HomeMy WebLinkAboutP18-000061 - plumbingPERMIT PROJECT FILE #: 18-000524 2635 CASCO POINT RD WAYZATA MN 55391 NEW PLUMBING FOR NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000061 New Plumbing for New Home  Created On 07/03/2018 by Nola Dickhausen Notes UG Courtney 612-328-7790 DATES Date 07/11/2018    From 2: 00  PM To 2: 30  PM Completion Date 07/11/2018 Status #STATUS COMMENTS   INSPECTION COMMENTS  0 Underground drain waste and vent is PVC schedule 40. Backwater valve provided. Five pound air test is holding. OK to continue. Jim H.  PERMIT PROJECT FILE #: 18-000524 2635 CASCO POINT RD WAYZATA MN 55391 NEW PLUMBING FOR NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000061 New Plumbing for New Home  Created On 07/11/2018 by Nola Dickhausen Notes Garage PERMIT PROJECT FILE #: 18-000524 2635 CASCO POINT RD WAYZATA MN 55391 NEW PLUMBING FOR NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000061 New Plumbing for New Home  Created On 08/01/2018 by Nola Dickhausen Notes DATES Date 08/01/2018    From 2: 30  PM To 3: 00  PM Completion Date 08/01/2018 Status Correct Work & Proceed #STATUS COMMENTS   INSPECTION COMMENTS  1 Above ground drain waste and vent is PVC schedule 40. Radon vent is OK. Five pound air test is holding. Main level and upper-level waterlines OK. Finish water lines in lower level and OK to continue. Jim H.  PERMIT PROJECT FILE #: 18-000524 2635 CASCO POINT RD WAYZATA MN 55391 NEW PLUMBING FOR NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P18-000061 New Plumbing for New Home  Created On 11/27/2018 by Anne Hentges Notes courtney 612-328-7790 DATES Date 12/04/2018    From 2: 30  PM To 3: 00  PM Completion Date 12/04/2018 Status  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 Plumbing manometer is holding. No kitchen sink at this time. Master bath tub not set at this time. Upper level laundry and bath to be un PERMIT PROJECT FILE #: 18-000524 2635 CASCO POINT RD WAYZATA MN 55391 NEW PLUMBING FOR NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Set & Seal   Assign To Nola Dickhausen Permit #: P18-000061 New Plumbing for New Home  Created On 12/21/2018 by Nola Dickhausen Notes DATES Date 12/11/2018    From 9: 00  AM To 9: 30  AM Completion Date 12/11/2018 Status  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  1 ERT 1548806618 1" Rdg 00000003 