HomeMy WebLinkAboutP19-000052 - plumbingPERMIT PROJECT
FILE #: 19-000271
3175 JAMESTOWN RD LONG LAKE MN 55356
RELOCATE RI SINK W/ NEW KITCHEN FIXTURES, RELOCATE MAIN BATH DRAIN & CHANGE TUB RI TO SHOWER W/ NEW FIXTURES, RI NEW MASTER
BATH W/ NEW FIXTURES, RI 2ND FLR LAUNDRY, RI BAR SINK W/ FIXTURES, NEW FLR DRAIN, RELOCATE SILLCOCK
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000052 Relocate RI Sink w/ Ne...
Created On
03/20/2019 by Anne Hentges
Notes
DATES
Date
04/23/2019
From
2: 30 PM
To
3: 00 PM
Completion Date
04/23/2019
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Remodel and addition. DWV PVC sch 40 tied to existing ABS sch 40 with mission bands and to cast iron
hub with Fernco gasket. 5 lb air test is holding. Dog wash not connected UG at this time, contractor to
provide pictures. Relocate radon vent and reconnect to existing termanation with fan in attic.
1. Finish nail plates and insulate water lines.
Correct and OK to continue. Jim H.
PERMIT PROJECT
FILE #: 19-000271
3175 JAMESTOWN RD LONG LAKE MN 55356
RELOCATE RI SINK W/ NEW KITCHEN FIXTURES, RELOCATE MAIN BATH DRAIN & CHANGE TUB RI TO SHOWER W/ NEW FIXTURES, RI NEW MASTER
BATH W/ NEW FIXTURES, RI 2ND FLR LAUNDRY, RI BAR SINK W/ FIXTURES, NEW FLR DRAIN, RELOCATE SILLCOCK
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000052 Relocate RI Sink w/ Ne...
Created On
06/20/2019 by Anne Hentges
Notes
DATES
Date
06/26/2019
From
3: 00 PM
To
3: 30 PM
Completion Date
06/26/2019
Status
#STATUS COMMENTS
INSPECTION COMMENTS
0 Visual for AG water lines for dog wash in garage. Shut offs with bleeders located in LL mech room. Pex
water lines with insulation. 4 in radon vent relocated for remodel tied to existing vent in LL and to existing
fan in garage attic. Manometer for active radon system located in LL. OK to continue. Jim H.
PERMIT PROJECT
FILE #: 19-000271
3175 JAMESTOWN RD LONG LAKE MN 55356
RELOCATE RI SINK W/ NEW KITCHEN FIXTURES, RELOCATE MAIN BATH DRAIN & CHANGE TUB RI TO SHOWER W/ NEW FIXTURES, RI NEW MASTER
BATH W/ NEW FIXTURES, RI 2ND FLR LAUNDRY, RI BAR SINK W/ FIXTURES, NEW FLR DRAIN, RELOCATE SILLCOCK
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000052 Relocate RI Sink w/ Ne...
Created On
09/26/2019 by Anne Hentges
Notes
DATES
Date
10/04/2019
From
2: 30 PM
To
3: 00 PM
Completion Date
10/04/2019
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Fixtures trapped, supply shut offs, DW air gap
101 Fixtures set &and sealed