Lighting Plan 10-24-2001 - Medina Electric
MEDINA .` '`= Meil ELECTRIC, INC. • LETTER OF TRANSMITTAL 2724 Fernbrook Lane North PYMOUTH, MINNESOTA 55447 DATE JOB NO. (763) 478-6828 FAX (763) 478-6055 10/24/2001 ATTENTION MOOR: 6111C/WAI TO RE City of Orono ORONO APARTMENTS 2750 Kelley Parkway Orono, Minnesota 55356 WE ARE SENDING YOU XX Attached ❑ Under separate cover via the following items: Shop drawings ❑ Prints LI Plans Samples LI Specifications Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION 2 sets PHOTOMETRIC SITE LIGHTING LAYOUT THESE ARE TRANSMITTED as checked below: X For approval ❑ Approved as submitted ❑ Resubmit copies for approval X(For your use ❑ Approved as noted ❑ Submit copies for distribution XXX As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ ❑ FOR BIDS DUE ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO Mr. Mike Benedict - Frana & Sons, INc. SIGNED: Wally Cisewski PRODUCT 240T If enclosures are not as noted,kindly notify us at once. � I STEEL SQUARE POLES STEEL Steel Square Poles from LSI Lighting Systems offer durable aesthetics to enhance your specified lighting design. For a look that lasts, specify LSI poles. SQUARE SPECIFICATIONS POLES POLE SHAFT BASE GROUND LUG Pole shaft is electro-welded Pole base is ASTM-A36 hot-rolled Ground lug is standard. ASTM-A500 Grade C steel tubing steel plate with a minimum yield DUPLEX RECEPTACLE with a minimum yield strength strength of 36,000 psi.Two-piece SON- SQBO- of 50,000 psi.On Tenon Mount square base cover is optional. Weatherproof duplex receptacle 2.3/8"0.0. Bolt-On is optional. x 4-3/4" Mount, steel poles,tenon is 2-3/8"O.D. Tenon 2-Bolt high-strength pipe.Tenon is 4- ANCHOR BOLTS GROUND FAULT Pattern 3/4"in length.Straight poles are Poles are furnished with anchor CIRCUIT INTERRUPTER 4",5",and 6"square. bolts featuring zinc-plated double nuts and washers.Galvanized Ground fault circuit interrupter HAND-HOLE anchor bolts are optional.Anchor is optional. Standard hand-hole location is bolts conform to ASTM A36 with FINISHES 12"above pole base.Hand hole a minimum yield strength of Each pole is finished with DuraGrip', size is 2"x 4". Poles 22'and 36,000 psi. LSI Lighting Systems'revolutionary SQP- above have a 3"x 6"reinforced superior baked-on polyester-powder SqPole Topre hand hole. finishingprocess,togivethe ole an Pole P ® exceptionally attractive appearance. STEEL SQUARE POLES The process electrostatically applies 5" and 6" steel square poles) and thermally fuses a polyester POLE SELECTION CHART (4", powder to the pole.This unique 14'39' sql- Height EPA' Outside Material Bolt protection process provides an No 70 MPH 80 MPH 90 MPH 100 MPH Dimensions Circle Mounting14' 23.3 16.7 12.2 9.0 4" 511G B extremely smooth and uniform Holes 16' 18.6 13.1 9.3 6.5 a S11G B finish which withstands extreme 16' 34.6 25.0 18.5 I 18' 14.4 9.7 6.5 13.8 5' S11G c weather changes without cracking 4.2 4' S11G B or peeling.DuraGrip finish features 18' 27.9 19.7 14.1 10.1 5' S11G c a two-year limited warranty. 20' 11.0 7.0 4.2 2.2 4" S11G B Standard finish colors available for 20' 18.7 12.8 8.8 5.9 4' SO7G B are bronze,black,platinum 20' 22.5 15.4 10.5 7.0 5' 511G c poles SF- 20' 35.5 25.4 18.4 13.4 5" SO7G D plus,buff,white,and green. Single 22' 10.4 6.3 3.4 1.4 4' S11G B Optional DuraGrip' Plus features Flood Pole 22' 18.7 12.6 8.4 5.4 4' SO7G B Preparation 22' 20.8 13.8 8.9 5.5 5• S11G c added protection with a 3.0 to 5.0 22' 34.0 23.9 17.0 12.0 5' SO7G D mil thickness of polyester-powder 7.7 4.0 1.s - 4 sjjG B finish plus an inner coating.This 24 „fsT" . SO7G B specially developed inner coating 24' is a thermal plastic hydrocarbon 24' 22.5 14.9 9.7 5.9 5• S11H' D resin applied 28.6 19.6 13.4 8.9 5' SO7G o t0 the inside of the 24' 46.2 32.6 23.2 16.6 6' SO7G J pole to seal and protect against 26' 5.3 2.1 - - 4' 511G B atmospheric and corrosive matter. 26' 12.0 7.2 3.9 1.5 4• 5070 B DuraGrip Plus finish features a 26' 13.2 7.6 3.8 1.0 5• S11G c five-year limited warranty. 26' 24.0 15.8 10.3 6.3 5• SO7G D 26' 39.6 27.3 18.9 12.9 6' SO7G J 30' 16.3 9.6 5.0 1.7 5' SO7G D 30' 28.8 18.6 11.6 6.6 6" SO7G J 35' 18.3 10.0 4.3 6' SO7G J 39' 11.5 4.3 - - 6' SO7G J Hand-hole Refer to EPA data sheet for complete EPA information '-H•denotes high yield steel(70,000 psi). 12" Optional Standard Base Cover Follow these steps to determine the luminaire/pole combination for your application. • Select luminaire from Luminaire • Refer to Luminaire EPA Chart ' Select MPH to match the wind speed in Projection (4)w. Ordering Information. to determine EPA value. the application area. a 1 '` Anchor • Select bracket configuration. • Select Height of pole. • Confirm the pole EPA that is equal to or Bolts exceeds the luminaire/bracket EPA as was previously determined. Foundation By Other k • i Lighting Systems' ©LSI Industries Inc. REV 2/01 10000 Alliance Road • Cincinnati,Ohio 45242♦ (513)793-3200 FAX(513)984-1335♦ www.lsi-industries.com STEEL SQUARE POLES ki Lighting Systems'" CATALOG# TYPE BOLT CIRCLE 4"square 5"square 5"square 6"square 00-118"sq.I r10-1/8"sq.1 -10-1/8"sq. r---12"sq.— <D ' 01 11"Bolt Circle ' 11"Bolt Circle 11"Bolt Circle 12"Bolt Circle B C D J Slotted Slotted Slotted Bolt Circle 8'to 11" 9'toil' 9"to 11' 12" Anchor Bolt Size 3/4"x 30" 3/4"x 30" 1"x 36" 1"x 36" Anchor Bolt Projection 3-1/4" 3-1/4" 4" 4' Base Plate Opening for Wireway Entry 3-5/8" 4-3/4" 4-5/8" 5-5/8" Base Plate Dimensions 10-1/8'sq.x 3/4"thk. 10-1/8"sq.x 3/4'thk. 10-1/8'sq.x 1"thk. 12'sq.x 1 1/8"thk. Note:Base plate illustrations may change without notice.Do not use for setting anchor bolts.Consult factory for the base plate templates. 4— ORDERING ORDERING INFORMATION Select appropriate choice from each column to formulate order code.Refer to example below. Pole Material Height Mounting Pole Finish Options Series Configuration 2 ' ••.ttem S - 11 Ga. 14' BRZ- Bronze GA- Galvanized Anchor Bolts ,SC/re 7 - a.Steel 16' 80 Do BLK- Black SF- Single Flood' a:t Si . eel 18' D90'- Double PLP- Platinum Plus DF• Double Flood' 6SQB0 20' DN90' - Double BUF- Buff DGP- DuraGrip' Plus Consult pole selection 22' T90' - Triple WHT- White LAB- Less Anchor Bolts chart on opposite page. TN120' -Triple GRN• Green NO- No Options 6' Q90' - Quad 30' QN90'-Quad Square Pole for 39 PT- Pole Top Mount AM tS 4' Pole Top Mount 4SQP 5SQP 6SQP Square Pole for N- Tenon Mount Tenon Mount (Standard tenon 4SQN size is 2"pipe) SSQN 6SQN Consult pole selection Standard SF and DF pole preparations chart on opposite page. are located 3/4 of the height of the pole Square Pole from the base,unless otherwise specified. (No mounting holes No pole top caps) 4SQI 1 5SQI I— I I L____— 1 I EXAMPLE OFA TYPICAL ORDER 5SQB0 SO7G 24 D180 PLP SF DGP ACCESSORY ORDERING INFORMATION