMIT PROJECT FILE #: 19-001086 325 CRESTVIEW AVE LONG LAKE MN 55356 INSTALL (6) ROOF DRAINS  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000177 Install (6) roof drains  Created On 11/21/2019 by Nola Dickhausen Notes DATES Date 08/19/2019    From 1: 30  PM To 2: 00  PM Completion Date 08/19/2019 Status Permit Finaled  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS     INSPECTION COMMENTS  0 5# air test is holding, leach tested separately. 0 3 roof drains &3 overow drains - DWV - PVC sch 40 - supports - ok - exteriors are sealed 2 Complete Provide access to roof. Air tests required for roof drains 