HomeMy WebLinkAboutSeptic info � O� O O C ITY of ORONO ,� � t4 Municipal Offices �� G~ Street Address: Mailin Address: g `9�t'EggOg'� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 CURTIS & ELIZABETH LEVANG 4010 BAYSIDE RD MAPLE PLAIN MN 55359 January 5, 2005 Dear Mr. Levang: This letter is regarding the large ice dam that is forining in your backyard. It appears that the ice is from sewage surfacin�from your septic system. Your drainfield or septic tanl<s may be fi•ozen and it is not cturently worlcing properly. This is an iinrninent health tlueat that must be repaired ASAP. Please contact a septic pumper or designer to lool< into the surfacing drainfield. Your septic system is classified as "non-compliant" and nnist be replaced by 12-31-2010 or if it starts to surface earlier. Before you stick in to much inoney in repairing yotu current drainfield you may think of replacing it since it must be done by 2010 anyway. Replacement camiot happen until this spring so we need to figure out a solution for this this winter. Please contact ine ASAP so we can figure this out and get it talcen care of. My number is 952-249-466. Sincerely, �± `-�,`���,��. ��~,� �'6-"�•��....._ .. � .���4�..' f / Lyle Oman Building Official Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us ;_� _ � � \. i��� A'� ;-� _ � ��,������� c��cY of o�o�va 1� �� r �,,, I� �I r� ,`� � � ;i , �, . Municipal Offices ��"v�,� ���, ��. �ti ` Street Address: Mailing Address: �9xEsx�4�� 2750 Kelley Parkway P.O. Box 66 � Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Cunent Owner of Address ��o I U �A�(5°�c�� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Ident' ed as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 � December 31,2010 Other � Septic Tank(s Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on �� i � - �? . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: �. Inspector: Date of Inspection � � ��� Telephone(952)249-4600 � Fas (9�2) 249-461h u�ww.�i.nrnn(l.mn.us /- / �.�, 0,�. O O ' ��� CITY of ORON4 +a ����r��_, � i �,,,�►�, ����';`,�1�:.� ';j� G,yti!� Municipal Offices 'Ii ,� �.I;fr�i,:1r ��9 � ;•,;;;��'g� Street Address: Mailing Address: k'EaB� 2750 Kelley �arkway �.0. Dox 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 . ——------------------------ -- - _ To Current Owner: Address: 40 S U I����rS:�� � City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM" An ISTS which meets all the location,desi;n and construction standards of the current Orono Municipai Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and consvuction standazds of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or /'� an imminent threat to public health or safery. ( � J"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within_a desienated 100-year flood plain,any ISTS which may �"� or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. TANK CONDITION(5-7): Tank inspection indicates: � Pumpout not needed at this time. � Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �d'��'c17 ). Make sure septic tanks are pumped throueh manhole and not throu�h white inspection pipes This allows for the proaer cleaning. Keep water softner and iron tilter discharge out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. INFIELD CONDITION 8-10 : t� 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly dischargin�untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: t��c�:�(�-:c�� �� S�t r.— �0-.4�.-�.�s- �1�� �..;15- �` ;cP\C,�c�� �Y �2-'��- 1.c�o . ,� ,: �� S:� �-.-�. �'�^��5 �`_-� s a� �, � 3 y�� �� �._`'� - 0 � �,� `�, �� Date of Inspection Matt Bolterman - Septic System Inspector tiote: In the event that this inspection report is used to satisfy the requirements for a mortga�e or other transfer of property,be advised that this report does not guarantee or certify that an existing system w�il l continue to function properly,but is merely an opinion of the adequacy of the system under current conditions bated on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us .�, o,�,. o : o =3�Y :i�� CITY of �RONO � � r� ,�3 a�j�` ►� � ,..�,��. f� '�;, ' ,� �, �`�,�����, �., �� Municipal Offices `� i i,•'1��i:�`���'�' G'� ���'','�;�;�°;;.�.g� Street Address: Mailing Address: �C'EggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 Owner:_ L V�-}�;5 Le�/q r�q Address:_ �f o I 0 QQ�s,J� �� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORIvIITY (1-3): 3 1 '�CODE SYSTEM" An ISTS which meets all the location,dzsigi and construction standards of the current Orono Municipal Code. 2 ��CONIPLIANT SYSTEM�� An ISTS which does not meet all the location,design and construction standards ofthe current Orono Municipal Code but does meet the three foot separation requiremzn�and which is not failing or an imminent threat to public health or safety. UNON-CONIPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a d�.signated 100-yeaz flood plain,any ISTS which may " or may not meet all the localion,design,or construction standards of the current Orono Municipal Coda and which is failing for any reason;and any ISTS with less than three fezt of unsaturated soil or sand bttween the distribution device and the limiting soil chazacteristics. TANK CONDITION(5-10): � Tank inspection indicates: - � Pumpout not nezded at this timz. � Tanl:must be pumped out this yzar (city code requires tanks 4o be pumped out every 3 years. Tank was last pumped ��►1-`17 �e 7 Solids accumulation in tanlcs is at a critical a critical lzvzl. Tanks should be pumped out as soon as possib(e. 8 Systam is dischazging to the surface. Tanks must be pumped out�vithin 48 hours to eliminate sutface discharge. 