Loading...
HomeMy WebLinkAboutP19-000057 - plumbingPERMIT PROJECT FILE #: 19-000295 485 SANDHILL DR LONG LAKE MN 55356 ROUGH AND COMPLETE PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000057 Rough and complete plu... Created On 04/04/2019 by Nola Dickhausen Notes UG DATES Date 04/12/2019    From 1: 00  PM To 1: 30  PM Completion Date 04/12/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  100 DWV PVC Schedule #40 visual inspection Jason R.  PERMIT PROJECT FILE #: 19-000295 485 SANDHILL DR LONG LAKE MN 55356 ROUGH AND COMPLETE PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000057 Rough and complete plu... Created On 04/26/2019 by Nola Dickhausen Notes DATES Date 04/29/2019    From 2: 30  PM To 3: 00  PM Completion Date 04/29/2019 Status Correct Work & Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 AG DWV PVC sch 40. 5 lb air test is holding. 2 in accessible , removable trap provided for garage oor drains. Radon vented to exterior and insulated in attic. Finish water piping and insulate water lines. Correct and OK to continue. Jim H.  PERMIT PROJECT FILE #: 19-000295 485 SANDHILL DR LONG LAKE MN 55356 ROUGH AND COMPLETE PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Set & Seal   Assign To Nola Dickhausen Permit #: P19-000057 Rough and complete plu... Created On 06/25/2019 by Anne Hentges Notes DATES Date 06/28/2019    From 10: 30  AM To 11: 00  AM Completion Date 06/28/2019 Status Permit Finaled  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 ert# 1548107062 5/8" Rdg: 0000000.12 Water turned on - curb stop ok  PERMIT PROJECT FILE #: 19-000295 485 SANDHILL DR LONG LAKE MN 55356 ROUGH AND COMPLETE PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P19-000057 Rough and complete plu... Created On 07/08/2019 by Anne Hentges Notes DATES Date 07/10/2019    From 9: 30  AM To 10: 00  AM Completion Date 07/10/2019 Status Permit Finaled  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 Plumbing manometer is holding. Fixtures set and sealed. Water heater and TPR valve OK. 1. Lav and vanity not installed in 1/2 bath ML. 2. Provide testing by certied vacuum breaker installer and testing report for irrigation VB. Rest of work complete, correct and permit naled. Remove roof vent caps. Jim H. 