DRILLING LOCATIONS (Accessories are field installed) _ Sides Description Order Number Side A B C D 4'Square ABS .draw 164193' > i Hand-hole X I Single X 5BC- 5'Square ABS Base Cover 164194" \\ D180' X X 6BC-6'Square ABS Base Cover 164195' 17i \ D90' X X ER2-Weatherproof Duplex Receptacle 122566PLT I T90' X X X GFI•Ground Fault Circuit Interrupter 122567PLT 50 I — —Side ill Sg T120" X MHP- Mounting Hole Plugs(3 plugs standard) 132336 j� iA Q90' X X X X 1"NTCVR-Nut Cover(set) 142805CLR** Ill Single FB0 X � "Specify finish "Compatible with 3/4" and 1" anchor bolts I Double FBo X X side 'Other two locations wit be 120'to the left and right 01 Side A. •A" (Hand-hole Side) Note:Consult factory for custom variations. Standard SF and DF pole preparations are located 3/4 of the height of the pole from the base,unless otherwise specified. All LSI Lighting Systems'poles are guaranteed to meet the EPA requirements listed.LSI Lighting Systems is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located.Caution:This guarantee does not apply if the pole/bracket/ fixture combination is used to support any other items such as flags,pennants,or signs,which would add stress to the pole.LSI Lighting Systems cannot accept responsibility for harm or damage caused in these situations.Note:Pole calculations include a 1.3 gust factor over steady wind velocity.Example:poles designed to withstand 80 MPH steady wind will withstand gusts to 104 MPH.EPAs are for locations 100 miles away from hurricane ocean lines.Note:Hurricane ocean lines are the Atlantic and Gulf of Mexico coastal areas. J ©LSI Industries Inc. REV 2/01 1°111.° LIGHTING SYSTEMS . . . ___ __________:_:____ ...0 • .14 41- (r •r .0 • . , "' ,,.I •t Zli t" , -- 1 .., -i •: „ r. 1 i vi 7 1 T1, ., I, i ) .• ,111,1.. ,1 .''., ., :-.. .'' — . 11 l.:1.• .'a i '•1' ith4.4. i - ' .- „- -----L--= , - ---------______ • ',•;"=,-.-' -,- ===_MIIVINNIOr'• .--•''''..:1;,g;.:‘,., ,• ... . ,-,g;,!: ,‘„i.l.:',4",:•.;,-,,,,,,, - . . ”• . . -,,,,-..„:::,40". :V tbr'?!'t',--,0,"vy,'-'w' ' ---- • - •,-,1-_-_,A,.F.,44.44;,-.:1-11..$- -"?:;?------4.,: -, ... • .,-..--—,; -:. '.•,-:,,,,w-,4,,-?1,444,1,--A=4,-?.„-,-,- - ,-p----.--,..,nie,','..--.-,,,,..."„Y,'LiC-''''' .'.,. : . '-',-N,..--, '',-,,!:4-'•".-----,.!• .,,,,, - ,,,„IF, - . •,- .-:, :,''i.'-',. ';,' Vtlr,7**"4,'-''' ,r.,.,.. .......,..,,,,,........,--- THE CITATION N SERIES ....._ . . ... _ _ . ,„... - Excellent Lighting Contro . ;,.• • • 1. .... . Exceptional Value - ----- VV- - -- ,.. .:.,-- ... .. ..... ••• ... .. . . :,:,;•-,-.7-= .. . .. ,, • ----,,,,, .••,,,•• • , . •.....,........., '-t*.Y.IfelMillrialla '' '4*VelifiNlilk, ::ZIANNINIININIMIk, ..' THE CITATION SERIES — A WIDE VARIETY OF OPTICAL CHOICES FOR MAXIMUM OPERATIONAL VALUE One of the best just got better. Featuring the ultimate in high performance and efficient construction,the Citation Series has , been improved to offer a wider variety of enhanced optical choices.Depending on your requirements, you can choose from three sizes,in addition to CITATION LARGE wattages ranging from 100 to 1000. HORIZONTAL BURN For new construction or upgrades to existing sites,the Citation Series offers you an extensive - ►� — < ��� selection of energy-saving features designed to A help improve the safety,security and overall image of any outdoor lighting area. CITATION MEDIUM HORIZONTAL BURN INTRODUCING THE CITATION