HomeMy WebLinkAboutP18-000028 - plumbingPERMIT PROJECT
FILE #: 2017-01591
1140 WYNDMERE RD WAYZATA MN 55391
NEWS RESI SING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000028 new house ground up r...
Created On
05/18/2018 by Anna Carlson
Notes
Underground Rough In -
Marvin
763-614-8310
DATES
Date
05/21/2018
From
8: 30 AM
To
9: 00 AM
Completion Date
05/21/2018
Status
#STATUS COMMENTS
INSPECTION COMMENTS
0 Underground drain waste and vent is PVC schedule 40. 5 pound airtest is holding. Sanitary will go to septic
system. Radon to be vented out of sump basket. 4 inch clean out to be located on outside of house. OK to
cover. Jim H.
PERMIT PROJECT
FILE #: 2017-01591
1140 WYNDMERE RD WAYZATA MN 55391
NEWS RESI SING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000028 new house ground up r...
Created On
05/31/2018 by Melanie Curtis
Notes
Above ground
763-614-8310
DATES
Date
06/05/2018
From
2: 30 PM
To
3: 00 PM
Completion Date
06/05/2018
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Upper level and main level drain waste and vent is PVC schedule 40. 5 pound air test is holding. 1. Provide
structural strap for top plate cut for vent in loft bathroom. 2. Insulate all hot water lines three-quarter inch
and larger and half inch lines 25 feet from manifold. 3. Label radon vent. 4. Finish nail plates. Will check
corrections at lower level rough in inspection. Correct and OK to continue, Jim H.
PERMIT PROJECT
FILE #: 2017-01591
1140 WYNDMERE RD WAYZATA MN 55391
NEWS RESI SING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P18-000028 new house ground up r...
Created On
06/25/2018 by Nola Dickhausen
Notes
Basement
Marvin 763-614-8310
DATES
Date
06/26/2018
From
3: 00 PM
To
3: 30 PM
Completion Date
06/26/2018
Status
Correct Work & Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 Plumbing rough in for lower level. Above ground drain waste and vent is PVC schedule 40. Five pound air
test is holding. 1.
PERMIT PROJECT
FILE #: 2017-01591
1140 WYNDMERE RD WAYZATA MN 55391
NEWS RESI SING
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P18-000028 new house ground up r...
Created On
12/06/2018 by Anne Hentges
Notes
marvin 763-614-8310
DATES
Date
12/10/2018
From
3: 00 PM
To
3: 30 PM
Completion Date
12/10/2018
Status
Permit Finaled
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 plumbing manometer is holding. 1. Finish setting and sealing all