HomeMy WebLinkAboutSeptic info _ ._ _._._ _
� ��
/ � O\1�``��
;' '�;'�� CITY of OIZUNU►
�, j
, � � �`
� � � + , ti i Municipal Offices
�r '
�'' Street Address: Mailing Address:
'�` '� ��, C� ,
�`q.kEsHp4'� 2750 Kelley Parkway P.O. Box 66
` - -- - Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Current Owner of Address ������� f�,l�`� S ' � ��
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the followina is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes �No
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
Other
Septic Tank ump out Needed
Yes
No
The City recommends the septic tank(s) and/or lift tanlc be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
'/�zb ��C�r 1? , The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleanina.
Comments:
��� ,J r ��_ <' �
� ' ;9 ;, �� � � r � -o S-
Inspe r: y Date of Inspection
Telephone(9�2) 2�9-4600 � Fax (9�Z) �49-4616
u�a•wri nrnnn_mn.nc
/ o
,, � �
;;%o o ���
;� -;;�;��;�.�- ;; CITY of ORONO
,�� �.,- ri ��, �,�,
,`� ��,i'��',,l��:.,if^:}� G,�l�, / bfunicipal offices
��� i.,V' _;k,t r �
� _ �/ Street Address: Mailing Address:
\.Eg� 2750 Kelley Parkway P.O. Box 66
Orano, MN 55356 Crystal Bay, MN 55323-0066 .
---------------___-------
To Current Owner: Address: � b�� f�`�ys.-�t- �(.�
City Ordinance 199 requires that each existin�on-site sewa�e treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected zad a�pears to fall into the categories checked below.
STEM CONFORMITY 1-3 : �
"CODE SYSTEM" An ISTS which meets all the location,design and constructicfl staa,�3�ds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet ail ttx location,desi�and conswction standazds of the current Orono Municipal
Code but does meet the three foot separation requirement or two fcot requirement:or s}s�rms installed 1996 or earlier,andµhich is not failin�or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS(ocated within3 des:�ated 100-year flood plain,any ISTS«hich may
or may not meet all the loca[ion,desi;n,or construction standards of the current Orone viunicipai Code and which is failins for any reason;and
any ISTS with less than three feet of unsaturated soil or sand benc::n the distrib�,ron�.ice and the limiting soil chazacteristics.
TANK CONDITION(5-7): �
Tank inspection indicates:
5 Pumpout not needed at this time.
6� Septic tanks must be pumped out this year (city code requires tanks tr be F�umped out once every 3 years.
Tank was last pumped `�_ ).
Make sure seatic tanks are aumned through manhole and not through white inspection pipes This allo���s for the
proper cleanin�. Keen water softner and iron filter discharae out of septic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection rL:.rs(d" dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three year,they shou_'d be pumped out now.
DRAI�IFIELD CONDITION 8-10 : �
8 Drainfield is dry, no surfacing evident.
9 Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly dischar�in�untreated ef�luent to th�suriace. Contact the City Inspector
immediately. Repairs must be completed within 90 days_
COMMENTS: S�b S-,;c�,c.,,� ,��.��� \ ��_��j p�� f��'M� St� �L
— �t'�h�-� b�C� '��C Lr'—( � y e c�(�
�'\� �C^� J��� 1' �%�.�-V--��
Date of Inspection tifa`Bolt�.�-man - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or o*_`er tr�fer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an epinion ofthe a'.equa��of the system under current conditioas based on the a�ailable
information.
Telephone(952)249-4600 • Fax(9:2)2�9-4616
w�ww.ci.orono.mn.us
� � °�
, o 0
; -�-=:�:::��-� CIZiY of �RON4
, �-��:�• � �
�� .. 1.�.
r;
;�� S``,��`�'���'�:� ,�,�, . Municipal Offices
�' `'!�i�'
,L „�;•,,�:�• . .��.<'y G
� ,�,..�'�,-;�.� �y Street Address: Mailing Address:
�kEg$��' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: M �(_,��2� s IC.'�en Address: 46�Sa QayS�,d� P�d �
Ciry Ordinance 199 requires that each existing on-site setivage treatment system in Orono be inspected every rivo years.
The on-site se�vage treatment system at the above address has been inspected and appears to fall into ihe categories checked belo�v.
SYSTEM CONFORMITY (1-3): 1
Ol '�CODE SYSTEM�� An ISTS which meets atl the location,dzsign and construction standards ofthe current Orono bfunicipal Code.