II LSI Lighting Systems has expanded the Citation family to include the Citation II,featuring a 400-Watt reduced envelope,Vertical or Horizontal li fy, Burn lamp option in the small Citation housing.With - . the Citation II,you can enjoy one of the outdoor lighting industry's finest operational values. CITATION II -- VERTICAL BURN The Citation II is loaded with cost-saving features, T including flat or sag glass lenses,Pulse-Start — - Metal Halide lamps,optional toolless entry/ground re-tamping(ground re-lamping on Citation ll . CITATION II vertical burn only),plus more. HORIZONTAL BURN S: .,, ,,,r4, ', HIGH—PERFORMANCE VERTICAL BURN OR HORIZONTAL BURN WI 311.''.' " 'w'l : .:'‘.4-‘.';''7'4 t :::,,''•= 1.1 wi :,7,:'.. '':'.', , -7- .„...______ L._ . ... [,, , - , ,,,,, ,, .„... . , , ,, ,_ . , : . ____ - Vertical Burn Horizontal Burn Utilizing a sag lens,Vertical Burn fixtures When your lighting requirements include control light output and distribute light more sharp cut-off luminaires with a high degree evenly over a larger area. of light control,specify Horizontal Burn. High-performance reflectors surround the Utilizing a flat lens,horizontal lamp orientation vertically oriented lamp to deliver brilliant and high-performance reflectors,Horizontal light and provide maximum lighting Burn fixtures allow you to place more direct distribution and uniformity.This creates emphasis on ground elements without better"see-ability"and efficiency using sacrificing uniformity. fewer fixtures,thus lowering your total • Powerful,sharp cut-off illumination— I l I t! _-- cost of ownership. meets IES Full Cut Off Classification ' —-. r . p • Greater lighting effectiveness and efficiency ■ Excellent for areas with strict with fewer fixtures zoning requirements 1 - 1 , ■ Lower energy costs w 3 ■ Lower installation costs ,i`......11,40,. :_ - — 4- `, ■ Lower total cost of ownership HOUSING BALLAST One-piece aluminum housing High-power factor type ballast is available in small,medium r '' is designed for-20°F operation. and large sizes.Welded and ,'.� Ballast is mounted to the housing finished corners provide a clean, reinforcing plate. sharp appearance, increased 4 '—'�;'"j housing strength and BRACKETS weather-tight construction. Aluminum bolt-on bracket is shipped standard(2 1/2"x 6"x 6" LENS/GASKET on small models,21/2"x 6"x 8" Clear,flat tempered glass lens SOCKETS on medium models,21/2"x 6"x 12" or sag tempered glass lens is 4 Porcelain,mogul-base sockets feature on large models).Optional 6" sealed to the housing with an spring-reinforced contacts for long life. bracket is available for single EDPM gasket to prevent entry and D180°configurations. of moisture and insects. EASY ACCESS Standard doors feature two captive, INTERNAL FITTERS LIGHT SOURCES stainless steel door fasteners,which -, Upgrading to the Citation Series Designed to operate with either provide secure closure and easy is easy and cost-efficient with a High Pressure Sodium;Super access.Optional,on Citation II fixtures, one of LSI's patented Metal Halide Reduced Envelope; is a new spring-loaded quarter-turn I Internal Fitters(U.S.Patent "" No.5,599,094).For existing Metal Halide;or Metal Halide lamp entry"by hand,or"ground re-tamping" �. 4"or 5"square poles,insert with mogul-base sockets.A clear FIXTURE SHOWN: with a special re-lamping tool.Ground an Internal Fitter in the pole, lamp is supplied as standard. cr2v crrarroN a re-lamping is only available on vertical and turn to tighten. burn Citation II fixtures. REFLECTOR OPTIONS The Citation Series offers a wide variety of reflector choices to meet your needs,including these high-performance options: 1 CITATION II (CT2H) CITATION II (CT2V) CITATION MEDIUM HORIZONTAL LAMP/FLAT LENS OPTIONS VERTICAL LAMP/SAG LENS OPTIONS (CTM) TYPE 3 TYPE 5 FORWARD THROW TYPE 5 TYPE 5 Optional Ground Re-Lamping A ground re-lamping option is available for vertical burn Citation II fixtures with 1l1_ ier lower pole heights.A special ground re-lamping tool opens and closes the unit, in addition to removing and replacing the lamp,making re-lamping remarkably easy. • No bucket truck or ladders necessary • No need for the added expense of hiring an outside contractor • Maximum tool length of 15' Pulse-Start Metal Halide Lamps With Pulse-Start Metal Halide lamps(available on Citation II vertical burn fixtures only),you can enjoy the white light of Metal Halide,along with the energy efficiency and lumen maintenance of High-Pressure Sodium. PULSE-START CASE STUDY 400 CWA 320 Super CWA Consider the benefits: COMPARE (Standard M.H.) (Pulse-Start) • Longer lamp life(up to 30,000 hours) Feature Standard 1[ ^f�'7� H.P.S. System Watts 458 Watts 365 Watts M.H. rT�' '� Per Fixture • More lumens per watt Color white Whiter Yellow Mean Lumens 28,800 26,400 • Better lumen maintenance for more light output over time Efficacy(L/VV) 60-85 90-110 100-125 • Improved color stability and less color shift Lumen Maint. 65% 80-85% 90% Fixtures 20 20 Power Cost • Faster warm-up Lamps 175-1000 35-750 35-1000 Per Fixt.Per Yr. $146.00 $116.00 Lamp Life(kHrs) 6-16 15-30 24+ @ 81t(4000 Hrs) Total Savings=$30 X 20=$600 Per Year,Forever! CITATION ORDERING INFORMATION (Select appropriate choice from each column to formulate order code. Refer to example below.) Luminaire Lamp Light Line Luminaire Prefix Distribution Watta-e Source Lens Volta:e' Finish O°tions CT2H-Small A-Asymmetrical 100 HPS- High Pressure Sodium F- Clear Flat 480 V BRZ-Bronze 6BK- 6"Bracket (Horizontal lamp) 3-Type III 150 100,150,250,400 Watt Tempered MT-Multi-Tap' BLK-Black (CTL and CTM►' FT-Forward Throw 175 SMH- Super Metal Halide Glass TT-Tri-Tap' PLP-Platinum Plus PCR- Photoelectric Control /'" 5-Type V 250 175,250 Watt BUF-Buff Receptacle 400 MH- Metal Halide WHT-White LL- Less Lamp 175,250 Watt GRN-Green C- Coated Lamp SMHR-Super Metal Halide NO- No Options Reduced Envelope 400 Watt TE/GR-Toolless Entry/ MHR- Metal Halide Ground Re-Lamp' Reduced Envelope 400 Watt CT2V-Small FP-Forward Perimeter 150 PSMV-Pulse-Start Metal Halide CT-Clear Y Y�r)vi5t- (lot/66 (Vertical lamp) 5-Type V 175,250,320 Watt Tempered 175 SMVR-Super Metal Halide Sag Glass Reduced Envelope 400 Watt 250 MH- Metal Halide 175,250 Watt 320 HPS- High Pressure Sodium 150 Watt 400 MHR- Metal Halide Reduced Envelope 400 Watt CTM-Medium A-Asymmetrical 250 HPS High Pressure Sodium F Clear (Horizontal la -3. 250,400 Watt Tempered FT-7M—ward Throw SMH uper Metal Ha I Glass 5-Type V 250,400 Wat H— le 250,400 Watt CTL-Large A-Asymmetrical 1000 HPS- High Pressure Sodium • (Horizontal lamp) 3-Type Ill 1000 Watt FT-Forward Throw' MH- Metal Halide 1000 Watt I Example of Typical Order CT2H 3 400 SMHR F MT BRZ NO '1 1)CTL-FT—Forward Throw reflectors are field-rotatable. 