HomeMy WebLinkAboutP19-000126 - plumbingPERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
08/13/2019 by Anne Hentges
Notes
Plumbing UG
DATES
Date
08/13/2019
From
1: 30 PM
To
2: 00 PM
Completion Date
08/13/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 UG for oor drains in garage. 4 inch Sch40 PVC, contrasting cleaner used pitch looks good. Air test
holding at this time. Okay to back ll.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/19/2019 by Roger Peitso
Notes
DATES
Date
09/19/2019
From
2: 30 PM
To
3: 00 PM
Completion Date
09/19/2019
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
1 Deep underground slab on grade wing West corridor North to South. T at East to West corridor
approximately 40 feet
2 4 inch Sch 40 PVC North and South. 6 inch T heading East. Contrasting cleaner used pitch looks good.
3 No air test at this time nish bedding 6 inch rest looks good okay to back ll.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/23/2019 by Anne Hentges
Notes
Plumbing UG
DATES
Date
09/24/2019
From
9: 00 AM
To
9: 30 AM
Completion Date
09/24/2019
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 UG for 1st oor units bathroom groups and 2 oor drains West end of slab on grade wing. Waste and vent
PVC sch 40 contrasting cleaner used pitch looks good
0 Pressure test holding at this time. Provide 5psi on entire system when completed.
0 Finish bedding piping last 2 units NW corner East side of corridor
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/25/2019 by Anne Hentges
Notes
Plumbing UG
DATES
Date
09/25/2019
From
1: 30 PM
To
2: 00 PM
Completion Date
09/25/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 PVC schedule 40 pitch looks good okay to back ll. P.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/26/2019 by Nola Dickhausen
Notes
DATES
Date
09/26/2019
From
3: 30 PM
To
4: 00 PM
Completion Date
09/26/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 2 bathroom groups South side of courtyard. And storm sewer inside building connecting to exterior storm
sewer for courtyard. Pressure test holding at this time. Okay to back ll
0 Contrasting cleaner used PVC Sch #40
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/30/2019 by Nola Dickhausen
Notes
UG
DATES
Date
09/30/2019
From
2: 00 PM
To
2: 30 PM
Completion Date
09/30/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 UG deep main 6 inch pvc , contrasting cleaner used. Pitch looks good. Provide 5psi on entire system.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Air Test
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
09/30/2019 by Nola Dickhausen
Notes
DATES
Date
10/01/2019
From
8: 30 AM
To
9: 00 AM
Completion Date
10/01/2019
Status
Inspection Passed: Proceed
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 5psi on all work completed to this point, 4 units left for slab on grade. Holding at this time, provide 5psi on
entire system when completed
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
10/01/2019 by Roger Peitso
Notes
UG rough in
DATES
Date
10/01/2019
From
11: 00 AM
To
11: 30 AM
Completion Date
10/01/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 5psi on all work completed to this point, 4 units left for slab on grade. Holding at this time, provide 5psi on
entire system when completed
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
10/02/2019 by Nola Dickhausen
Notes
DATES
Date
10/02/2019
From
1: 00 PM
To
1: 30 PM
Completion Date
10/02/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 2 more units near East end of slab on grade structure. Waste looks good contrasting cleaner used PVC
Sch 40.
5psi is holding at this time. Okay to back ll.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
10/11/2019 by Anne Hentges
Notes
Visual Inspection - inside
DATES
Date
10/14/2019
From
11: 30 AM
To
12: 00 PM
Completion Date
10/14/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Room 1-12 waste vent looks good. Contrasting cleaner used, PVC Sch 40 looks good.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
10/17/2019 by Anne Hentges
Notes
Under-Ground
DATES
Date
10/18/2019
From
10: 30 AM
To
11: 00 AM
Completion Date
10/18/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Entire underground for slab on grade plumbing is air tested. Holding at this time. Waste and vent PVC Sch
40 contrasting cleaner used. Looks good okay to back ll.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
12/02/2019 by Nola Dickhausen
Notes
DATES
Date
12/02/2019
From
3: 00 PM
To
3: 30 PM
Completion Date
12/02/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Inspector was ill, contractor to reschedule
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
12/03/2019 by Roger Peitso
Notes
DATES
Date
12/05/2019
From
10: 00 AM
To
11: 00 AM
Completion Date
12/05/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Waste and vent Schedule 40 PVC, contrasting cleaner used.
0 5 psi on garage portion of building 1st and 2nd oors only holding at this time.
0 Supports and re caulking looks good.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
01/09/2020 by Nola Dickhausen
Notes
Garage
DATES
Date
01/10/2020
From
9: 00 AM
To
9: 30 AM
Completion Date
01/10/2020
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Garage portion of building 5psi on entire system except commercial kitchen. Passed
0 Sch 40 PVC contrasting cleaner used. Supports looks good, clean outs ok
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
03/10/2020 by Anne Hentges
Notes
DATES
Date
03/11/2020
From
10: 30 AM
To
11: 00 AM
Completion Date
03/11/2020
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
1 1st oor recheck M-5, M-6, M-4, M-8, M-3, M-9, M-2, M-10, M-11, M-1, M-12, M-13, M-14, M-16, M-17, M-19,
M-22, M-23, M-24, 119 shipping and receiving, 118 Bathroom, 117 laundry, 116 break room, A-1, A-3, A-2,
A-4, 2- Bathrooms, A-5,
2 Re-inspection Required M-15 wall not centered, M-18 wall not centered, M-20 wall not centered, M-21 Maintain 12 inch RI for
toilet, A-6 wall off center kitchen cabinet, will check these corrections a framing inspection.
3 Re-inspection Required Roof drains required per 2015 Minnesota Building Code shall be installed for a at roofs that have barriers
that impede drainage. See below.
#STATUS COMMENTS
4 Re-inspection Required 1503.4 Roof drainage.
Design and installation of roof drainage systems shall comply with Minnesota Rules, Chapter 4715,
Minnesota Plumbing Code, and the following provisions:
1. Where required.
All roofs shall drain into a separate storm sewer system or to an approved place of disposal. For one-
and two-family dwellings, and where approved, storm water is permitted to discharge onto at areas,
such as streets or lawns, provided that the storm water ows away from the building.
2. Roof design.
Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined
by the relative levels of roof deck and over ow weirs, scuppers, edges, or serviceable drains in
combination with the de ected structural elements. In determining the maximum possible depth of
water, all primary roof drainage means shall be assumed to be blocked.
3. Secondary drainage required.
Secondary (emergency) roof drains or scuppers shall be provided where the roof perimeter
construction extends above the roof in such a manner that water will be entrapped if the primary drains
allow buildup for any reason.
4. Separate systems required.
Secondary (emergency) roof drain systems shall have piping and point of discharge separate from the
primary system. Discharge shall be above grade in a location which would normally be observed by the
building occupants or maintenance personnel.
5. Sizing of secondary drains.
Secondary (emergency) roof drain systems shall be sized in accordance with the Minnesota State
Plumbing Code. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for
which the roof was designed as determined by this code. Scuppers shall not have an opening
dimension of less than 4 inches (102 mm). The ow through the primary system shall not be
considered when sizing the secondary roof drainage system.
[P] 1503.4.1 Secondary (emergency over ow) drains or scuppers.
Deleted.
Deleted
1503.4.2 Scuppers.
When scuppers are used for secondary (emergency over ow) roof drainage, the quantity, size, location
and inlet elevation of the scuppers shall be sized to prevent the depth of ponding water from exceeding
h f hi h h f d i d d i d b S i 1 11 1 S h ll h
1503.4 Roof drainage.
Design and installation of roof drainage systems shall comply with Minnesota Rules, Chapter 4715, Minnesota Plumbing Code, and the following
provisions:
1. Where required.
All roofs shall drain into a separate storm sewer system or to an approved place of disposal. For one- and two-family dwellings, and where approved,
storm water is permitted to discharge onto flat areas, such as streets or lawns, provided that the storm water flows away from the building.
2. Roof design.
Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined by the relative levels of roof deck and overflow
weirs, scuppers, edges, or serviceable drains in combination with the deflected structural elements. In determining the maximum possible depth of water,
all primary roof drainage means shall be assumed to be blocked.
3. Secondary drainage required.
Secondary (emergency) roof drains or scuppers shall be provided where the roof perimeter construction extends above the roof in such a manner that
water will be entrapped if the primary drains allow buildup for any reason.
4. Separate systems required.
Secondary (emergency) roof drain systems shall have piping and point of discharge separate from the primary system. Discharge shall be above grade in
a location which would normally be observed by the building occupants or maintenance personnel.
5. Sizing of secondary drains.
Secondary (emergency) roof drain systems shall be sized in accordance with the Minnesota State Plumbing Code. Scuppers shall be sized to prevent the
depth of ponding water from exceeding that for which the roof was designed as determined by this code. Scuppers shall not have an opening dimension of
less than 4 inches (102 mm). The flow through the primary system shall not be considered when sizing the secondary roof drainage system.
[P] 1503.4.1 Secondary (emergency overflow) drains or scuppers.
Deleted.
Deleted
1503.4.2 Scuppers.
When scuppers are used for secondary (emergency overflow) roof drainage, the quantity, size, location and inlet elevation of the scuppers shall be sized
to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by Section 1611.1. Scuppers shall not have an
opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when locating and sizing scuppers.
1503.4.3 Gutters.
Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall be of
noncombustible material or a minimum of Schedule 40 plastic pipe.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
04/09/2020 by Roger Peitso
Notes
DATES
Date
04/09/2020
From
2: 30 PM
To
3: 00 PM
Completion Date
04/09/2020
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Kitchen plumbing 5psi passed waste and vent PVC Sch 40 looks good, contrasting cleaner used. Entire
plumbing system has had a rough in inspection.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
06/23/2020 by Roger Peitso
Notes
Partial nal
DATES
Date
06/23/2020
From
9: 00 AM
To
9: 30 AM
Completion Date
06/23/2020
Status
Correct Work & Proceed
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Checked manometers for Phase 2 all passed.
0 Checked all xtures and receptacles 1st oor only. Fixtures sealed rest looks good.
0 Re-inspection Required Mop sink for room 133A
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Set & Seal
Assign To
Anne Hentges
Permit #:
P19-000126 Plumbing per plan
Created On
06/23/2020 by Anne Hentges
Notes
DATES
Date
06/24/2020
From
10: 00 AM
To
10: 30 AM
Completion Date
06/24/2020
Status
Inspection Passed: Proceed
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Hand Wash Meter (Temporary) Reading 00078963.30 06-24-20 Retired Meter
0 1" Main Meter
ERT: 1563653078
SN# 54652172
Reading 0355321.97
0 2" Irrigation meter
ERT 1566308416
SN#: 61134865 (Lower)
Reading: 00013633.6
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
06/23/2020 by Alicia Johnson
Notes
DATES
Date
06/25/2020
From
1: 00 PM
To
2: 30 PM
Completion Date
06/25/2020
Status
Correct Work & Proceed
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Re-inspection Required Caulk oor mop sinks on rst and 2nd oors. Will check at building this nal
0 Inspected rest of 2nd oor plumbing checked all units, o ces, storage. Work appears complete in
0 Re-inspection Required Dishwasher in main kitchen has not been connected to plumbing system.
PERMIT PROJECT
FILE #: 19-000783
2635 KELLEY PKWY LONG LAKE MN 55356
PLUMBING PER PLAN
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000126 Plumbing per plan
Created On
10/02/2020 by Roger Peitso
Notes
DATES
Date
07/09/2020
From
1: 30 PM
To
2: 00 PM
Completion Date
07/09/2020
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Complete Dishwasher in main kitchen has not been connected to plumbing system.
3 Complete Mop sink for room 133A