HomeMy WebLinkAboutSeptic info %�/ � O�\\
' \�
,; � � �,.
�� -
�� CITY of ORONO
� ,,a ��j�, _ - ;
�i � , _t � ;
�\",�',, �"�',.'�.: � �' /� Municipal Offices
}
� �.�;��.~:���;r .�� 'ti,i;
� ,.;)';'.-�.'�`_r G '
t _ , �/� Street Address: Mailing Address:
9�CE`g�'% 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0o66 .
_ _____ __ ______ ___ _______ 1
To Current Owner: Address: y�y� u''��s�G�� ��
City Ordinance 199 requires that each existing on-site se�vage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked belo�r�.
SYSTEM CONFORMITY (1-3): S
1 "CODE SYSTEM" An ISTS which meets all the location,desi�n and construction standazds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municip�I
Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failina or
�`\ an imminent threat to public health or safety. '
( .i � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within_a designated 100-year flood plain,any ISTS which may
�J or may not meet all the loca[ion,design,or construction s[andards of[he current Orono Municipal Code and which is failing for any reason:s,d
any ISTS with less than three feet of unsaturated soil or sand between[he distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): �
Tank inspection indicates:
� Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped � -1�1-C�L- ).
Make sure seatic tanks are pumaed throu�h manhole and not through white inspection pipes This allows for the
proper cleaning. Keep water softner and iron filter discharge out of seatic svstem.
7 Inspection risers missin�-tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out no�v.
DRAINFIELD CONDITION 8-10 : �
8 Drainfield is dry, no surfacin�evident.
9 Some evidence of surfacins,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
COMMENT�: S�C S� ��,c,-��_ J�C �.,�C:�\1 ,S l�t;��_ C o�-�'�`�^� n�� �ul k �t
S :.Q���Ccn � � IZ_ -�\ " �-Ci0 �� ,�p 1-�.,.\C) G�tL Z�IPc-r Z=� �Z<,iJ ,
��\�5'��5 �`f�--� ���-.
Date of Inspection NSatt Boltecman - Septic System Inspector
Note: In[he event that this inspection report is used to satisfy the requirements for a mortgage or other Vansfer of property,be advised that this report does not guarantee
or certify that an existin�system will continue to function properly,but is merely an opinion of the adequacy ofthe system under current conditions based on the a�ailable
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
----- -
� � _ v
�� � O .�I`,
;; ,, ; , � ;, CITY of OIZOl�O
� ' ` �C,, ,r' Municipal Offices
�� 1 ' � . �,�
Street Address: Mailing Address:
L`q.kEgKp4'� 2750 Kelley Parkway P.O. Box 66
-_- - Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Cunent Owner of Address ��`�� ��4�-{ 5. c�
City Ordinance requires that onsite sewa�e treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identif as Non-Compliant
Yes
No �
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010 �
Other
Septic Tank s Pump out Needed
Yes
No
The City recommends the septic tar�k(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
�,�- ( �( -0 � . The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning.
Comments:
� �� �, � �
Insp�� Date of Inspection � � "C -�
'Telephone(9�2) 249-4600 � Fax (9�3) 249-4616
u�ww ri nrnnmm�.nc
. � °�
, o_::::. o �
, ��y�.::.�._� ciTYof o�oNo
�3 �;`����t:�'�:� ,,,,
'� ;�` �-',�,.� . .
+ ;�L:1�'`� ,�,�' Municipal Offices
'� �;;;.�:/ ��,�:,�
"''"�`°`����� G Street Address:
'Z j ��,���i�• • '� MailingAddress: �
�kE$H�g 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crysta( Bay, MN 55323-0066
Owner: � ��c�c� �Q�S',c�� �d .
Address:_ 4�4� �
Ciry Ordinance 199 requires that each existing on-site setivage treatment system in Orono be inspected every tc,vo yeazs.
The on-site se�vage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORNIITY (1-3�: 3
1 °CODE SYSTEM° An ISTS which meets all the location,design and coastruction standards ofthe current Orono I�funicipal Codz.
2 '�COivII'LIANT SYS'I'EM�� An ISTS which does not maet a11 the localion,desigt and construction standards ofthe currrnt Orono Municipal
Codz but dors meet tha three foot sepazation requiremen;and which is not failing or an imminent threat to public health ot safzty.
�3 "NON-CONLPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a dzsignatzd 100-year flood plaiq any ISTS which may
or may not mzet all the location,design,or construction staadards of the currerrt Orono Nlunicipal Code and which is failing for any reasoa;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics.
TANI�CONDITION(�-101: 6 .
Tanl:inspection indicates: •
� Pumpout not needed at this time.
� Tanl:must be pumpzd out this year (city codz requires tanks to bz pumped out every 3 years. Tank was last pumped 6-►?-q 6 �
7 Solids accumulation in tanks is at a critical a criticallavzL Tanks should be pumped out u soon as possible.
8 System is discharging to the surface. Tanks must be pumpzd out within 48 hours to eliminatz surfacz discharge.
9 Inspection riszrs missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be instal(ed in each tank at next pumpouL Iftanks
hlve not been pumped out within the last three years,they should be pumped out now.
1� Inspectiun pipe is located dirzctly over tank baHle(does not give accurate measurzment of solids accumulation). If tanks have not beenpumped
out�vithin tha l�st thrze ycars,they should be pumped out no�v.