51 Tri-Tap is shipped standard for C-UL applications.Tri-Tap consists of 120V,277V,and 347V.Tri-Tap is C UL US 2)For international voltages,consult factory. pre-wired for 347V.Alternate voltages will require field re-wiring. LISTED 3)MT—Multi-Tap is shipped standard unless otherwise specified.Multi-Tap consists of 120V,208V,240V 6)Ground re-lamp option available on CT2V only.Toolless entry option available on Listed far et ocations. and 27N Multi-Tap is prewired for 277V.Alternate voltages will require field re-wiring. CT2V and CT2H only. 4)A 6"bracket can only be ordered with single and D180'configurations on CTL and CTM. Note:PCR factory installed and pre-wired for 277V.Alternate voltages will require field re-wiring. LUMINAIRE EPA CHART *— 1111-e41 �� 44 + , Includes Bracket. Single D90° D180° T90° TN120° Q90° Parallel Small Citation(CT2V)6"Bracket 1.5 2.4 3.0 3.9 3.9 4.7 — Small Citation(CT2H)6"Bracket 1.4 2.2 2.8 3.6 3.6 4.4 — Medium Citation(CTM)8"Bracket 2.2 3.9 4.0 6.1 6.2 7.8 — Large Citation II(CTL)12"Bracket 3.2 5.1 6.4 8.3 8.5 10.2 5.1 ACCESSORY ORDERING INFORMATION (Accessories are field installed.) Description Order Number Description Order Number PC120V-Photocell 122514 CT2V HSS-House Side Shield 122519" PC208V-Photocell 122515 CT2H HSS-House Side Shield 122519" PC240V-Photocell 122516 CTM HSS-House Side Shield 122520" PC277V-Photocell 122517 CTL HSS-House Side Shield 122521" PC480V-Photocell 122518 CT2H PLS-Polycarbonate Shield 122522 FK120V-Single Fusing FK120V CTM PLS-Polycarbonate Shield 122523 FK277V-Single Fusing FK277V CTL PLS-Polycarbonate Shield 122524 DFK208,240V-Double Fusing DFK208,240V APP-Round Pole Plate 6908901" DFK480V-Double Fusing DFK480V BKS-BO-WM-'-CLR Wall-Mount Plate 123111 CLR FK347V-Single Fusing FK347V Ground Lamp Changer C/F "Black only. LUMINAIRE FINISHES DIMENSIONS Polyester-powder coat finish is guaranteed not to crack,peel or oxidize for five years. D-, -A- ...111.111Ij II BUFF GREEN WHITE BLACK SAG LENS BRACKET- ' J 2-BOLT PATTERN Al „I.10POWDER A BCD E Note: six-inch bdlwt abramall COATED — is shipped standard with small TOUGH' CT2V(Small) 20-1/8" 8" 14-5/8" 6" 11-1/4" Citation.An eight-inch bolt-on BRONZE PLATINUMbracket is shipped standard CT2H(Small) 20-1/8" 8" 14-5/8" 6" with a medium Citation.A iJ PLUS CTM(Medium) 25" 8" 18-3/8" 8" — twelve-inch bolt-on bracket is �I11dUSt/I@SrM CTL(Large) 29" 10" 21" 12" — Citatiiion,sunlessrothervsh a e large LSI INDUSTRIES INC. 10000 Alliance Road • Cincinnati,Ohio 45242• (513)793-3200 FAX(513)984-1335♦ www.lsi-industries.com ©2000,LSI INDUSTRIES INC. 11/00-10M 1 - '.' ••• . ... ... I IIIII, 11111•11‘1111111 IIIIMIIIIIMI .., E-1 ill C4 Z ,• _ _ _ i24 Z 1 3 i ... ., C4 1:C1 IIIIIIIIIIII ., , - , %12 1.21 • 1.0 (,.9 0 <52 CP 'z' 3111111111F: 0 _ ] Wayzata (------ _ 9 Luminaire Schedule Project: All Projects Symbol Qty Label Arrangement Lumens LLP Description El 5 AA SINGLE 40000 0.750 LSI #CTM-3-400-SMH-F WOOD o�Q 1.0 •1.0 9.3 9.1 9.3 0.8 •1.0 0 5 •2.7 0.8 0.8 1. 1 7_ 5 i p fin- F 9 t 9 9 7 4 5 .41 •.• .3.. 77, b, 41.8 1. 0 5 .8 2 9 •1..9 9.• 2., 9. ., TYPICAL 10-12 FOP LIGHT POLES • .- •1.4 2. 5 "' p •1.9 •1.5 4 >.3 9.t 9.5 9.6 9.6 6.• 2.0 •1.• 9. 9.1 9.1 9.2 9.4 2.1 2.4 0.9 0.6 0.6 0 Blvd. (U. S . Hwy. No . 12) Numeric Summary Scale 1" - 70' Project: All Projects Label CalcType Units Avg Max Min Avg/Min Max/Min Orono Site Illuminance Fc 2.14 6.9 0.4 5.35 17.25