Loading...
HomeMy WebLinkAbout10-11-2021 Septic Compliance 24910 Territorial Road, Rogers, Minnesota 55374 • 763-428-4489 info@endeseptic.com • www.endeseptic.com ______________________________________________________________________________ Project: 1700 Shoreline Dr Wayzata, MN 55391- Caretaker Home A septic compliance inspection was completed, and the system is Compliant according to the MPCA codes for Chapter 7080 and local codes for the City of Orono in Hennepin County. The system the following attributes: Date Home Built: 1970’s? Bedrooms: 3 Date Septic Built: 1970’s Septic Tanks: 1000-gallon septic tanks, inlet and outlet baffles in place, manhole covers to grade. Pump Tank: n/a Soil Treatment: Gravity fed trench system. 3 trenches each about 40 feet in length. Issues Found: n/a Ende Septic Service, LLC, has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. State. Sec. 155.55 (2010). The compliance inspection covers only the criteria required by Minn. Stat. Sec. 155.55, Subd. 5a (2010 and Minn. R. 7080.1500 (2011). A Compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Ende Septic Service, LLC, disclaims any use of the compliance inspection beyond determining SSTS compliance pursuant to Minn. Stat. Sec. 155.55 (2010). https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 1 of 4 Compliance inspection report form Existing Subsurface Sewage Treatment System (SSTS) Doc Type: Compliance and Enforcement Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at https://www.pca.state.mn.us/sites/default/files/wq-wwists4-31a.pdf. Property information Local tracking number: Parcel ID# or Sec/Twp/Range: 1011723140022 Reason for Inspection Property Transfer Local regulatory authority info: City of Orono Property address: 1700 Shoreline Drive Orono, MN Owner/representative: H and H Homes-Randy Owner’s phone: 612-619-7227 Brief system description: 1000 gallon septic tank to a gravity fed trench system. System status System status on date (mm/dd/yyyy): 10/11/2021 Compliant – Certificate of compliance* Noncompliant – Notice of noncompliance (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A.04 subdivision 8. Reason(s) for noncompliance (check all applicable) Impact on public health (Compliance component #1) – Imminent threat to public health and safety Tank integrity (Compliance component #2) – Failing to protect groundwater Other Compliance Conditions (Compliance component #3) – Imminent threat to public health and safety Other Compliance Conditions (Compliance component #3) – Failing to protect groundwater System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) – Failing to protect groundwater Soil separation (Compliance component #5) – Failing to protect groundwater Operating permit/monitoring plan requirements (Compliance component #4) – Noncompliant - local ordinance applies Comments or recommendations This Inspection is for the caretakers home on the east side. Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: Ende Septic Service Certification number: C9206 Inspector signature: License number: L2654 (This document has been electronically signed) Phone: 763-428-4489 Necessary or locally required supporting documentation (must be attached) Soil observation logs System/As-Built Locally required forms Tank Integrity Assessment Operating Permit Other information (list): https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 2 of 4 Property Address: 1700 Shoreline Drive Orono, MN Business Name: Ende Septic Service Date: 10/11/2021 1. Impact on public health – Compliance component #1 of 5 Compliance criteria: Attached supporting documentation: System discharges sewage to the ground surface Yes* No Other: Not applicable System discharges sewage to drain tile or surface waters. Yes* No System causes sewage backup into dwelling or establishment. Yes* No Any “yes” answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: 2. Tank integrity – Compliance component #2 of 5 Compliance criteria: Attached supporting documentation: System consists of a seepage pit, cesspool, drywell, leaching pit, or other pit? Yes* No Empty tank(s) viewed by inspector Name of maintenance business: Ende Septic Service Sewage tank(s) leak below their designed operating depth? Yes* No License number of maintenance business: L2654 Date of maintenance: 10/11/2021 Existing tank integrity assessment (Attach) If yes, which sewage tank(s) leaks: Date of maintenance (mm/dd/yyyy): (must be within three years) Any “yes” answer above indicates the system is failing to protect groundwater. (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 B (1)) Tank is Noncompliant (pumping not necessary – explain below) Other: Describe verification methods and results: 1000 gallon septic tanks pumped through the manhole covers. Riser installed to bring the manhole cover to grade. https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 3 of 4 Property Address: 1700 Shoreline Drive Orono, MN Business Name: Ende Septic Service Date: 10/11/2021 3. Other compliance conditions – Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? Yes* No Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? Yes* No Unknown *Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non-protective of ground water for other conditions as determined by inspector? Yes* No 3d. System not abandoned in accordance with Minn. R. 7080.2500? Yes* No *Yes to 3c or 3d - System is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: Not applicable 4. Operating permit and nitrogen BMP* – Compliance component #4 of 5 Not applicable Is the system operated under an Operating Permit? Yes No If “yes”, A below is required Is the system required to employ a Nitrogen BMP specified in the system design? Yes No If “yes”, B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is “no”, this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? Yes No b. Is the required nitrogen BMP in place and properly functioning? Yes No Any “no” answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: Operating permit (Attach) https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 4 of 4 Property Address: 1700 Shoreline Drive Orono, MN Business Name: Ende Septic Service Date: 10/11/2021 5. Soil separation – Compliance component #5 of 5 Date of installation 90's Unknown (mm/dd/yyyy) Shoreland/Wellhead protection/Food beverage lodging? Yes No Attached supporting documentation: Soil observation logs completed for the report Two previous verifications of required vertical separation Not applicable (No soil treatment area) Compliance criteria (select one): 5a. For systems built prior to April 1, 1996, and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock. Yes No* 5b. Non-performance systems built April 1, 1996, or later or for non- performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* Yes No* Indicate depths or elevations A. Bottom of distribution media 28" B. Periodically saturated soil/bedrock 65" C. System separation 37" D. Required compliance separation* 36" *May be reduced up to 15 percent if allowed by Local Ordinance. 5c. “Experimental”, “Other”, or “Performance” systems built under pre-2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Intermediate Inspector License required ≤ 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. Yes No* *Any “no” answer above indicates the system is failing to protect groundwater. Describe verification methods and results: Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law. Field Copy Soil Profile Description Last updated: 1/8/10 Observation # : Equipment : Limiting Layer : Vegitation : Weather : Observation # : 1 958 Horizon Depth Shape Grade 0-14 single grain loose 14-27 single grain loose 27-55 single grain loose 55-65 single grain loose Observation # : 2 Horizon Depth Shape Grade 0-15 single grain loose 15-26 single grain loose 26-51 single grain loose 51-65 single grain loose Matrix ColorSoil Texture Redox features 10YR3/2 loamy sand 10YR3/3 Outwash loamy sand 10YR4/4 loamy coarse rocky sand 10YR4/6 loamy sand 10YR3/3 10YR4/3 Sb1 and Sb2 Bucket Auger 65" Grass Sunny Completed By : Client / Project : Landscape position : Mapped soil type : 10/11/2021 1700 Shoreline Dr Orono, MN Ende Septic Service Date Completed : loamy sand loamy sand Caretakers Home-south of trenches Elevation: Caretakers Home-north of trenches Elevation: loamy coarse rocky sand 10YR4/6 loamy sand 10YR3/2 Soil Texture Matrix Color Redox features Ende Septic Service, LLC, 24910 Territorial Road, Rogers, MN 55374 Phone: (763) 428-4489 info@endeseptic.com www.endeseptic.com Septic Inspection Map Legend 100 ft N ➤➤ N HOUSE 1000 GallonSeptic Tank Gravity FedTrench System sb1 sb2 Main Line