HomeMy WebLinkAboutP19-000126 - plumbingPERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 08/13/2019 by Anne Hentges Notes Plumbing UG DATES Date 08/13/2019    From 1: 30  PM To 2: 00  PM Completion Date 08/13/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 UG for oor drains in garage. 4 inch Sch40 PVC, contrasting cleaner used pitch looks good. Air test holding at this time. Okay to back ll.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/19/2019 by Roger Peitso Notes DATES Date 09/19/2019    From 2: 30  PM To 3: 00  PM Completion Date 09/19/2019 Status Correct Work & Proceed #STATUS COMMENTS     INSPECTION COMMENTS  1 Deep underground slab on grade wing West corridor North to South. T at East to West corridor approximately 40 feet 2 4 inch Sch 40 PVC North and South. 6 inch T heading East. Contrasting cleaner used pitch looks good. 3 No air test at this time nish bedding 6 inch rest looks good okay to backll.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/23/2019 by Anne Hentges Notes Plumbing UG DATES Date 09/24/2019    From 9: 00  AM To 9: 30  AM Completion Date 09/24/2019 Status Correct Work & Proceed #STATUS COMMENTS     INSPECTION COMMENTS  0 UG for 1st oor units bathroom groups and 2 oor drains West end of slab on grade wing. Waste and vent PVC sch 40 contrasting cleaner used pitch looks good 0 Pressure test holding at this time. Provide 5psi on entire system when completed. 0 Finish bedding piping last 2 units NW corner East side of corridor  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/25/2019 by Anne Hentges Notes Plumbing UG DATES Date 09/25/2019    From 1: 30  PM To 2: 00  PM Completion Date 09/25/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 PVC schedule 40 pitch looks good okay to backll. P.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/26/2019 by Nola Dickhausen Notes DATES Date 09/26/2019    From 3: 30  PM To 4: 00  PM Completion Date 09/26/2019 Status Inspection Passed: Proceed #STATUS COMMENTS    INSPECTION COMMENTS  0 2 bathroom groups South side of courtyard. And storm sewer inside building connecting to exterior storm sewer for courtyard. Pressure test holding at this time. Okay to backll 0 Contrasting cleaner used PVC Sch #40  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/30/2019 by Nola Dickhausen Notes UG DATES Date 09/30/2019    From 2: 00  PM To 2: 30  PM Completion Date 09/30/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 UG deep main 6 inch pvc , contrasting cleaner used. Pitch looks good. Provide 5psi on entire system.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Air Test   Assign To Permit #: P19-000126 Plumbing per plan  Created On 09/30/2019 by Nola Dickhausen Notes DATES Date 10/01/2019    From 8: 30  AM To 9: 00  AM Completion Date 10/01/2019 Status Inspection Passed: Proceed  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 5psi on all work completed to this point, 4 units left for slab on grade. Holding at this time, provide 5psi on entire system when completed  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 10/01/2019 by Roger Peitso Notes UG rough in DATES Date 10/01/2019    From 11: 00  AM To 11: 30  AM Completion Date 10/01/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 5psi on all work completed to this point, 4 units left for slab on grade. Holding at this time, provide 5psi on entire system when completed  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 10/02/2019 by Nola Dickhausen Notes DATES Date 10/02/2019    From 1: 00  PM To 1: 30  PM Completion Date 10/02/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 2 more units near East end of slab on grade structure. Waste looks good contrasting cleaner used PVC Sch 40. 5psi is holding at this time. Okay to backll.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 10/11/2019 by Anne Hentges Notes Visual Inspection - inside DATES Date 10/14/2019    From 11: 30  AM To 12: 00  PM Completion Date 10/14/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Room 1-12 waste vent looks good. Contrasting cleaner used, PVC Sch 40 looks good.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 10/17/2019 by Anne Hentges Notes Under-Ground DATES Date 10/18/2019    From 10: 30  AM To 11: 00  AM Completion Date 10/18/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Entire underground for slab on grade plumbing is air tested. Holding at this time. Waste and vent PVC Sch 40 contrasting cleaner used. Looks good okay to back ll.