DRAINFIELD CO�IDITION(11-14): �
11 Drainfietd is dry,no surFacing eviden[.
12 Some zvidence of surfacing,not critical ye� . � ' '
13 Drainfield is saturated and visibly discharging untreated efflurnt to the surface. Contact tha City Inspector immediately.Repairs must be
completed�sithin 90 days.
1=� Drainfield e�Zznt and condition unknown
COMI�IENTS: S�f 5-�-e � r��S�- bt re�Jlqce� b� ►�.-31-�-0�o sxs-t-�,� does
h l� ��.2-� o-� 5 P D(/bt-�-�a n d 31��<< -
6—�—a� (,1�,.��c
Date of Inspeccion Sepfic System Inspector {
Note: In the event that this inspection report is used to satisfy the requuements for a mortgage or otfier transfez of property,be advised that tfiis repoR does not guarani�e
or czrtify that an esisting system will continua to function properly,but is merely an opinion of the adequacy of the systnn under current conditions baszd on the availabta
infocmalioa
CITY OF ORONO � O�
Municipal Offices O O
Post Office eox 66
Crystal eay, MN 55323-0066 � � ON–SITE SEWAGE TREATMENT
r$), � INSPECTION REPORT
'C�� G~
9kESH��'�
/� /l � �
Owner:�Ji �� 4/G��1!'l, ����Q����Address: �"f7''�Q �l�l��'l� (C�c 5S�',5��
Permit �'s: �`7(� y�s Dates: Sl�`����, ��ay/�7 Contractors:�1%'°G��'>1t 2 �•t�, , �- ��J� �7t=.j��'LSGY1 �c�.
,
City ordinance number 100 requires that each on-site seuage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked belou.
(This is � an existing system [ ] neu construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface uaters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging
any pollutants �nto ground or surface Waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet atl the location, design, and construction standards of the current City
Codes and uhich is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic�has or [ 7 has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
Solids accumulation in tanks is at a critical level. Tanks should be purnped out as soon as possible.
8 System is discharging to the surface. Tanks must be pwnped out uithin 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next purtipout. If tanks have not been pixnped out Within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out uithin the last three years, they should be pumped out noW.
DRAINFIELD CONDITION (11-14):
Dr ' ield inspection indicates:
1 rainfie[d is dry, no surfacing evident.
2 Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
imnediately. Repairs must be canpleted within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (stope,setbacks,etc.): ..—��
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.>: %nnL A�u�y�
yy
COMMENTS: S, /S -Ci Z w( � � Gx� ((•'r�� G' GtJ 1Y�1'� fL'��'f'
S� r'4 ra�✓�Y�
�. , � , r - h/e 3� : .� �
h� 2- -2 c.Y. ^
Date of Inspe tion Sep ic Sys em Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises uith the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
� o�
o ���_ o
��=�������-�� CITY of ORONO
,���,j _
� � ����' �.� �
�, �,'� ,'��� , �r Municipal Offices
� ��r,�,���I;-��:��� G�'
� !�1,:��'7��<a�� ,� Street Address: Mailing Address:
.9 ��i�,�$'(i �,
$EgKO 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: �� M_ �r� �1� Address: 4740 Bayside Rd.
Permit #'s: 5990, 4851 Dates: 5/19/S0, 6/29/77 Contractors: Widmer Bros., E. J. Peterson
Co.
(This is [Y] an existing system [ ] new construction) .
SVRTF.M COMP IANCE (1-3) : 3
1 Code Sxstem: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 ComAliant S�stem: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
� Non-Com�liant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level [//] has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this clasaification is subject to revision.)
5
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanka [ ] were or [ t.�j� were not confirmed
to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subject to revisioa.)
- 4 : 11
11 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTFNTTAT F�R SYSTEM FAILURE• (system aqe and condition soils etc.) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 0 feet and the system is non-compliant. R pa' or repla m nt of the septic
system is required by 12/31/2007. ��+ �� �
r
Date of Inspection ptic System Inspector
Note: In the event that this inspection report is use to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
�t9kESH�4�G
Owner• ,� Address•�� ��1��� /(�
Permit #'s: 6J ��� Dates: /� — -`� Contractors: �,. ), �'E�7f'�SOV`� �N,Il��r
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �1, an existing system [ ] new construction)
SYSTEM CONfORMITY (1-3):
1 "CODE SYS7EM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or �has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): �
T�k inspection indicates:
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. lf tanks have not been pumped out within the last three years, they should be pumped
out now.
10 lnspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr nfield insPection indicates:
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector
imnediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
IIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): lRa'ii.�-Y��
COMMENTS:
,J�� -_
Date of Inspection Sep ic Syst m Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises with the system loc�ti�n and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore of
Lake Nlinnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER �� � / ADDRESS � L �
PERMIT NO.'S. �S �— DATES � ��7/ /�����'Q CONTRACTORS �,�'�� m''G�
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
IThis is �. an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly;no major
upgrading of the system is required at this time.
❑ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in ta�ks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. �"Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drai�field is saturated and visibly discharging untreated
� Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipeTmu�tie ir�� %+��p�^ti*��k ment or additions to drainfield. Contact the City Inspector
at next pumpout. If�anTc's'fi'ave no bet en pumped out within immediately.Repairs must be completed within 90 days.
SMe�aSTLIST�s,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansio�
❑ Soil table,and system condition) � Adequate
❑ High water table ❑ Low -�Fair
❑ Lot size �Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge.
COMMENTS:
b-�-�g- `�/ �--�
Date of Inspection S tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner