HomeMy WebLinkAboutP18-000124 - replace 2 water heatersPERMIT PROJECT
FILE #: 2017-01664
30 LUCE LINE MAPLE PLAIN MN 55359
MECH RESI MMEC
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000124 replace 2 waterheaters
Created On
09/21/2018 by Nola Dickhausen
Notes
DATES
Date
09/26/2018
From
3: 30 PM
To
4: 00 PM
Completion Date
09/26/2018
Status
Inspection Failed: Reinspect
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Two water heater replacement reinspection. Venting correction provided, natural draft venting for both.
Saddle valve replaced with in-line soldered ball valve. Water heaters in room with three furnaces, all
drawing combustion air from interior. 1. Provide combustion air per code and call for reinspection. Jim H.
PERMIT PROJECT
FILE #: 2017-01664
30 LUCE LINE MAPLE PLAIN MN 55359
MECH RESI MMEC
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
Created On
10/24/2018 by Anne Hentges
Notes