0 Underground drain waste and vent is PVC schedule 40. Backwater valve provided. Five pound air test is
holding. OK to cover. Jim H.
PERMIT PROJECT
FILE #: 18-000575
2340 OLIVER HILL LONG LAKE MN 55356
INSTALL PLUMBING FOR 4 BATH, KITCHEN, LAUNDRY- FULL BATH R/I ONLY AND BAR R/I ONLY. WATER HEATER FLOOR DRAIN SUMP PUMP AND
IRRIGATION LINE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000067 Install Plumbing for 4...
Created On
08/03/2018 by Anne Hentges
Notes
Dan 763-607-0621
DATES
Date
08/07/2018
From
11: 30 AM
To
12: 00 PM
Completion Date
08/07/2018
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Drain waste and vent is PVC schedule 40. 5 pound air test is holding. Waterlines are insulated. Radon
vented out of sump basket. 1. Provide structural straps on all loadbearing walls containing plumbing
stacks or vents, contractor providing at time of inspection. Correct and OK to continue. Jim H.
PERMIT PROJECT
FILE #: 18-000575
2340 OLIVER HILL LONG LAKE MN 55356
INSTALL PLUMBING FOR 4 BATH, KITCHEN, LAUNDRY- FULL BATH R/I ONLY AND BAR R/I ONLY. WATER HEATER FLOOR DRAIN SUMP PUMP AND
IRRIGATION LINE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000067 Install Plumbing for 4...
Created On
11/01/2018 by Anne Hentges
Notes
dan 763-607-0621
DATES
Date
11/07/2018
From
3: 30 PM
To
4: 00 PM
Completion Date
11/07/2018
Status
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Plumbing manometer not holding.Fixtures are set and sealed. No irrigation vacuum breaker at this time.
1. Provide vacuum breaker on hose bib at pressure tank. Correct and call for re inspection. Jim H.
PERMIT PROJECT
FILE #: 18-000575
2340 OLIVER HILL LONG LAKE MN 55356
INSTALL PLUMBING FOR 4 BATH, KITCHEN, LAUNDRY- FULL BATH R/I ONLY AND BAR R/I ONLY. WATER HEATER FLOOR DRAIN SUMP PUMP AND
IRRIGATION LINE
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000067 Install Plumbing for 4...
Created On
11/07/2018 by Nola Dickhausen
Notes
Mike 612-369-7916
DATES
Date
11/08/2018
From
1: 00 PM
To
1: 30 PM
Completion Date
11/08/2018
Status
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 Manometer holding. boiler drain on pressure tank Falls under well installers scope of work. will check at