9 InspecRon risers missing-tanks could not be inspzctzd. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks have not bezn pumped out within the last three years,they should be pumped out now. 10 lnspzction pipa is located directly over tank ba$1e(does not give accurate measurement of solids accumulation). Iftanks have not bezn pumped out within the l�st three years,they should be pumped out now. DRAINFIELD CONDITION(11-14): ( � 1 1 Dra�eld is dry,no surfacing evident 12 Somz evidenca of surfacing,not critical yet � � ' . 13 Drainfield is saturatzd and visibly discharging untreated e�luent to tha surface. Cantact the City Inspector unmediately.Repain must be complettd u•ithirt 90 days. 1=� Draintizld t�Zent and condition unknown. COMNfENTS: Sys�^^ rn�Sr 6� r� I��e� Ia- 31 -io, poes �o�- c.o��-ar� �c� 3 -�oofi Sc�C�a�a,� �MP �-a�k5 S-a9-o� �a� �— Date of Inspection Seplic System Inspector Note: In the event that this inspection tepoR is used to satisfy the requuements for a moetgage or other transfer of propecty,be advised that this repoR does not guazantee or ceRify that an e;usting system will continue to function properly,but is merely an opinion of the adequacy of the system undzr cu¢ent conditions based on the available infortnation. CITY OF ORONO � O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT r$`,, � INSPECTION REPORT 'C�� G~ � 9kESH�4' Owner: �l 5 t��UGfI?GI Address: ���� �i¢�/�5'!(�Q. /Ce{ ��J.�S� ) Permit #'s: `/3J� /� Dates:�'" ' �� ZD 6 Contractors:{t• JDd1615o°91, E/• �J�"i2�� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is�an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface Waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic� has or [ 7 has not been identified at this time. If the limiting soil characteristic has not been identtfied, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be puriped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. System is discharging to the surface. 7anks must be pumped out uithin 48 hours to eliminate surface dischar�e. 9 ]nspection risers missing-tanks could not be inspected. [nspection risers (4" dia, pipe) must be installed in each tank at next pumpout. If tanks have not been punped out Within the last three years, they should be pumped out now. 10 inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): n ield inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknoan. LIMITING SITE FACTORS (slope,setbacks,etc.): --. POTENTIAL FOR SYSTEM FAILURE (depends on soils,uater table,etc.): ���jL( h'L COMMENTS: ° .5 f� IS dYtLG'YZvLe�i1 �r�i O-� �l-rcG� c7t Q,J 1y..t2/ c�"f S-E� c�;�? �i0�� ' v " 1J G�c- �� 4 �� l - -ZG-�7, r Date of Insp ction eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system locetion and pumping records. WHITE COPYllnspectors File YELLOW COPY/Homeowner � o� o :�, o � �����=- CITY of ORONO �a �F����� � r�,� ), �:y'�� ��� �Fr Municipal Offices g � `�'�` l�'�� G 9'�`�,':��i�o�g.� Street Address: Mailin Address: �fEggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: l �l'11'S F�✓artiq Address: 4010 Bayside Rd. Permit #'s: 5433, 1108 Dates: 11/30/78, 7/20/61 Contractors: Arnie Johnson, Bob Benson (This is [x] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code $ystem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Com�liant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. �3 Non-Com�liant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [x] has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks �J have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [�] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) N N 11-14 : 11 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. PnTFNTTAL FOR SYSTEM FAILURE• (system age and condition soils etc.) : medium COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2007. 