Loading...
HomeMy WebLinkAboutP18-000190 - plumbingPERMIT PROJECT FILE #: 18-001473 1335 ARBOR ST WAYZATA MN 55391 NEW HOME PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000190 New home plumbing  Created On 01/02/2019 by Anne Hentges Notes DATES Date 01/04/2019    From 3: 30  PM To 4: 00  PM Completion Date 01/04/2019 Status #STATUS COMMENTS   INSPECTION COMMENTS  0 Under ground ok  PERMIT PROJECT FILE #: 18-001473 1335 ARBOR ST WAYZATA MN 55391 NEW HOME PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000190 New home plumbing  Created On 01/22/2019 by Anne Hentges Notes DATES Date 01/22/2019    From 1: 30  PM To 2: 00  PM Completion Date 01/22/2019 Status Correct Work & Proceed #STATUS COMMENTS    INSPECTION COMMENTS  0 Under ground ok 0 Main level and out roof. Drain waste and vent is PVC schedule 40. 5 pound air test is holding. Radon is vented and insulated. 1. Provide permit card on site for all inspections, correct and OK to continue. Jim H.  PERMIT PROJECT FILE #: 18-001473 1335 ARBOR ST WAYZATA MN 55391 NEW HOME PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000190 New home plumbing  Created On 02/06/2019 by Nola Dickhausen Notes DATES Date 02/08/2019    From 2: 00  PM To 2: 30  PM Completion Date 02/08/2019 Status Correct Work & Proceed #STATUS COMMENTS      INSPECTION COMMENTS  0 Finish adding nail plates. Jason R. 100 DWV PVC Schedule #40 101 Water lines insulted 102 5# air test holding  PERMIT PROJECT FILE #: 18-001473 1335 ARBOR ST WAYZATA MN 55391 NEW HOME PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000190 New home plumbing  Created On 03/22/2019 by Anne Hentges Notes Floor Drain-Garage DATES Date 03/26/2019    From 1: 00  PM To 1: 30  PM Completion Date 03/26/2019 Status Correct Work & Proceed #STATUS COMMENTS       INSPECTION COMMENTS  0 Finish adding nail plates. Jason R. 0 UG garage oor drain. 2in. PVC. Not connected in mech. UG garage oor drain . 2 in. PVC sch 40 into house. Not connected at this time. 1. Provide removable trap. Access panel provided. Will check at plg. nal. Correct and ok to continue. Jim H. 100 DWV PVC Schedule #40 101 Water lines insulted 102 5# air test holding  PERMIT PROJECT FILE #: 18-001473 1335 ARBOR ST WAYZATA MN 55391 NEW HOME PLUMBING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P18-000190 New home plumbing  Created On 04/05/2019 by Nola Dickhausen Notes DATES Date 04/08/2019    From 2: 30  PM To 3: 00  PM Completion Date 04/08/2019 Status Permit Finaled  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 All xtures set and sealed manometer holding. seal sump pump basket and Provide inspection for irrigation vacuum breaker. will check at building nal. Jason R. 