HomeMy WebLinkAboutP18-000080 - plumbingPERMIT PROJECT
FILE #: 18-000683
1795 FOX ST WAYZATA MN 55391
NEW HOUSE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000080 new house
Created On
07/30/2018 by Nola Dickhausen
Notes
UG
DATES
Date
08/01/2018
From
9: 00 AM
To
9: 30 AM
Completion Date
08/01/2018
Status
#STATUS COMMENTS
INSPECTION COMMENTS
0 Underground drain waste and vent is PVC schedule 40. 5 pound air test is holding. Underground water
lines are insulated. Sewer will drain to septic system. Radon to be vented out of lower sump basket. OK to
continue. Jim H.
PERMIT PROJECT
FILE #: 18-000683
1795 FOX ST WAYZATA MN 55391
NEW HOUSE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000080 new house
Created On
09/10/2018 by Anne Hentges
Notes
DATES
Date
09/11/2018
From
1: 30 PM
To
2: 00 PM
Completion Date
09/11/2018
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Above ground drain waste and vent is PVC schedule 40. 5 pound air test is holding.1. provide structural
strap lower level top plate for vent for bar sink. 2
PERMIT PROJECT
FILE #: 18-000683
1795 FOX ST WAYZATA MN 55391
NEW HOUSE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
Created On
12/18/2018 by Nola Dickhausen
Notes
DATES
Date
12/19/2018
From
9: 00 AM
To
9: 30 AM
Completion Date
12/19/2018
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
100 Manometer holding
101 Fixtures set &and sealed
102 Remove roof caps