HomeMy WebLinkAbout10-06-2021 Septic Compliance Inspection 24910 Territorial Road, Rogers, Minnesota 55374 • 763-428-4489 info@endeseptic.com • www.endeseptic.com ______________________________________________________________________________ Project: 500 Hunter Pass Wayzata, MN A septic compliance inspection was completed, and the system is Compliant according to the MPCA codes for Chapter 7080 and local codes for the City of Orono in Hennepin County. The system the following attributes: Date Home Built: 1998 Bedrooms: 4 Date Septic Built: 1998 Septic Tanks: 2-1250-gallon dual compartment septic tank, inlet and outlet baffles in place, manhole covers to grade. Pump Tank: 1250-gallon pump tank. Pump, on/off float and alarm float in working condition during inspection. Soil Treatment: Pressure fed mound system with an 20-22 inch sand lift. Issues Found: Mound should be mowed regularly. Trees around the mound should be trimmed back. Ende Septic Service, LLC, has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. State. Sec. 155.55 (2010). The compliance inspection covers only the criteria required by Minn. Stat. Sec. 155.55, Subd. 5a (2010 and Minn. R. 7080.1500 (2011). A Compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Ende Septic Service, LLC, disclaims any use of the compliance inspection beyond determining SSTS compliance pursuant to Minn. Stat. Sec. 155.55 (2010). https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 1 of 4 Compliance inspection report form Existing Subsurface Sewage Treatment System (SSTS) Doc Type: Compliance and Enforcement Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at https://www.pca.state.mn.us/sites/default/files/wq-wwists4-31a.pdf. Property information Local tracking number: Parcel ID# or Sec/Twp/Range: 2511823310005 Reason for Inspection Property Transfer Local regulatory authority info: City of Orono Property address: 500 Hunter Pass Wayzata, MN 55391 Owner/representative: Scott Wetzel Owner’s phone: 612-333-0333 Brief system description: 2-1250 gallon septic tanks and a 1250 gallon pump tank. Effluent pumped to a mound system. System status System status on date (mm/dd/yyyy): 10/6/2021 Compliant – Certificate of compliance* Noncompliant – Notice of noncompliance (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A.04 subdivision 8. Reason(s) for noncompliance (check all applicable) Impact on public health (Compliance component #1) – Imminent threat to public health and safety Tank integrity (Compliance component #2) – Failing to protect groundwater Other Compliance Conditions (Compliance component #3) – Imminent threat to public health and safety Other Compliance Conditions (Compliance component #3) – Failing to protect groundwater System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) – Failing to protect groundwater Soil separation (Compliance component #5) – Failing to protect groundwater Operating permit/monitoring plan requirements (Compliance component #4) – Noncompliant - local ordinance applies Comments or recommendations System has been inspected many times over the last 20 years. Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: Ende Septic Service Certification number: C9206 Inspector signature: License number: L2654 (This document has been electronically signed) Phone: 763-428-4489 Necessary or locally required supporting documentation (must be attached) Soil observation logs System/As-Built Locally required forms Tank Integrity Assessment Operating Permit Other information (list): https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 2 of 4 Property Address: 500 Hunter Pass Wayzata, MN 55391 Business Name: Ende Septic Service Date: 10/6/2021 1. Impact on public health – Compliance component #1 of 5 Compliance criteria: Attached supporting documentation: System discharges sewage to the ground surface Yes* No Other: Not applicable System discharges sewage to drain tile or surface waters. Yes* No System causes sewage backup into dwelling or establishment. Yes* No Any “yes” answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: 2. Tank integrity – Compliance component #2 of 5 Compliance criteria: Attached supporting documentation: System consists of a seepage pit, cesspool, drywell, leaching pit, or other pit? Yes* No Empty tank(s) viewed by inspector Name of maintenance business: Duane's Septic Service Sewage tank(s) leak below their designed operating depth? Yes* No License number of maintenance business: L654 Date of maintenance: Existing tank integrity assessment (Attach) If yes, which sewage tank(s) leaks: Date of maintenance (mm/dd/yyyy): 9/28/2021 (must be within three years) Any “yes” answer above indicates the system is failing to protect groundwater. (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 B (1)) Tank is Noncompliant (pumping not necessary – explain below) Other: Describe verification methods and results: https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 3 of 4 Property Address: 500 Hunter Pass Wayzata, MN 55391 Business Name: Ende Septic Service Date: 10/6/2021 3. Other compliance conditions – Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? Yes* No Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? Yes* No Unknown *Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non-protective of ground water for other conditions as determined by inspector? Yes* No 3d. System not abandoned in accordance with Minn. R. 7080.2500? Yes* No *Yes to 3c or 3d - System is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: Not applicable 4. Operating permit and nitrogen BMP* – Compliance component #4 of 5 Not applicable Is the system operated under an Operating Permit? Yes No If “yes”, A below is required Is the system required to employ a Nitrogen BMP specified in the system design? Yes No If “yes”, B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is “no”, this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? Yes No b. Is the required nitrogen BMP in place and properly functioning? Yes No Any “no” answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: Operating permit (Attach) https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 4 of 4 Property Address: 500 Hunter Pass Wayzata, MN 55391 Business Name: Ende Septic Service Date: 10/6/2021 5. Soil separation – Compliance component #5 of 5 Date of installation 1998 Unknown (mm/dd/yyyy) Shoreland/Wellhead protection/Food beverage lodging? Yes No Attached supporting documentation: Soil observation logs completed for the report Two previous verifications of required vertical separation Not applicable (No soil treatment area) Compliance criteria (select one): 5a. For systems built prior to April 1, 1996, and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock. Yes No* 5b. Non-performance systems built April 1, 1996, or later or for non- performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* Yes No* Indicate depths or elevations A. Bottom of distribution media B. Periodically saturated soil/bedrock C. System separation D. Required compliance separation* *May be reduced up to 15 percent if allowed by Local Ordinance. 5c. “Experimental”, “Other”, or “Performance” systems built under pre-2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Intermediate Inspector License required ≤ 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. Yes No* *Any “no” answer above indicates the system is failing to protect groundwater. Describe verification methods and results: Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law. Fro e rty address: O , 'f, pInspectorinitials/ate: / ., G at3 4. Soil SepdrBtion—Compliance component#4 of 5 Date of instaliation: Unknown Shoreland/Wellhead protection/Food Bevere e Verification method(s): Lodging? g Yes o Soi/observa6on does not expire. P vious soil Com liance criteria: obseivations by two independent partres are s cient, un/ess site conditions have been alter d or localForsystemsbuiltpriortoApril9, 19g6, and Yes No 9uirements difier. not located in Shor land or Wel/head I Conducted soil observation(s)(Attach boring logs)Protecfion A a or not senring a food,beverage orlodging establishment.• Two previous verifications(Attach boring logs) Drainfield has at least a two-foot vertical Not applicable(Holding tank(s);no drainfield) separation distance from periodically Unable to verify(See CommentsiExplanation) saturated soil or bedrock. Other(See Comments Explanation) Nonperf nnance systems built April 1, Yes1996, or later o for nonpertormance No Comments/Explanation.• C systems/ocated in Shore/and or Wellhead a ,pA,Protection Areas or serving a food, beverage, orlodging establishment. t, K S" 4 , 0,. Drainfield has a three-foot vertical n separation distance from periodically fQ,£,Dsaturatedsoilorbedrock.* Experimental'; "Other; or Pertormance" Yes Nosystemsbuiltundepre-2008 Rules; Type 1V Indicate de ths of elevations or V systems built under 2008 Rules(7080. A. Bottom of distribution media K2350or7080.2400 (Advanced Inspector License required) u Drainfield meets the designed vertical B• Periodicall saturated soil/bedrock separation distance from periodically C. S stem se aration 38 saturated soil or bedrock. D. Re uired com liance se aration'Any "no"answer above i dicates the system isFailingtoProtectGroundwater. May be reduced up to 15 percent if allowed by LocalOrdinance. 5. Operating Permit and Nitrogen BMP*—comp iance com onent#s of s Not applicable Is the system operated under an Operating Permit? Yes o If yes ,A below is requiredIsthesystemrequiredtoemployaNitrogenBMP? Yes 10 If"yes", B below is required BMP=Best Management Practice(s)specified in the system design lf the answer to both questions is "no'; this section does not need to be completed. Com liance criteria a. Operating Permit number: Have the O eratin Permit re uirements been met? Yes No b. Is the re uired nitro en BMP in lace and ro erl functionin ?Yes No Any"no"answer indicates Noncompliance, Upgrade Requirements(Minn. Stat.§115.55)An imminent thieat to public health and safety(ITPHS)must be upgraded,replace.d,or its usediscontinuedwithintenmonthsofreceiptofthisnoticeorwithinashorterperiodifrequiredbylocalordinance.If the system is failing to protectgroundwater, the system must be upgraded,replaced, or its use discontinued within the time required by local ordinance.If an existing systemisnotfailingasdefinedinlaw, and has at least Iwo feet of design soil separation, then the system need not be upgraded,repa)r d,rep aced,oritsusediscontinued,nolwithstanding any/oca/ordinance that is more strict. This provision does not apply to systems in shoreland areas,Wellhead Protection Areas, or those used in connection with food,beverage,and lodging establishments as defrned in law. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formatswq-wwists4-31 • 1/24/1.2 Page 3 of 3 l O O C ITY of URONO 1, 4 a1 t' 'yy t rL f%' ,Municipal Off'ices i iM O P k i/. S % C `a ° Y;-'; r° <;-` G! Street Address: Mailing Address: 9 '''•''' 'Q 2150 Kelley Parkway P.O. Box 66 kEsK % Crystal Ba MN 55323•0066Orono, MN 5535fi y To: The Current Owner of Address `^ t r A SS City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The.onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No — If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tan ump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s)were last pumped out on c'j .-;? ",.2 . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleanin. Comments: Date of Inspection C '-C'- .Inspc Telephone(9 2)?49-4600 • Fa.r-(9 2)249-461h 0- I` O . ,.,.,,> O\\} . .. K ,<. . -. .-.e. .,.:,;,. r.,::._.,.. ... erca.. CITY of ORUNOI. r ,; i'r r r f',^a'. .> g., ' G, ti Municipal off'ices l ` ' .' `,`*y Street Address: °ISa-a4q-6o O Mailing Address: EgHOg' 2150 ftelley Parkway P.O. Boz 66 Orono, MN 55956 Crystal Bay, MN 55323•0066 To Current Owner: Address: SUD v r Ss City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treatment system at the above address tcas been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"An iSTS which meets ali the location,design er d construction standards of the current Orono Municipai Code. COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat W public health or safery. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located widxin a designated]00-yEar flood plain,any ISTS which may Q.[ma not mcet all the location,desiga,or construcdon stan rds of the current Orono Municipal Code and which is failing for any reason;and any TSTS with Iess than three f t of unsaturated soil or sand between e distribudon device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: 5=Pumpout not needed at-thisti ne,----___..__ _._. ____ _._.._. Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. i'a k wes last Pem ed_ . q-"L_-Ul..