7��� � � Date of Inspection Sep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON–SITE SEWAGE TREATMENT � � INSPECTION REPORT ti ��9kESH��'�G Owner: Address: �� [Ys/1K;1.1f: l�O(� Permit #'s: t+- $ �/ Dates: – Q' Contractors: /�xp ,�n�V�/tlrnr�P ..l�v�i�, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is �L an existing system [ 7 new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. � "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants tnto ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or � has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. (bl Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. –7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr�nfield inspection indicates: n v Drainfield is dry, no surfacing evident. �r2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ����� COMMENTS: �� �— Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prEmises uith the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT . POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER � � ADDRESS `7���� ���'�r�� /�` PERMIT NO.'S. DATES �pv�—��' CONTRACTORS P � �� P I� 't�—0�0—� ' �'zsca-� City Ordinance No. 210 requires that each on-site sewage treat�ent system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is ❑ an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,constructio�,and location.Appears to be operating properly. riv'2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, ���� located, and constructed generally in accordance with previous codes. System a ars to be functionin ro rl ppe g p pe y; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is tailing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.► If tanks � Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �-Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to elimi�ate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia, pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now, ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table ❑ Low �-Fair ❑ Lot size �-Medium O Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: r� _,��-9J �, , �" � d ',�_-- Date of Inspection S ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does �ot guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On th.e North Shore o f Lake Mi�znetor2ka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER �UieTIS LEV/-�"IV�' ADDRESS `C��� ,b��YSl�4� /�l' 5-t�3 3 //- 3 e, _ 7� t`�R/1�!C �/U HNsai✓ PERMIT NO.'S. �/-�^�,-�— DATES ��-- �-� CONTRACTORS ����0� City Ordinance No, 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above ress has been inspected and appears to fall into the category checked below. (This is an existing system ❑ new construction) ` � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating � properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future probiems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is tailing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ��(-E �—�—� Solids accumulation in tanks is at a critical level, Tanks Drainfield inspection indicates: ���KS should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped oui within � immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. Drainfield extent and condition unknown. SITE CHARACTERISTICS: PREJ�.(l�'1�D �►'z�� ��y Limiting Site Factors Potential for System Failure Site Capabilities tor ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) � Adequate ❑ High water table ❑ Low ❑ Fair ❑ Lot size �, Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible S(�Ec surface discharge. JNF TrC,.f- COMMENTS: R!S"ERS /�?UST L�� /N�S'%/3-LCE� DN T�`�ICS � � 2 • /H/V�K � 2 s��c,� �o v�r� � �,�t/� o ni G 2 0�,�-o _ �'�NK �` / F�P�•+�'�N'� < E'r.s c✓ftT�2 ¢ ��82� u;✓ -- ADQi S'r�4cir�s wjcc ��cv o7- rPo c s ��,�z� �.,�� /G � r� �S Date of Inspection Septic System Inspector PERr�?�g-�tnrr�� vn/-��K THE�� L_ec H�c �S ,. Note: In the event that this in pection report is used to sat�s y the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY /Homeowner � On the North Shore of Lake�Ylinnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 � 1335 S. Brown Rd. � _ � � Crystal Bay, MN 55323 473-7357 OWNER �ED �L��S�N ADDRESS `�`� �.�4YJ/l�F �C�/{-jj PHONE PERMIT NO'S. ��° %1�0 /S�/�.3 DATES �'zu ���/-3D•�78 City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ❑ � Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. �� Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. ❑ � Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ � Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: � Septic tanks must be pumped within 48 hours. NST�L � CO��� OF Drainfield must be repaired or replaced within 90 days. ,� � � �� �,�� •r�.�17� pF'�NlN� ❑ !J� �,,,.� �� �.t � ( . f3i,r,cr< �'n�o I ection riser (4"diam. pipe) must be installed in each tank. p �n�c � � � Tank inspection indicates maintenance pumpout is needed as soon as �sible. City ordinance requires that tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for `�Slope (depends on soil types,water Future Expansion ��Soil table,and system condition) �Adequate ❑High water table ❑ Low � Fair ❑Lot size �Medium ❑ Poor ❑Lake,wetland,or stream ❑ High ❑ Inadequate �Drainage �System is causing visible surface discharge. COMMENTS: NC��� : .x /l/07�� -�1�4--Tr4 G�Es�/CL� c�/2 l•�€�/ICL�S /�/�$� ��� .1��/U//UG QY�� 7tft' D�24/NF/Ez� A��A '- -�'�l/.� �'�OvrL'1 �� �iZ7f'PF`� uL L .AN Gl/c�E , , , f� — � --� � � Date of Inspection Septic System ector This report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY/Homeowner