2 ��COivIPLIANT SYSTEM" An ISTS which does not meet all thz location,design and constcuction standards of the currrnt prono hfunicipal
Code but does meet the three foot separation requiremen�and which is not failing or an immineat threat to public health or safzty.
3 ��NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a d�.signatzd 100-year flood plaia,any ISTS which may
or may not meet all the location,design,or construction standazds of the current Orono Nlunicipal Coda and which is failing for any reason;and
any ISTS with less than three feet of unsaturatzd soil or sand between the distribution device and the limiting soil chazactzristics.
TAM�CONDITION(5-10): 6 .
Tanl:inspection indicates: -
� Pumpout not nzeded at this time.
� Tank must be pumpzd out this year (city coda requires tanks to be pumped out every 3 years. Tank was last pumped v(�ICn D�v^ ),
7 Solids accumulation in L1nks is at a critical a critical level. Tanks should be pumped out as soon u possible.
8 S}�stem is discharging to the surface. Tanks must be pumped out within 48 hours to eliminatz surfacz discharge.
9 Inspzction risers missing-tanks could not be inspectzd. Inspection riszrs(4"dia.pipe)must be installzd in each tank at nzxt pumpout If tanks
hava not bezn pumpzd out within the last three years,they should be pumped out now.
10 Inspection pipz is locatzd directly over tank baffte(dozs not give accurate meazurzment of solids accumulalion). Ifk�nks have not been pumped
out�vithin the lut thrze years,they should be pumped out now.
DRAINFIELD COiVDITION(11-14): ��
11 Drai�zld is dry,no surfacing evident
1� Some avidence of surfacing,not critical ye� � '
13 Drainfield is saturatzd and visibly discharging untreatzd eHluent to the surface. Contact the City Inspector irnmediataly.Repairs must bz
completzd«ithin 90 days.
1� Drainfield zstznt and condilion unknown
CO�tiTi�NTS: 5 y STe n. , S o IC p v„-,� 1-a�k S
�-� -a � �� �_
Data o£Inspeccion Septic System Inspector � �
Note: In the event that this inspeciion repoR is used to satisfy the requuements for a mortgage or other tracufer of property,be advised that this repoR does not guarantga
or certify that an esiscing system will continue to function properly,but is merely an opinion of the adequacy of the system under curreat coaditions bazed on tha available
informatioa
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
r�`, �, INSPECTION REPORT
'�� G~
9kESH��'�
owner: /l I i J/� TT�I� Aflclress: Y��D �4 � - iCc( S�'.5'
Permit �'s: (JQ Dates:_� �� � � (.5` Contractors: 7—f� 1�l �L�'3�.
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is� an existing system [ ] neu construction)
SYSTEM CONFORMITY 1-3 :
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and uhich
is operating satistactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface uaters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system uhich may or may not meet atl the location, design, and construction standards of the current City
Codes and uhich is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic�has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been ident fied, this classification may be subject to revision.)
TANK CONDITION (5-10):
inspection indicates:
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be p�xnped out this year to help prevent future problems.
Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e.
9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next punpout. If tanks have not been pumped out uithin the last three years, they should be pun�ed
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accurnulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONOITION (11-14):
0 ield inspection indicates:
11 Drainfie[d is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed uithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.): --
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ���J
COMMENTS:
Date of Inspection eptic ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or cert�fy that an existing system witl continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prE�nises uith the system locptien and pumping records.
WHITE COPYllnspectors File YELLOW COPY/Homeowner
� o�
o :, o
=�=� ����=� CITY of ORONO
r� I��'�� ��` `� '�"
v�,, �; � ���� r� �!4 Municipal Offices
��'���,� i
�,� ,�,;,`�1��`�a��.�G Street Address: Mailing Address:
��k4,,
'q�tEggOg' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
� �
Owner: � _�Ir��P h Address: 4680 Bayside Rd.
Permit #'s: 7009 Dates: 6/2/95 Contractors: Patnode Bros.
(This is [�' an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 1
�, Code Svstem: Meets or exceeds current City standards in all respects relating to design,
�� construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Com�liant SXstem: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level [ �/j has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 5
�� Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or [�1 were not confirmed
to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subject to revision.)
�INFIELD CONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City 2nspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
PnTFNTTAT, FOR SYSTEM FAILURE• (sy�tem age and condition soils etc.) : low
COMMENTS:
�
� ��/ �
Date of Inspection Sep ic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 � FAX 473-0510