____a.. _ __.._. Make sure seotic tanks are aumQed throu¢h manhole aod not throu¢h white insaection uioes This allows for the aroaer cleaaeiue:---Keee-w ater seftnex-and iro filter-disch$r e out nf seutic sYstem taprolong life.flf drainfield Ask numaer to test atarm float to verifv alarm is stiit workin¢in vour house The aiarm warns owner that seata¢e is about to backua into basement T-- Insp tio se s ssing-taxilcs-could-not-be-inspected_Insp ectiQn r;c f4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. INFIELD CONDITION(8-lU): Dcaiafield_is dry,no..surfaciag.udent=_---.---___...__.____ 9 Some evidence of surfacing,not critical yet. d--Drai feld,is saturated and visihly dischargingiultte es,ef l ent to the surfa.ce. Contact the City Inspector immediately.Repairs must be completeri within 90 days. COMIVIENTS: /`` :: a1tS 4 k.. , . P _. .. .. F.,.t x.s-- -- ... S.i..r r. Z.o a S" _ t'-'-- G Date of Inspection Matt Bolterman - Septic System Inspector Note: ln the event that this inspection repon is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this repon does not guarantee or certify that an existing system will continue to function properh, but is merely an opinion of'the adequacy of the system under current conditions bascd on the available inlormation. o . o CITY of ORONO i ,, Muntcipal Offices y,}# , G Street Addross: Mailin Addross: F,+gg04' 2150 Kelley ParkwaY P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•006695d-49-4600 To Current Owner: Address: s b H fie aSs City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): , lQ"CODE SYSTEM"M ISTS which meets all the location,design and conswction standards of the current Ocono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construcGon standards of the current Orono Municipa! Code but doa meet the three foot seQaration requinment or nvo foot rcquirement for sysums installed 1996 or eartier.and which is not failing or an imminent threst to public health or safety. 3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an[STS located within a designated l00-year flood piain,any ISTS which may or may not meet all the location,design,or conswction standards of the cucrent Orono Municipal Code and which is failing for any reazon;and any[STS with less than three feet of unsaturated soii or sand between the distribution device and the limiting soil characterisdcs. TANK CONDITION(5:7: 6 Tank inspection indicates: 5 Pumpout not needed ai this time. Septic tanks must be pumped out this year (city code requires tanks to be putriped out once every 3 years. Tank was last pumped v K a w- l. Make sure se tie tanks are aumaed through manhote and not throu h white insnection aines. This Ilows for'the nroaer cleaning. 7 —Inspection risers missirig=tadks could notbe inspected: Inspection risers(4"dia.pipe)must be installed in each tank. D INFIELD 0'I'ION E&t(: __ _ _ _ ._--- ..___ _._ _ _ _ ___._ 8 Drainfeld is dry,no surfacing evident 9 Somc"evidence of surfacing,not crifical yet: " --" 10 Drai field is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector imin iiately:Rep irs miut be complet d vittiiri I0 days. COMNIENTS: S S c oc O _ 1-U 'l.t 1 V r ec J ti-6 w -;^o.5't 3 e s - aa Date of Inspection Matt Bolterman— Sep6c System Inspectoc Note: In the eveot that this inspection rcport is used W satisfy the rcquircments for a mortgage or other transfer of properry.be advised tha`i this rcport das not guarantee or certify thac an exuting rysum will continue to function properly,but is merely an opinion of the adequary of the system under current condidons based on the availabie information. Hennepin County Property Map Date: 10/6/2021 Comments: 1 inch = 50 feet PARCEL ID: 2511823310005 OWNER NAME: Scott A Wetzel PARCEL ADDRESS: 500 Hunter Pass, Orono MN 55391 PARCEL AREA: 8.23 acres, 358,641 sq ft A-T-B: Torrens SALE PRICE: $1,320,000 SALE DATA: 03/2015 SALE CODE: Warranty Deed ASSESSED 2020, PAYABLE 2021 PROPERTY TYPE: Residential HOMESTEAD: Homestead MARKET VALUE: $1,477,000 TAX TOTAL: $18,045.30 ASSESSED 2021, PAYABLE 2022 PROPERTY TYPE: Residential HOMESTEAD: Homestead MARKET VALUE: $1,495,000 This data (i) is furnished 'AS IS' with no representation as to completeness or accuracy; (ii) is furnished with no warranty of any kind; and (iii) is notsuitable for legal, engineering or surveying purposes. Hennepin County shall not be liable for any damage, injury or loss resulting from this data. COPYRIGHT © HENNEPIN COUNTY 2021 MoundArea 2-1250 GallonSeptic Tanks 1250 GallonPump Tank SupplyLine HOUSE Garage