HomeMy WebLinkAbout03-28-2019 Septic DesignJoseph Olson D.B.A.
Rusty Olson's--Soil and Percolation Testing
Joseph J. Olson--MPCA License 9810
11481 Riverview Rd. NE, Hanover, MN 55341
(763) 498-8779 Fax (763) 498-8290
Revised March 28, 2019
Swanson Homes
4315 Lakeview Court
Orono, Hennepin County
This on-site Sewage Treatment System is designed for a Type 1, five -bedroom home in accordance with
the Minnesota Pollution Control Agency Chapter 7080 and local ordinances.
The periodically saturated soils were located at 14-24 inches (mottled soil). Due to the periodically
saturated soils, a pressurized mound system with b inches of rock will need to be installed to treat the septic
effluent. The bottom of the treatment area must be located at least T above the saturated soils. This system
is designed with 6 inches of rock.
The soils at a depth of 12" have a percolation rate averaging 12.5 MPI.
All tanks need to be insulated if there is less than two feet of cover over the top of the tanks. Clean outs
must be installed on the end of the laterals for maintenance.
Use 7132- inch perforations on the laterals.
A 1250 -gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The
power supply and Switches must be located outside the manhole and pumping chamber in a weatherproof
enclosure. A warning device must be installed with light and sound devices, this is in case of a pump
failure. The manifold and supply line must have back drainage to the pumping chamber.
Keen all heavy equipment off of the proposed treatment areas before, during and after construction
The area around both sites must be fenced off by the contractor before any construction begins
With proper installation and maintenance, this system should have no problem in treating septic effluent
effectively. Nothing other than gray water, (laundry, showers, etc.) Human water and toilet tissue should be
disposed of into the septic tanks. Iron filters cannot go into the septic system. Garbage disposals are not
recommended. Additives must not be used they may cause harmful damage to your septic system. It is
recommended that you pump the septic tanks every two years.
Sincerely,
Joseph J. Olson
\ SO
\\ q7 974.k x
9
x9:5./l
9
973.5 -
o0
°=as"zl lo,,
77,-"2,4'9
2. � � \
982 4
3 � 982 9 x
-16.2
r
-984,8
j 965,6
tI"98 .9,
11.8 ea.2 y
�\ \p
\� \\ 97
97
T� '\
\ SCAL8 f- 50 "
3 x983.0
98LB
x902
i z
x11980.9
983,1
882,9
p syr, -P
969. 1 \ x9J1a \ 97711' LST&y
902,4
9 7.5 'o o .,A cap- ♦ 482.3 y j
I 1 7:+� k.. tiy. /sO,' 93s \,sa.� g9�ry56B!`
N0
979.0 0 !
ISI 981.3
960.3 Y 5 I� xb. "91a.i r7,�� 10 9800
x 66
6.6 734`-9
1y Wfa.L
974,1 J
�\976,7 978.3 x 978.
471. 0 _I
�w'� x 7,4986 1 9 IX?8 Or 97Y.�1
G`f `
99 N •. �;<`r a >a. N`gJJ - o aS l_ g3Cgl
ro
97217 h'
xy67,6\ 971.6 x 9711.5 \
rg \ 1966,4 - �7
\ ✓ \ 968 3 m c 97 2 `.
\\\x964 sr\ �'
O \ x 9k4.4 I ` x 9726
967. I �9BS \ x 965 1 - -,.?'67 a
10 I \ \ ,.� R 83+ i x: s7.7 m
\ � - 'tea$ .>�Jy x 96e.6 g
964.5Y� \ �b S\ \ �sI4 `9671 _
%7.2 l I r��L1 \ \\ �\\\\ T�v9fi]2 U _- x99A4 90.4x x97ae'�
`1x 9fi5` BL V GY, J'
�'-0Ge \ E � \ 962.9 ` 1 � ,7\
67.3
.9652 ! LTj�63.0 9166.9 x LoJ b�" 99,5
LOT I ♦ . 968.1 4 M
963 `�
964 2
7963,,9
y + x 965.3 >fYt= 966.4 47". \ \ \ \ A84. I'
r " 966.3 !-' "4'4! ,r4 x 96.6\\
r ��~
9b6.7 liRr r3, \ t-�7`O7L 7-,x 965.3.. 11 9656.
91
10 _ ` x 967 i i e, _ `f fi5 .965.6 91
ti
1970.r �- �M1 `� =G72 x 9671 \`0 '� 966.5 x z 99
o ' x 971.s �--_ `" \\�_ -•mss 968"6 7
27 .49 1--t'7z,1966.1 \ ,�,.� ��. 1969.1
\a - I 9
967.6968.2 ~ /004.9,3 \` ! -97 ],- '`x 97o. 2`07o--�
.9705 9705 >
970.1 \ log!' 73
�-
2-'2', 66 �x 970.9 1
9719 971.2 1
�ti C31"a
C R 972,7 - 0/ ! 2 \ 971.6
F
73.5 91� la
1 07/
- X974.2.
ITI
ro
Oo
N
7I
M
t9
a
r
I
i
i
N
a�
f�
2
ci
IN
2011 purple code Mound design
wwuv.5epticResource.com (vers 15.2)
Property Owner: Swanson Homes
Site Address: 4315 Lakeview Court
Comments:
Date: 3/27/2019
PID: 0611723430015
instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE!
1)bedroom Type Residential System
2) 750 GPD design flow
3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks
4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd)
Tank options: none
s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of =req's a min 62.5 ft. long rockbed
6) 10.0 ft rockbed width 62.5 ft rockbed length
7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both)
end feed manifold connection
8)laterals 60.5 feet long 21.0 perfs / lateral 63 1perfs total
(1 /2 a perf means the first pert starts at the middle feed manifold)
9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation
for this perf size Et spacing, & pipe size on line 12, max perfs/lateral = =1 line #8 must be less >
10) 4.0 doses per day (4 minimum)
11) 188 gallons per dose (treatment volume)
2.00 5x
12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement
2.00 3x
«) 95 feet of 2.0 inch supply line leads to =gallons of drainback volume
(Tip: "top feed" manifold to control the drainback)
14) 204 gallons TOTAL pump out volume (treatment + drainback)
l5) 19 feet vertical lift from pump to mound laterals, leads to a:
16) 36 GPM @ 28 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head)
17) 750 gal Dose tank (code minimum) 125fl gal Dose tank (design size / LUG req'd) at 25.49 gpi
leads to a
18) 8.0 inch swing on Demand float, or timed dosing of5.7 min ON (confirm pump rate with drawdown
(this delivers Average flow, =70% of Peak design flow)i T lhrs OFF test and adjust as necessary)
l9)[flinches
inches from bottom of tank to '"Pump OFF" float
10) inches from bottom of tank to "Pump ON" float, orP33
inches to "Timer ON" float if time dosed
21) from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed
22) 664 gallons reserve capacity (after High Level Alarm is activated)
0,45 gpd/ft2 Absorption area Soil Loading Rate, which gives a mound ratio of2.7 (minimum)
(this must match the soil boring log) desired mound ratio 2.7
15 percent site slope (0-201% range) 15 (% downslope site slope, if different than upslope)
14 inches, or 1.2 ft. to Redox or other limiting condition (need at least 12" to be a Type 1)
Treatment zone contains07inches of 0% soil credit, and ®inches of 50% soil credit. Giving a:
22 inch, or 1.8 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONSIIi
7) 27.0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:)
3) 0.0 ft. upslope and sideslope
17.0 ft. Downslope
Individual slope ratios give BERM widths (topsoil beyond rockbed) of:
upslope ratio 10 ft. upslope berm
D) 3:1 sideslope 16 ft. sideslope berms
1) 3:1 downslope 30 ft, downslope berm
Overall Dimensions: 10.0 ft. wide by 1 62.5 ft. long Rock bed
50 ft. wide by 95 ft. long Mound footprint
4" inspection pipe
18°' cover on top
/upslope berm = N. Dova'slo e berm 30
12" cover on sides
(6" loamy sap & 6" topsoil)
1.8 Clean sand lift
1.2 _ Depth to Limiting _4
ir,g Condition - - - - -
Absorotion Width 27.0
Note:
For 0 to 1% slopes, Absafption Width is meascIred from the BedegUally in both directions-.
For slopes >1%, Absarptioo Wdth is measured downhill from the upslope edge of the Ben!
