Loading...
HomeMy WebLinkAboutP18-000028 - plumbingPERMIT PROJECT FILE #: 2017-01591 1140 WYNDMERE RD WAYZATA MN 55391 NEWS RESI SING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000028 new house ground up r... Created On 05/18/2018 by Anna Carlson Notes Underground Rough In - Marvin 763-614-8310 DATES Date 05/21/2018    From 8: 30  AM To 9: 00  AM Completion Date 05/21/2018 Status #STATUS COMMENTS   INSPECTION COMMENTS  0 Underground drain waste and vent is PVC schedule 40. 5 pound airtest is holding. Sanitary will go to septic system. Radon to be vented out of sump basket. 4 inch clean out to be located on outside of house. OK to cover. Jim H.  PERMIT PROJECT FILE #: 2017-01591 1140 WYNDMERE RD WAYZATA MN 55391 NEWS RESI SING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000028 new house ground up r... Created On 05/31/2018 by Melanie Curtis Notes Above ground 763-614-8310 DATES Date 06/05/2018    From 2: 30  PM To 3: 00  PM Completion Date 06/05/2018 Status Correct Work & Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Upper level and main level drain waste and vent is PVC schedule 40. 5 pound air test is holding. 1. Provide structural strap for top plate cut for vent in loft bathroom. 2. Insulate all hot water lines three-quarter inch and larger and half inch lines 25 feet from manifold. 3. Label radon vent. 4. Finish nail plates. Will check corrections at lower level rough in inspection. Correct and OK to continue, Jim H.  PERMIT PROJECT FILE #: 2017-01591 1140 WYNDMERE RD WAYZATA MN 55391 NEWS RESI SING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P18-000028 new house ground up r... Created On 06/25/2018 by Nola Dickhausen Notes Basement Marvin 763-614-8310 DATES Date 06/26/2018    From 3: 00  PM To 3: 30  PM Completion Date 06/26/2018 Status Correct Work & Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Plumbing rough in for lower level. Above ground drain waste and vent is PVC schedule 40. Five pound air test is holding. 1. PERMIT PROJECT FILE #: 2017-01591 1140 WYNDMERE RD WAYZATA MN 55391 NEWS RESI SING  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Permit #: P18-000028 new house ground up r... Created On 12/06/2018 by Anne Hentges Notes marvin 763-614-8310 DATES Date 12/10/2018    From 3: 00  PM To 3: 30  PM Completion Date 12/10/2018 Status Permit Finaled  Erosion Control Checked, Found Compliant #STATUS COMMENTS   INSPECTION COMMENTS  0 plumbing manometer is holding. 1. Finish setting and sealing all