HomeMy WebLinkAboutP19-000072 - plumbing for dog kennelPERMIT PROJECT
FILE #: 19-000382
3800 SHORELINE DR WAYZATA MN 55391
INSTALL NEW PLUMBING SYSTEM FOR DOG KENNEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000072 Install new plumbing s...
Created On
06/03/2019 by Roger Peitso
Notes
Inspect tie into existing sewer
DATES
Date
06/03/2019
From
1: 00 PM
To
1: 30 PM
Completion Date
06/03/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 4 inch tied into existing clay tile , cleanouts at building and tie in. PVC contrasting cleaner used.
Looks good Okay to back ll.
PERMIT PROJECT
FILE #: 19-000382
3800 SHORELINE DR WAYZATA MN 55391
INSTALL NEW PLUMBING SYSTEM FOR DOG KENNEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000072 Install new plumbing s...
Created On
05/24/2019 by Anne Hentges
Notes
DATES
Date
06/05/2019
From
1: 30 PM
To
2: 00 PM
Completion Date
06/05/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 UG only PVC contrasting cleaner used 5 psi holding
Provide 5psi on entire system
PERMIT PROJECT
FILE #: 19-000382
3800 SHORELINE DR WAYZATA MN 55391
INSTALL NEW PLUMBING SYSTEM FOR DOG KENNEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000072 Install new plumbing s...
Created On
06/17/2019 by Anne Hentges
Notes
DATES
Date
06/25/2019
From
2: 30 PM
To
3: 00 PM
Completion Date
06/25/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Tied into UG PVC Contrasting cleaner used. Nail plates in place
0 5psi passed
PERMIT PROJECT
FILE #: 19-000382
3800 SHORELINE DR WAYZATA MN 55391
INSTALL NEW PLUMBING SYSTEM FOR DOG KENNEL
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000072 Install new plumbing s...
Created On
07/18/2019 by Anne Hentges
Notes
DATES
Date
07/25/2019
From
1: 00 PM
To
1: 30 PM
Completion Date
07/25/2019
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Manometer 1 1/2 inches of water column passed, xtures sealed.
0 T and P valve in place discharge okay. Back ow okay electricity not hooked up to water heater.