Rock Bed:
1Q.0 ft. by 62.5 ft. by inches under pipe, plus 20% gives =yd-' or *1.4= 29 ton
34) Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired)
31.9 up + 170.8 downslope + 20.9 ends + 59.8 under rock = F340ydj or *1.4= 476 ton
plus 20%
Loamy Cap:
4b ft. by 91 ft. 6" deep, plus 20% gives 93 yd' or *1.4= 130 ton
Topsoil:
5Q ft. by 95 ft. 6" deep, plus 20% gives 105 yd3 or *1.4= 147 ton
hereby certify that I have completed this work in accordance with all applicable ordinances, rules and laws.
Rusty Olson"s Soil Ct Perc 810 3/27/2019
esigner Signature Company License# Date
Installer Summary
2250 gallon Septic tank (minimum) Tank options: none
3u7o Larger LdnK W1 U1 rnuiLipie comp/ Lan KS
1250 gallon Dose tank (minimum) at 25.49 gpi
36 GPM @ 28 ft. of head, Pump required
8.0 inch swing on Demand float which translates to roughly 5.0 inches of float tether length
if time dosing is required -->5.7 minutes ON time Et ®hours OFF time
20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float
23 linches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed
95 ft. of 2.0 inch supply linE with end feed manifold connection
(Tip: "top feed" manifold to control drainback)
12 inch, or 1.8 ft. Sand Lift Mound
10.0 ft. wide by 62.5 ft. long Rock bed
3 laterals 2.00 inch diameter 60.5 ft. long 3.Q ft. lateral spacing
7132 inch perfs 3.0 ft. perforation spacing
Na Effluent filter Et alarm
3 clean out Et valve box assemblies
27.0 ft.Total sand ABSORPTION width (minimum)
0.0 ft. upslope and sideslope (sand beyond rockbed, minimum)
17.Q ft. Downslope I,a,,.d . yore
Specific slope ratios give BERM widths (topsoil beyond rockbed) of:
4:1 upslope ratio 10 ft. upslope berm
3:1 sideslope 16 ft. sideslope berms
3:1 downslope 30 ft. downslope berm
4" inspection pipe
18- cover on top
Upslope berin =--,,j b Downslope berm/ 30
12" cover on sides
(6" Foamy cap & 6" topsoil)
1.8 Clean sand lift
e 1.2 Depth to Limiting
I. Absorption Width
Note:
For 0 to 1%slopes, Absorption Width is measured from the BedegUally in both directions.
For slopes %1%, Abs-oivtrora Width is measured downhill from the upslope edge of the Bed
Rock Bed: 21.0 yd or *1.4= 29 ton
Mound Sand: 340 yd or *1.4= 476 ton
Loamy Cap: 93 yd or "1.4= 130 ton
Topsoil: 105 yd3 or *1.4= 147 ton
6 inches under pipe
calculation based on 3:1!4:1 slope from top of rockbei
6" deep
6" deep
INSPECTOR CHECKLIST - mound
4.15 LaKeview Court
WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min)
50' to everything 100' to dispersal area with shallow well
PROPERTY LINES setback: 10' to everything
Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch.
LAKE /BLUFF setback: 20' for bluff. Lakes: GD _, RD , NE Protected wetland �.
Building setbacks: 10' for everything, 20' for dispersal area.
WATER LINE under pressure sc 10' to bed,tank Et sewer line. (else sewer line > 12" below)
F7Sewer line Et baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2" in 8')
(no depth reqs, clean out every 100', Sch 40 pipe)
L1Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping)
Mfg 2250 gallons none
Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles.
No effluent filter Et alarm
Dose tank risers and piping (water tight, insulated, proper depth, drainback)
Mfg 1250 gallons
A
dose pump 36 gprn 28 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF
float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length
204.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected
LABEL pump requirements and drawdown on riser or panel
Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's)
2.0 inch supply pipe: Sch40, sloped 1 /8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+.
splice box / control panel / electrical connections
flow measurement: CT, ETM, time dosed, home water meter
mound absorption area rough up
mound rock dimensions 10.0 X 62.5
Sand lift depth 22 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min)
Absorption Sand beyond rock 0.0 upslope 17.0 downslope
Bermed topsoil beyond rockbed 10 upslope 16 sideslope 30 downslope
cover depth of 12-18"+ VERIFY
3 laterals (1.2' from edge of rock)
2.00 inch pipe size (Sch40 pipe Ft fittings)
3.0 ft lateral spacing
7/32 inch perforations
3.0 ft perforation spacing.
Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY
clean outs (no hard 90's)
4" inspection pipe to bottom of rock, anchored VERIFY
Abandon existing system - if necessary
monitoring plan and type
well abandonment form - if necessary
�Re-use existing tank certification
�
| �
\
� �
\
� �
.
0
�
(U
k
k
-0
k
0
4-1
w
>
uj
�
§
4,1
M9
go
I �
\
� �
0
�
(U
lz
m
-0
0
4-1
>
uj
�
§
4,1
�
-E
fu
(U
lz
m
-0
�
-E
fu
Soil Observation Log
www.SepticResource.com vers 12.4
Owner Information
Property Owner / project: Swanson Homes Date 6/1/2014
Property Address / PID: 4315 Lakeview Court
Soil Survey Information ❑ refer to attached soil survey
Parent matl's: 0 Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock
landscape position: ❑ summit ❑ Shoulder Side slope ❑ Toe slope
soil survey map units: L41 C;2 slope 6-14 % direction- Linear -convex
Soil Log #1
❑ Boring ❑ Pit Elevation 981.8 Depth to SHWT 24 inches
Depth (in) Texture fragment % matrix calor redox color consistence grade shape
0-6
Topsoil
<35
1Oi,r41
Friable
Moderate
Blocky
6-24
Clay Loam
<35
10yr5/4
Friable
Strong
Block
24-30
Clay Loam
<35
10yr5/4
I Oy4/8,1-6/1 Oy
Friable
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigidstrong
massive
Comments:
4315 Lakeview Court Soil Log #2
❑ Boring ❑ Pit Elevation 981.8 Depth to SHWT 16 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-4
Topsoil
<35
10yr4/2
Friable
Moderate
Blocky
4-16
Clay Loam
<35
1Oyr5/4
Friable
Strang
Blocky
16-20
Clay Loam
<35
1Oyr5/4
I Oy4/8,1-6/1 Oy
Friable
Strong
Block,,
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
I strong
massive
I
4315 Lakeview Court Soil Log 93
0 Boring ❑ Pit Elevation 9$5.3 Depth to SHWT 14 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-4
Topsoil
<35
1Oyr4/2
Friable
Moderate
Blocky
4-1.1
Clay Loam
<35
1 Oyr5/4
Friable
Strong
Blocky
14-20
Clay Loam
<35
1Oyr5/4
IOy4/8,1-6/1Oy
Friable
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid I
strong I
massive
! hereby certify this work was completed in accordance with AIN 7080 and any local reqs.
Rusty Olson's Soil & Pere 814
De ' er Signature Company License #
4315 Lakeview Court Soil Log #4
Q Boring ❑ Pit Elevation 985.4 Depth to SHWT 20 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-6
Topsoil
<35
10yr4/2
Friable
Moderate
Blocky
6-20
Loam
<35
10yr4/4
Friable
Strong
Blocky
20-26
Loam
<35
10yr5/3
10y4/8,1-6/10y
Friable
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>-
firm
moderate
prismatic platy
rigid
I strong
I massive
4315 Lakeview Court Soil Log #5
P Boring ❑ Pit Elevation 977.7 Depth to SHWT 18 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-6
Topsoil
<35
10yr4/2
Friable
Moderate
Blocky
6-18
claN l,otmi
<35
tOyr5/4
FriableStrong
Blocky
18-24
Loam
<35
10yr5/4
10y4/8,1-6/10y
Friable
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
Erin
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
X50
firm
moderate
prismatic platy
rigid
strong
massive
I
1 hereby certify this work was completed in accordance with IN 7480 and any local reqs.