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 12/02/2019 by Nola Dickhausen Notes DATES Date 12/02/2019    From 3: 00  PM To 3: 30  PM Completion Date 12/02/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Inspector was ill, contractor to reschedule  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 12/03/2019 by Roger Peitso Notes DATES Date 12/05/2019    From 10: 00  AM To 11: 00  AM Completion Date 12/05/2019 Status Inspection Passed: Proceed #STATUS COMMENTS     INSPECTION COMMENTS  0 Waste and vent Schedule 40 PVC, contrasting cleaner used. 0 5 psi on garage portion of building 1st and 2nd oors only holding at this time. 0 Supports and re caulking looks good.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 01/09/2020 by Nola Dickhausen Notes Garage DATES Date 01/10/2020    From 9: 00  AM To 9: 30  AM Completion Date 01/10/2020 Status Inspection Passed: Proceed #STATUS COMMENTS    INSPECTION COMMENTS  0 Garage portion of building 5psi on entire system except commercial kitchen. Passed 0 Sch 40 PVC contrasting cleaner used. Supports looks good, clean outs ok  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 03/10/2020 by Anne Hentges Notes DATES Date 03/11/2020    From 10: 30  AM To 11: 00  AM Completion Date 03/11/2020 Status Correct Work & Proceed #STATUS COMMENTS     INSPECTION COMMENTS  1 1st oor recheck M-5, M-6, M-4, M-8, M-3, M-9, M-2, M-10, M-11, M-1, M-12, M-13, M-14, M-16, M-17, M-19, M-22, M-23, M-24, 119 shipping and receiving, 118 Bathroom, 117 laundry, 116 break room, A-1, A-3, A-2, A-4, 2- Bathrooms, A-5, 2 Re-inspection Required M-15 wall not centered, M-18 wall not centered, M-20 wall not centered, M-21 Maintain 12 inch RI for toilet, A-6 wall off center kitchen cabinet, will check these corrections a framing inspection. 3 Re-inspection Required Roof drains required per 2015 Minnesota Building Code shall be installed for a at roofs that have barriers that impede drainage. See below.  #STATUS COMMENTS 4 Re-inspection Required 1503.4 Roof drainage. Design and installation of roof drainage systems shall comply with Minnesota Rules, Chapter 4715, Minnesota Plumbing Code, and the following provisions: 1. Where required. All roofs shall drain into a separate storm sewer system or to an approved place of disposal. For one- and two-family dwellings, and where approved, storm water is permitted to discharge onto at areas, such as streets or lawns, provided that the storm water ows away from the building. 2. Roof design. Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined by the relative levels of roof deck and overow weirs, scuppers, edges, or serviceable drains in combination with the deected structural elements. In determining the maximum possible depth of water, all primary roof drainage means shall be assumed to be blocked. 3. Secondary drainage required. Secondary (emergency) roof drains or scuppers shall be provided where the roof perimeter construction extends above the roof in such a manner that water will be entrapped if the primary drains allow buildup for any reason. 4. Separate systems required. Secondary (emergency) roof drain systems shall have piping and point of discharge separate from the primary system. Discharge shall be above grade in a location which would normally be observed by the building occupants or maintenance personnel. 5. Sizing of secondary drains. Secondary (emergency) roof drain systems shall be sized in accordance with the Minnesota State Plumbing Code. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by this code. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The ow through the primary system shall not be considered when sizing the secondary roof drainage system. [P] 1503.4.1 Secondary (emergency overow) drains or scuppers. Deleted. Deleted 1503.4.2 Scuppers. When scuppers are used for secondary (emergency overow) roof drainage, the quantity, size, location and inlet elevation of the scuppers shall be sized to prevent the depth of ponding water from exceeding h f hi h h f d i d d i d b S i 1 11 1 S h ll h 1503.4 Roof drainage. Design and installation of roof drainage systems shall comply with Minnesota Rules, Chapter 4715, Minnesota Plumbing Code, and the following provisions: 1. Where required. All roofs shall drain into a separate storm sewer system or to an approved place of disposal. For one- and two-family dwellings, and where approved, storm water is permitted to discharge onto flat areas, such as streets or lawns, provided that the storm water flows away from the building. 2. Roof design. Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined by the relative levels of roof deck and overflow weirs, scuppers, edges, or serviceable drains in combination with the deflected structural elements. In determining the maximum possible depth of water, all primary roof drainage means shall be assumed to be blocked. 3. Secondary drainage required. Secondary (emergency) roof drains or scuppers shall be provided where the roof perimeter construction extends above the roof in such a manner that water will be entrapped if the primary drains allow buildup for any reason. 4. Separate systems required. Secondary (emergency) roof drain systems shall have piping and point of discharge separate from the primary system. Discharge shall be above grade in a location which would normally be observed by the building occupants or maintenance personnel. 5. Sizing of secondary drains. Secondary (emergency) roof drain systems shall be sized in accordance with the Minnesota State Plumbing Code. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by this code. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when sizing the secondary roof drainage system. [P] 1503.4.1 Secondary (emergency overflow) drains or scuppers. Deleted. Deleted 1503.4.2 Scuppers. When scuppers are used for secondary (emergency overflow) roof drainage, the quantity, size, location and inlet elevation of the scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by Section 1611.1. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when locating and sizing scuppers. 1503.4.3 Gutters. Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall be of noncombustible material or a minimum of Schedule 40 plastic pipe. PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000126 Plumbing per plan  Created On 04/09/2020 by Roger Peitso Notes DATES Date 04/09/2020    From 2: 30  PM To 3: 00  PM Completion Date 04/09/2020 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Kitchen plumbing 5psi passed waste and vent PVC Sch 40 looks good, contrasting cleaner used. Entire plumbing system has had a rough in inspection.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000126 Plumbing per plan  Created On 06/23/2020 by Roger Peitso Notes Partial nal DATES Date 06/23/2020    From 9: 00  AM To 9: 30  AM Completion Date 06/23/2020 Status Correct Work & Proceed  Erosion Control Checked, Found Compliant #STATUS COMMENTS     INSPECTION COMMENTS  0 Checked manometers for Phase 2 all passed. 0 Checked all xtures and receptacles 1st oor only. Fixtures sealed rest looks good. 0 Re-inspection Required Mop sink for room 133A  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Set & Seal   Assign To Anne Hentges Permit #: P19-000126 Plumbing per plan  Created On 06/23/2020 by Anne Hentges Notes DATES Date 06/24/2020    From 10: 00  AM To 10: 30  AM Completion Date 06/24/2020 Status Inspection Passed: Proceed  Erosion Control Checked, Found Compliant #STATUS COMMENTS     INSPECTION COMMENTS  0 Hand Wash Meter (Temporary) Reading 00078963.30 06-24-20 Retired Meter 0 1" Main Meter ERT: 1563653078 SN# 54652172 Reading 0355321.97 0 2" Irrigation meter ERT 1566308416 SN#: 61134865 (Lower) Reading: 00013633.6  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000126 Plumbing per plan  Created On 06/23/2020 by Alicia Johnson Notes DATES Date 06/25/2020    From 1: 00  PM To 2: 30  PM Completion Date 06/25/2020 Status Correct Work & Proceed  Erosion Control Checked, Found Compliant #STATUS COMMENTS     INSPECTION COMMENTS  0 Re-inspection Required Caulk oor mop sinks on rst and 2nd oors. Will check at building this nal 0 Inspected rest of 2nd oor plumbing checked all units, oces, storage. Work appears complete in 0 Re-inspection Required Dishwasher in main kitchen has not been connected to plumbing system.  PERMIT PROJECT FILE #: 19-000783 2635 KELLEY PKWY LONG LAKE MN 55356 PLUMBING PER PLAN  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000126 Plumbing per plan  Created On 10/02/2020 by Roger Peitso Notes DATES Date 07/09/2020    From 1: 30  PM To 2: 00  PM Completion Date 07/09/2020 Status Permit Finaled  Erosion Control Checked, Found Compliant #STATUS COMMENTS    INSPECTION COMMENTS  0 Complete Dishwasher in main kitchen has not been connected to plumbing system. 3 Complete Mop sink for room 133A 