HomeMy WebLinkAboutP19-000146 - plumbingPERMIT PROJECT
FILE #: 19-000893
3685 TOGO RD WAYZATA MN 55391
BATHROOM REMODEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000146 Bathroom remodel
Created On
09/10/2019 by Nola Dickhausen
Notes
DATES
Date
09/13/2019
From
2: 30 PM
To
3: 00 PM
Completion Date
09/13/2019
Status
#STATUS COMMENTS
INSPECTION COMMENTS
0 Correct ABS to PVC connections At stack in attic and toilet Waste.
Jason R.
0 Provide nail plates.
0 Continue 2 inch stack through roof.
PERMIT PROJECT
FILE #: 19-000893
3685 TOGO RD WAYZATA MN 55391
BATHROOM REMODEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000146 Bathroom remodel
Created On
09/23/2019 by Anne Hentges
Notes
DATES
Date
09/25/2019
From
10: 00 AM
To
10: 30 AM
Completion Date
09/25/2019
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Correct ABS to PVC connections At stack in attic and toilet Waste.
Jason R.
0 Complete Provide nail plates.
0 Complete Continue 2 inch stack through roof.
0 Visual for bathroom remodel. Vent thru roof, ABS sch 40 to cast iron thru roof connected with mission band.
Nail plates provided per correction.
1. Correct ABS to PVC back to ABS connection for toilet waste. Allowed only one transition,(ie. ABS to PVC
and continue with PVC, cannot convert back to ABS with glued tting). Can use mission bands at transition
ttings.
OK to cover walls, call for reinspection on toilet waste. Jim H.
PERMIT PROJECT
FILE #: 19-000893
3685 TOGO RD WAYZATA MN 55391
BATHROOM REMODEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Gary Nelson
Permit #:
P19-000146 Bathroom remodel
Created On
03/11/2022 by Katie Fitzsimmons
Notes
DATES
Date
03/15/2022
From
9: 00 AM
To
10: 00 AM
Completion Date
03/15/2022
Status
Permit Finaled
Erosion Control Checked, Found Compliant
Is Vegetation Established
#STATUS COMMENTS
INSPECTION COMMENTS