Rusty Olson's Soil & Perc 810
D Mier Signature Company License #
Soil Observation Log
www.SepticResource.com vers 12.4
Owner Information
Property owner / project: Swanson Homes Date 6/1/2014
Property Address / PID: 4315 Lakeview Court
Soil Survey Information ❑ refer to attached soil survey
Parent matl's: ❑ Till ❑ Qutwash ❑ Lacustrine ❑ Alluvium ❑ organic ❑ Bedrock
landscape position: ❑ Summit ❑ Shoulder 0 Side slope ❑ Toe slope
soil survey map units: L41C2 slope 6-14 % direction- Linear -Convex
Soil Log #6
Q Boring ❑ Pit Elevation 985.4 Depth to SHWT 16 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-6
Topsoil
<35
10yr4/2
Friable
Moderate
Blocky
6-24
Clay Loam
<35
10yr4/4
Friable
Strong
Blocky
24-30
Loam
<35
10yr5/3
1 Oy4/8,1-6/ 1 Oy
Friable
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weals
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
Comments:
Percolation Test Data Sheet
Lic.#810
Percolating test readings made by: Rusty Olson's Perc. starting at 1:38 P.M. On 7106114
Location: Lot 1, Blk 3
Hole number: 1
Date hole was prepared 7/05/14
Depth of hole bottom —12"� inches, Diameter of hole _6"_ inches.
Soil data from test hole:
Depth, inches
0-6"
6"-12"
Soil texture
Dark brown loam 10yr4/2
Brown loam 10yr5/4
Method of scratching side wall: Knife
Depth of gravel in bottom of hole 2 inches:
Date of initial water filling 7/05/14 depth of initial water filling 12 inches
above hole bottom.
Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon
Maximum water depth above hole bottom during tests 6 inches
Time
Time
Depth
Drop in H2O
Perc Rate
1:48
2:03
6"
2.0
7.5
2:10
2:25
6"
2.0
7.5
2:26
2:41
6"
2.0
7.5
AVERAGE PERG. RATE 7.5 MPI
Percolation Test Data Sheet
Lic.#810
Percolating test readings made by: Rusty Olson's Pere. starting at 1:38 P.M. On 7106/14
Location: Lot 1, Blk 3
Hole number: 2
Date hole was prepared 7105/14
Depth of hole bottom _12"� inches, Diameter of hole _6"— inches.
Soil data from test hole:
Depth, inches Soil texture
0-4" Dark brown loam 10yr4/2
4"-12" Brown loam 10yr5/4
Method of scratching side wall: Knife
Depth of gravel in bottom of hole 2 inches:
Date of initial water filling 7/05/14 depth of initial water filling 12 inches
above hole bottom.
Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon
Maximum water depth above hole bottom during tests 6 inches
Time
Time
Depth
Drop in H2O
Perc Rate
1:49
2:04
6"
1.0
15.0
2:19
2:24
6"
1.0
15.0
2:27
2:42
6"
1.0
15.0
AVERAGE PERC. RATE 15.0 MPI
Percolation Test Data Sheet
L_ic.#810
Percolating test readings made by: Rusty Olson's Perc. starting at 1:38 P.M. On 7106114
Location: Lot 1. Blk 3
Hole number: 3
Date hole was prepared 7105114
Depth of hole bottom _12"_ inches, Diameter of hole _6"_ inches.
Soil data from test hole:
Depth, inches
0-4"
4"-12"
Soil texture
Dark brown loam 10yr4/2
Brown loam 10yr5/4
Method of scratching side wall: Knife
Depth of gravel in bottom of hole 2 inches:
Date of initial water filling 7/05/14 depth of initial water tilling 12 inches
above hole bottom.
Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon
Maximum water depth above hole bottom during tests 6 inches
Time
Time
Depth
Drop in H2O
Perc Rate
1:50
2:05
6"
1.2
12.5
2:08
2:23
6"
1.2
12.5
2:28
2:43
6"
1.2
12,5
AVERAGE PERC. RATE 12.5 MPI
Percolation Test Data Sheet
Lic.#810
Percolating test readings made by: Rusty Olson's Pere_ starting at 1:38 P.M. On 7106114
Location: Lot 1, Blk 3
Hole number: 4
Date hole was prepared 7105114
Depth of hole bottom _12"_ inches, Diameter of hole —6"—inches.
Soil data from test hole:
Depth, inches
0-6"
6"-12"
Soil texture
Dark brown loam 10yr4/2
Brown loam 10yr5/4
Method of scratching side wall: Knife
Depth of gravel in bottom of hole 2 inches:
Date of initial water filling 7/05/14 depth of initial water filling 12 inches
above hole bottom.
Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon
Maximum water depth above hole bottom during tests 6 inches
Time
Time
Depth
Drop in H2O
Pere Rate
1:51
2:06
6"
1.0
15.0
2:07
2:22
6"
1.0
15.0
2:29
2:44
6"
1.0
15.0
AVERAGE PERC. RATE 15.0 MPI