HomeMy WebLinkAboutP18-000082 - plumbingPERMIT PROJECT
FILE #: 18-000692
785 FERNDALE RD WAYZATA MN 55391
REPLACE WATER HEATER
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000082 REPLACE WATER HEATER
Created On
07/27/2018 by Anne Hentges
Notes
Michelle 612-306-5488
DATES
Date
07/31/2018
From
11: 00 AM
To
11: 30 AM
Completion Date
07/31/2018
Status
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Gas water heater replacement. Existing gas line and natural draft venting. Provide combustion air or
calculations for Code complying fresh air in room. Water heater and one furnace drawing combustion air
from inside mechanical room. Correct and call for reinspection. Jim H.
PERMIT PROJECT
FILE #: 18-000692
785 FERNDALE RD WAYZATA MN 55391
REPLACE WATER HEATER
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000082 REPLACE WATER HEATER
Created On
09/04/2018 by Nola Dickhausen
Notes
DATES
Date
09/07/2018
From
10: 00 AM
To
10: 30 AM
Completion Date
09/07/2018
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Venting was changed on furnace to draw combustion air from outdoors water heater is now the only
appliance using indoor combustion air