HomeMy WebLinkAboutSeptic inspections i
� .
� O " .
O`;��� O
1T`��`-�-� CI'T'Y of ORONO
�a ' ����.�� �
rv�'` ���` }�r��,� � P
� i�' � �',� ,�, Munici al Offices
�9� ,`�,���j�,
i+�`;rr����g�G Street Address: Mailing Address:
_ kEgH� 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crysta( Bay; MN 55323-0066
Owner. �oSep� �4�k2S Address: 170 (3-,q 15�q�J
City Ordinance 199 requires that each eYisUng on-site sewage treatment system in Orono be inspected every two years.
The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below.'
SYSTEM CONFORMITY (1-3): �
lO °CODE SYSTEM" An ISTS which mzets all the location,design and construction standazds ofthe current Orono htunicipal Code.
2 ��COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of tfiz current Orono Municipal
Code but does meet the three foot sepazalion requiremerrt,and which is not failing or an imminent threat to public heahh or safzty.
3 '�NON-COl�iPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plaiq any ISTS which may
or may not mzet all the location,design,or construction standazds of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturatzd soil or sand between tha distribution dzvice and the]imiting soil chara:trristics.
TANK CONDITION(�-10): 9 -
Tank inspec[ion indicates:
� Pumpout not nzzdzd at this tune.
6 Tank must bz pumped out this year (city code requires tanks to be pumped out zvzry 3 years. Tank was last pumpzd_ ),
7 Solids accumulation in tanks is at a critical a critical lzvzl. Tanks should be pumped out as soon as possiblz.
8 System is discharging to the surface. Tanks must be pumped out withirt 48 hours to eliminate surface discharge.
� Inspection risers missing-tanks could not be inspectzd. Inspection risers(4"di�pipe)must ba instailed in each tank at nei�t pumpout. If tanks
havz not bzen pumped out within thz last three years,they should be pumped out now.
1� Inspzction pipe is locatad directly over tank ba$le(does not give accurate meazurzment of solids accumulation). Iftanks have not been pumped
out wi�hin thz last three years,they should be pumped out now.
DRAINFIELD COivDITION(11-14): I I
11 Draintield is dry,no surfacing evidznt
12 Some zvidence of surfacing,not critical yet • ,
13 Drainfield is saturated and visibly dischazging untreated e$luent to the surface. Contact the City Inspector irrunediately.Repairs must be
completed within 90 days.
1=� Drainfield e.Ytznt and condition unknown.
COMNIENTS: SYs+e_.,. Z�S+q\\c� �- 5- 86
s�'-� 1 �'Y�c�C
Date of Inspection Septic System Inspector
Notz: In the evrnt tf:at this inspection repoct is used to satisfy the requirements for a moRgage or other uansfer of property,be advised tbaf this report does not guarantze
or certify that an existing systzm will continue to function propzriy,but is merely an opinion oftha adzquacy of the system under curre�conditions b�sed on the available
informalion.
.�, o,�,.
- � o 0
' ===-Y .�-� C ITY of OR�NO
Ij , �:r� � �
,� yi '� `�,
'�+� �..,�� .�.._: ';� ,�,FY Municipat Offices
� `` ��'����,r`,�ti G
l �' ' '`<7'��� «` Street Address: Mailing Address:
,,q � ,.��:,,� :g,�
�CEggO 2150 Kelley Parfcway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: J 0 S�p �1 u q C.K�'� Address: I ?� l.� �q �S �`��^�
Cin�Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site se«�age treatment system at the above address has been inspected and appears to fall into the categories checked below.
S�'STEM CONFORMIT'Y (1-3): �
� ��CODE SYSTEM" An ISTS which mzets all thz location,design and construction standards ofthe cucrent Orono Municipal Code.
\J
2 ��COMPLIANT SYSTEM" An ISTS which does not meet a(1 the location,design and construction standards ofthe cuirent Orono Municipal
Code but does meet thz three foot separation requirement,and which is not failing or an irruninent threat to public health or safety.
3 ��NON-COMPLIANT SYSTEM" Aprohibited ISTS;an ISTS locatzd within a designated 100-year flood plain,any ISTS which may
or may not mzet all the localioq dzsigi,or construction standards of the current Orono Municipal Code and which is failing for any reuon;and
any ISTS with less than thtte feet oFunsaturated soil or sand between the distribution davice and the limiting soil characteristics.
TANf�CONDITION(�-10): I O
Tank inspection indicates: -
� Pumpout not needed at this time.
� Tan1:must bz pumped out this year (city code requires tanks to be pumpzd out every 3 years. Tank was I�st pumped �,11�K!�p W n ).
�/ Solids accumulation in tanks is at a critical a critica((evaL Tanks shou(d be pumped out az soon as possiblz.
S Systzm is discharging to tht surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not bz inspected. Inspection riszrs(4"dia.pipe)must be installed in each tank at neM pumpout If tanks
ha��e no[brzn pumped out within the last thtez yzars,thzy should be pumped out now.
1� Inspaction pipa is loca[zd dirzcdy over tank ba$le(does not give accurate measurement of solids accumulalion). If tanks have not been pumped
out within the last three years,they should be pumpad out now.
DRAINFIELD CONDITION(11-14): � �
1 1 Dra�eld is dry,no surfacing tvident
1� Some e�'idence of surfacing,not critical yet � •
13 Drainfield is saturated and visibly discharging untraated e&luent to the surface. Contact the City Inspector immediately.Repairs must be
complated��ithin 90 days.
1� Draintizld e�tent and condition unknown.
CO�uL�NTS: S� Ste M �'S-i' ��nS �t���c� '�- �� , l.� v*^ � �--i-�-��.�
�a5� 3 ye�.cS p� ,,�, p� �•v, b� ��kS no} neeclee .
��� � � � 4� �/���2J'rv.�,,,�
Date of Inspection Septic System Inspector
\otz: In the event that this inspection report is uszd to satisfy the requuemznis for a moRgage or other transfer of property,be advised that this report does not guarantze
or ceRify that an eusting system will continue to funetion propetiy,but is merely an opinion of the adequacy of the system under cucrent conditions bazed on the available
informatioa
� O�
O :,� O
� ��� ' CITY of ORONO
r� r��ad r�'� �
�� ����` � !� Municipal Offices
` �, ti
�� � ������� �
.t ��`�'�'��'�`�`"_'�.� Street Address: Mailing Address:
aq "'I aV'`�i u' '¢,
kE8H0 2750 Kelley Parkway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: ���� I�.�t.�.�.�� Address: 170 Big Island
Permit #'s: 8325 Dates: 2/3/86 Contractors: Widmer Bros.
(This is [� an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil leval [XJ has or [ ] has not been idantified at this time. If the
saturated soil leval has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 5
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintanance Pumpout the tanks [ J were or [�J were not confirmed
to be watertight by the licensad pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subjact to ravision.)
INFIELD CONDITION (11-14) : 11
1 Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
i
la-�l�� �-----
Date of Inspec ion tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER ��� ISOIc;�'s ADDRESS �t'�'r�✓�iQ C�`r � �67 /JiGt �5�l�
PERMIT NO.'S. ����s DATES � ���� CONTRACTORS �✓rUt�✓� S�d�.
City Ordinance No, 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been i�spected and appears to fall into the category checked below.
(This is �, an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly,
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential tor future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle. (Does not
� Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in ta�ks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. shauld be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) �Adequate
❑ High water table �-Low Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge.
COMMENTS:
/Q-S%-`�'(� �'
Date of Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requireme�ts for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner