Dear Owner of 120 BIG ISLAND:
This is a friendly reminder to all Orono property owners with non-compliant, on-site septic systems:
Septic System Upgrade Deadline is Fast Approaching
Beginning in the mid-1990s the City began to identify those septic systems that made use of trench
drainfields, a majority of which do not maintain the minimum required vertical separation above
seasonal water tables. Each existing system was subjected to soil borings to determine the seasonal
water table depth. When a system was identified as non-compliant, the owner was notified of the need
to bring the system into compliance and given several years to complete the upgrade.
The deadlines to upgrade were divided into whether or not the property was in the Shoreland District
(within 1000' of a lake or within 300' of a protected tributary stream). Properties in the Shoreland
District were given until December 31, 2007 to become compliant. Properties outside the Shoreland
area with non-compliant systems were allowed until December 31, 2010 to conform to the septic code.
The above noted property is located in the Shoreland District and needs to be updated before
December 31, 2007.
Don't wait until the last minute! The City is strongly recommending that property owners not wait
until the deadline arrives to bring their systems into compliance. The process to upgrade your septic
system can be quite lengthy. The first step in the process is to hire a site evaluator and designer to
determine what type of system is required and provide the blueprint for the system installation.
Secondly, the property owner must then contract with a septic system installer to have the system
constructed.
The installation of a septic system is very weather dependent, especially for mound systems, which can
only be installed when the ground is relatively dry, i.e. typically June through September. Contractors'
schedules fill up quickly, so it's important to start your planning and design process now to ensure a
timely installation. The period of time from deciding to update your septic system to the actual
installation can easily exceed three to four months, or more. Please contact the Building and Zoning
Department at 952-249-4600 with any questions you may have about bringing your septic system into
compliance.
For a list of licensed designers and installers you may go to www.ci.orono.mn.us, click on
City Departments, click on Septic, then click on the link to www.pca.state.mn.us.
Telephone (952) 249-4600 • Fax (952) 249-4616
www.ci.orono.mn.us
i
� .
� O�
O�;;�� O
��'�`::�� CIT�'of O�t011T0
.y.x.;�,�
4;�...
i �t. ��
� � �� ` �
���+^ �� ti
h-:�
,� ��,I'"���'����� '�' Municipal Offices
� ��'��'`�-���`�`�� Street Address: Mailing A�dress:
,q �i.r�li �,
. kEg$O 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay; MN 55323-0066
Owner: Sah� U �'y^ Address:_ �a� Q�q �S�4�r�
Cit��Ordinance 199 requires that each exisUng on-site se�vage treatrnent system in Orono be inspectec3 every hvo years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.'
SYSTEti1 CONFORMITY (1-3): 3
1 ��CODE SYST'EM" An ISTS which meets all the location,design and construction seandards of the current Qrono bfunicipal Coda.
2 °CO?�TPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standarcis ofthe current Orono Municipal
Code but does meet the three foot separation requuemen�and which is not failing or an imminent thrzat to public heahh ot safety.
O3 °NON-CO�SPLIANf SYSTEM" Aprohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
or may net meet all the localion,design,or construction standazds of the cunent Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three fzet of unsaturatad soil or sand betwezn the distribution device and the luniting soil characteristics.
TANK CONDITION(�-10): 9 �
Tanl:inspection indicates:
� Pumpout not nzedzd at this time.
6 Tank must be pumped out this year (city code requires tanks to be pumpzd out evzry 3 years. Tank was last pumped_ ),
7 Solids accumulation in tanks is at a critical a critical leve(. Tanks should be pumped out as soon as possibla.
8 Systzm is discharging to thz surFace. Tanks must be pumped out within 48 hours to eliminatz surface discharge.
� Inspe:tion riszrs missing-tanks cou(d not be inspzctzd. Inspection risers(4"dia.pipe)must be instailzd in each tank at nzat pumpout Iftanks
havz no[bezn pumpzd out within the last three years,they should be pumpzd out now.
10 Inspzction pipz is located directly over tank baffle(does not give accurate measurement of solids accumulation). Iftanks have not been pumped
out within the last thrze years,they should be pumped out now. .
DRAINFIELD COVDITION(11-14): � �
11 Drairttield is dry,no surfacing eviden�
12 Some zvidznce of surfacing not crilical yet � ,
13 Dr�infield is saturated and visibly dischazging untreated e$luent to the surfacz. Contact the City Inspector irnmediately.Rrpairs must be
completad�ithin 90 days.
1� Drainfield estent and condition unknown.
CO1��IENTS:_ SYS-reM �oes nofi meefi -Foo�- Seper'Rfi,o� d",stq�c-c �epq r
by �a- 3�- o�.
5- �3 —ot �a�z
Date of Inspection Seplic System Inspector
Note: In the event that this inspectioa report is tued to satisfy the requuemenLs for a moRgage or other transfer of property,be advued that this report does not guazantee
or crrtify tfiat an esisting systzm will coatinue to function properly,but is merely an opinion of the adequacy of the system under curre�conditions based on the available
informalioa
� o�
o .�A o
� CI7rY of ORONO
.� �E a��j� �,�'.�. �
�,, � �° ��, -�� �f� Municipal Offices
� ���� �I��r�� G
.��' ���'�i�y,, ��.� Street Address: Mailing Address:
�C'E$g0 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: � / 1 � Address:120 Big Island
Permit #'s:5916 Dates:2/7/80 Contractors:A. L. Bragelman
(This is � an existing system [ ] new construction)
SYSTEM COMPLIANCE (1-3) : 3
1 Code Svstem: Meets or exceeds current City standards in all respects relating to
design, construction, and location. Appears to be operating properly.
2 Co_mpliant Svstem: Does not meet all current City standards for new construction,
but in most respects appears to be designed, located, and constructed in accordance
with previous codes and is functioning properly.
� Non-Compliant Svstem: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the
current input; and any system with less than three feet of vertical separation
between the bottom of the drainfield and the saturated soil level .
(The saturated soil level � has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION 5-9 : 5
5 Pumpout not needed at this time
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been
pumped out within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If
tanks have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or [�(] were not
confirmed to be watertight by the licensed pumping contractor. If the tanks were not
confirmed to be watertight, this classification is subject to revision. )
D INFIELD CONDITION 11-14 : 11
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system acTe and condition, soils, etc. ) : medium
COMMENTS: The non-compliant septic system must be repaired by 12/31/98 or within 90 days
of failure (surface discharge) , whichever comes first.
lc��� -� ' �
Date of pection ep c System Ins ector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue
to function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER . �(>�!`i (JYQ11 ADDRESS _Kfi?� Lf3'��"�'�� .L��/Gl�
PERMIT NO.'S. ���� DATES �-7�r�� CONTRACTORS ` �" �
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is �an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design, construction or locatio�, but is failing to properly treat and
dispose of the current input, and is e�dangering a water supply,or is a source of pollution to surtace or groundwaters,or is
creating a safety hazard, or is otherwise creating a public nuisance.P�ease contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not
� Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Fiepairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Futur Expansion
❑ Soil table,and system condition) �Adequate
❑ High water table � Low ❑ Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge.
COMMENTS:
%�3�`3� >
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner