HomeMy WebLinkAbout07-05-2018 Septic Design5 Bedroom City of Orono Septic Plan Review Reviewer: 10 X 63 Rockbed All work shall be done in full compliance 36 GPM Joseph Olson D.B.A. with all applicabie septic and zoning code. 56 # TDH Rusty Olson's--Soil and Percolation Testing Joseph J. Olson--MPCA License 4 810 1300 Pump Tank 11481 Riverview Rd. NE, Hanover, MN 55341 2250 Septic Tank (763) 498-8779 Fax (763) 498-8290 Revised July 5, 2018 Hendel Homes 1 180 Mooney Lake Drive Orono, Hennepin County This on-site Sewage Treatment System is designed for a Type I five -bedroom home in accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. The periodically saturated soils were located at 18-72 inches (mottled soil). Due to the periodically saturated soils, a pressurized mound system with 6 inches of rock will need to be installed to treat the septic effluent. The bottom of the treatment area must be located at least 3' above the saturated soils. This system is designed with 6 inches of rock All neighboring wells are greater than 100' from proposed treatment areas. The soils at a depth of 12" have a percolation rate averaging 5 MPI. A 2250 -gallon combination septic tank or its equivalent needs to be installed. AI I new tanks need to be insulated if there is less than two feet of cover over the top of the tanks. Clean outs must be installed on the end of the laterals for maintenance. A 1300 -gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device must be installed with light and sound devices; this is in case of a pump failure. A flow measurement device must be installed. Including but not limited to a water meter, event counter, running time clocks or electronically controlled dosing. With proper installation and maintenance, this system should have no problem in treating septic effluent effectively. Nothing other than gray water, (laundry, showers, etc.) Human water and toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended. Iron filters cannot go into the system. Additives must not be used they may cause harmful damage to your septic system. It is recommended that you pump the septic tanks every two years. Smcer Joseph J. Olson `�. Ali 421 91- - Co 2011 purplecode Mound Design Property Owner: Site Address: Comments: Hendel Homes 1180 Mooney Lake Drive www.SepticResource.com (vers 15.2) Date: 7/5/2018 PID: 2511823410016 KI Q\ q � o] C� C +p CL � Mj ML v ylt" tE *7t ^� L n !il 0 2011 purplecode Mound Design Property Owner: Site Address: Comments: Hendel Homes 1180 Mooney Lake Drive www.SepticResource.com (vers 15.2) Date: 7/5/2018 PID: 2511823410016 KI Q\ instructions: = = enter data = = adjust if desired = = computer calculated - DO NOT CHANGE! ) � bedroom Type I I Residential System 2) 750 GPD design flow 3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks 41 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) Tank options: none N) 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed s: 10.0 ft rockbed width 63.0 ft rockbed length 11 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) end feed manifold connection 3) =laterals 61..0 feet long 21.0 perfs / lateral 63 perfs total (1 /2 a perf means the first perf starts at the middle feed manifold) 7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation for this perf size ft spacing, Ft pipe size on line 12, max perfs/lateral = 30 line #8 must be less --> in, 4.0 doses per day (4 minimum) 11 188 gallons per dose (treatment volume) 2.00 5x i^ 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement 3) 368 feet of 2.0 inch supply line 2.00 3x leads to63 gallons of drainback volume (Tip: "top feed" manifold to control the drainback) =gallons TOTAL pump out volume (treatment + drainback) ts> 35 feet vertical lift from pump to mound laterals, leads to a: )6) 1 36 JGPM C 56 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) 17) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi Leads to a 18) F9.8 inch swing on Demand float, or timed dosing ofB7 min ON (confirm pump rate with drawdown (this delivers Average flow, =70% of Peak design flow) 9 hrs OFF test and adjust as necessary) 19)tinches inches from bottom of tank to "Pump OFF" float 20) inches from bottom of tank to "Pump ON" float, orP35 inches to "Timer ON" float if time dosed 1) from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed '-2) 663 gallons reserve capacity (after High Level Alarm is activated) 0.45 gpd/ft2 Absorption area Soil Loading Rate, which gives a mound ratio of (minimum) (this must match the soil boring log) desired mound ratioF25] =percent site slope (0-20% range) =(% downslope site slope, if different than upslope) =inches, or 2.7 ft. to Redox or other limiting condition (need at least 12" to be a Type i) Treatment zone containsF—o inches of 0% soil credit, and F 70inches of 50% soil credit. Giving a: =inch, or 1.0 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONSIII 27) 27,0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:) :8) 0.0 ft. upslope and sideslope " n ff r1 -- l— i i. .....,...,,.,rte Individual slope ratios give BERM widths (topsoil beyond rockbed) of: 9)M upslope ratio 10 ft. upslope berm M sideslope 11 ft. sideslope berms 1) downslope 20 ft. downslope berm Overall Dimensions: 10.0 ft, wide by 63.0 ft. long Rock bed 40 ft. wide by F85 ft. long Mound footprint 4" inspection pipe r— 18" cover on top U gslotae berm 1 10 1.q Il Clean sand lift _ 2,7 Depth to Limiting Limning Condition ^—-------------_— Absoration Width berm 1 20 12" cover on sides (6" loamy cap & 6" topsoil) 27.0 Note: For 4 to 1% slopes, .46soration Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the ,fed. Rock Bed: 10.0 ft. by 63.0 ft. by ©inches under pipe, plus 20% gives 21 yd' or *1,4= 29 ton sa) Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) 19.0 up + 32.3 downslope + 6.9 ends + 29.2 under rack = 105 yds or "1.4= 147 ton plus 20% Loamy Cap: =ft. by =ft. 6" deep, plus 20% gives 3o) Topsoil: 40 ft. by F 85 ft. 6" deep, plus 20% gives F–&5—]yd' or *1.4= =ton 76 yd' or *1.4= 106 ton accordance with all applicable ordinances, rules and laws. Rusty olson's Soil 8t Perc Signature Company Installer Summary 810 7/5/2018 License# Date 2250 gallon Septic tank (minimum) Tank options: none :)Uk larger Lank wrtn muwpie comps sanKs 1300 gallon Dose tank (minimum) at 25.49 gpi 36 GPM 56 ft. of head, Pump required 9.8 linch swing on Demand float which translates to roughly 5.9 inches of float tether length if time dosing is required e-> 7 minutes ON time ft ®hours OFF time 22 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float 25 linches from bottom of tank to "Hi Level Alarm" or 35 inches to "Hi levet alarm" if time dosed 368 ft. of 2.0 inch supply line with end feed manifold connection --177 (Tip: "top feed' manifold to control drainback) ,.. , v, , .v i �. aan❑ LII �. mouna 10.0 ft. wide by 63.0 ft. long Rock bed 3 laterals 2.p0 inch diameter 61.0 ft. long 3.0 ft. lateral spacing 7132 inch perfs 3.0 ft. perforation spacing No Effluent filter Et alarm 3 Iclean out Et valve box assemblies TO ft.Total sand ABSORPTION width (minimum) 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) 17.0 ft. Downslope (sand beyond rockbed, minimum) Specific slope ratios give BERM widths (topsoil beyond rockbed) of: 93:11 upslope ratio 10 ft. upslope berm sideslope 11 ft. sideslope berms downslope 20 ft, downslope berm 4" inspection pipe 18" cover on top Upslope berm [E]t I 1.0 Clean sand lift 2_7 fjFDep�th to Limiting Limiting Condition — —b-- Absorption Width berm DTI 12" cover on sides (6" loamy cap 8c 6" topsoil Mote: For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Wdthis measured downhill from the upslope edge of the Aed. Rock Bed: 21.0 yd or*1.4= 29 ton 6 inches under pipe Mound Sand: 105 yd or *1.4= 147 ton calculation based on 3:114:1 slope from top of rockbe, Loamy Cap: 65 yd or "1.4= 91 ton 6" deep Topsoil: 76 yd or *1.4= 106 ton 6" deep INSPECTOR CHECKLIST - mound 118p Mooney Lake Drive ❑ WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) 50' to everything 100' to dispersal area with shallow well PROPERTY LINES setback: 10' to everything Road setback: platted: 10' prop line. Metes Et bounds:. out of road easement, or outer ditch. LAKE / BLUFF setback: 20' for bluff. Lakes: GD , RD _, NE _. Protected wetland _. Building setbacks: 10' for everything, 20' for dispersal area. WATER LINE under pressure se 10' to bed, tank Et sewer line. (else sewer line > 12" below) Sewer line Et baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2,,in 8') (no depth reqs, clean out every 100', Sch 40 pipe) Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) mfg 2250 gallons none Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. No effluent filter Et alarm Dose tank risers and piping (water tight, insulated, proper depth, drainback) mie isuu gauons ❑ dose pump 36 gpm 56 head VERIFY PUMP CURVE 7 min ON 9 hr OFF F—]floatsetting drop 9.8 inches at 25.5 gpi "DESIGNED" 5.9 inches approx float tether length 251.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected LABEL pump requirements and drawdown on riser or panel Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. splice box / control panel / electrical connections flow measurement: CT, ETM, time dosed, home water meter mound absorption area rough up mound rock dimensions 10.0 X 63.0 Sand lift depth 12 inches. (Jar test : 2" sand leaves < 1 /8" silt after 30 min) Absorption Sand beyond rock 0.0 upslope 17.0 downslope Bermed topsoil beyond rockbed 10 upslope 11 sideslope 20 downslope cover depth of 12-18"+ VERIFY 3 laterals (1-2' from edge of rock) 2.00 inch pipe size (Sch40 pipe Ft fittings) 3.0 ft lateral spacing e 7/32 inch perforations 3.0 ft perforation spacing Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY clean outs (no hard 90's) 4" inspection pipe to bottom of rock, anchored VERIFY Abandon existing system - if necessary =Re -use existing tank certification monitoring plan and type well abandonment form - if necessary z re x YCL @ IZZ ¢- a a �o 0 f— cm v c tj c cc H CL z re Y IZZ ¢- a a �o 0 Y cm v c tj c cc H Soil Observation Log Owner Information Property Owner / project: Mooney Lake Preserve Property Address / PID: Lot 7, Blk 1 u Soil Survey Information ❑ refer to attached soil survey Parent matl's: Q Till ❑ Outwash ❑ lacustrine ❑ Alluvium a Q f0 � f— � M u L22C'2 slope 5-8 % =fn 0 I L w t [5 a qJ W E ro v W o s v75 E `~ c 4-J a o � � m Soil Observation Log Owner Information Property Owner / project: Mooney Lake Preserve Property Address / PID: Lot 7, Blk 1 u V4. W QJ T__ c, VI a O r CL � GD C o�x ay www.SepticResource.com vers 12.4 Date 4/7/2015 Soil Survey Information ❑ refer to attached soil survey Parent matl's: Q Till ❑ Outwash ❑ lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock f0 � f— � Toe slope P u L22C'2 slope 5-8 % .Q I V4. W QJ T__ c, VI a O r CL � GD C o�x ay www.SepticResource.com vers 12.4 Date 4/7/2015 Soil Log #1 Q Boring ❑ Pit Elevation 1047.3 Depth to SHWT 42" )th (in) Texture fragment % matrix color redox color consistence grade shape 0-4 Topsoil 135 F 10yr3/2 Loose Loose Single «rain Soil Survey Information ❑ refer to attached soil survey Parent matl's: Q Till ❑ Outwash ❑ lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock landscape position: ❑ Summit ❑ Shoulder R] Side slope ❑ Toe slope P soil survey map units: L22C'2 slope 5-8 % direction- lineal Soil Log #1 Q Boring ❑ Pit Elevation 1047.3 Depth to SHWT 42" )th (in) Texture fragment % matrix color redox color consistence grade shape 0-4 Topsoil 135 F 10yr3/2 Loose Loose Single «rain 4-8 Loam <35 IOyr4/4 1 Oy4/8,1-6/1 Oy Firm Strong Blocky 8-32 Clay Loam <35 10yr5/4 pth (in) Firm Strong Blocky 38-42 Clay Loam <35 1Oyr5/4 Topsoil Firm Strong Prismatic 42-54 Loam <35 1Oyr6/4 10y4/8,1-6/1Oy Firm Strong Prismatic Comments: 7, Blk 1 Soil Log #2 <35 1Oyr5/4 1 Oy4/8,1-6/1 Oy Firm Q Boring 0 Pit Elevation 1047.3 Depth to SHWT 32" pth (in) Texture fragment % matrix color redox color consistence grade shape 04 Topsoil <35 1Oyr3/2 Loose Loose Single grain 4-8 Loam <3.5 1Oyr4/4 Firm Strong Blocky 8-32 Clay Loam <35 10yr5/4 Firm Strong Blocky 32-48 Loam <35 1Oyr5/4 1 Oy4/8,1-6/1 Oy Firm Strong Prismatic <35 loose loose single grain 35-50 friable weak granular blocky X50 firm moderate prismatic platy rigidstrong massive Lot 7, Blk 1 Soil Log #3 0 Boring ❑ Pit Elevation 1046.3 Depth to SHWT 32" Depth (in) Texture fragment % matrix color redox color consistence grade shape 0-4 1 Topsoil 1 <35 1Oyr3/2 Loose Loose Single grain I hereby certi this work was completed in accordance with W 7080 and any local reqs. Rusty Olson's Soil & Perc signer Signature Company 810 License 7, Blk 1 Soil Log #4 0 Boring ❑ Pit Elevation 1046.3 Depth to SHWT rth (in) Texture fragment % matrix color redox color consistence grade shape 0-4 Topsoil <35 10yr3/2 Loose Loose Single grain 4-10 Loam <35 10-24 Clay Loam <35 24-60 1 Loam 1 ,35 I Oyr4/4 I I Finn IOyr5/4 I Oyr5/4 I IFirm Strong (Blocky 60-72 Loam <35 10yr6/4 Firm 4-8 Loam <35 10yr4/4 Firm Strong Blocky $-24 Clay Loam <35 I Oyr5/4 Depth (in) Firm Strong Blocky 24-32 Loam <35 10yr5/4 <35 Firm Strong Prismatic 32-48 Loam <35 10yr6/4 lOy4/8,1-6/l0y Firm Strong Prismatic I hereby certi this work was completed in accordance with W 7080 and any local reqs. Rusty Olson's Soil & Perc signer Signature Company 810 License 7, Blk 1 Soil Log #4 0 Boring ❑ Pit Elevation 1046.3 Depth to SHWT rth (in) Texture fragment % matrix color redox color consistence grade shape 0-4 Topsoil <35 10yr3/2 Loose Loose Single grain 4-10 Loam <35 10-24 Clay Loam <35 24-60 1 Loam 1 ,35 I Oyr4/4 I I Finn IOyr5/4 I Oyr5/4 I IFirm Strong (Blocky 60-72 Loam <35 10yr6/4 Firm Strong Lot 7, Blk 1 Soil Log 45 2 Boring ❑ pit Elevation 1046.8 Depth to SHWT Depth (in) Texture fragment % matrix color redox color consistence grade 04 Topsoil <35 10yr3/2 I Loose E.se 4-10 1 Loam I <35 1 10yr4/4 I IFirm IStrong IBlocky grain 10-24 Clay Loam <35 10yr5/4 Parent matl's: Firm Strong Blocky 24-60 Loam <_ 5 10v15 Firm Strong Prismatic 60-72 Loam <35 10yr6/4 <35 Firm Strong Prismatic I hereby certify this work was completed in accordance with MN 7080 and any local reqs. Rusty Olson's Soil testing WgKer Signature Company 810 License # Soil Observation Log www.SenticResnarce corn vers 1? Owner Information Owner / project: Mooney Lake Preserve Date 4/7/2015 Address / PID: Lot 7, Blk I Soil Log #6 0 Boring ❑ Pit Elevation 1044.1 Depth to SHWT 18" Depth (in) Texture fragment % matrix color redox color consistence grade shape Soil Survey Information ❑ refer to attached soil survey Parent matl's: Q Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock landscape position: ❑ Summit ❑ Shoulder Side slope ❑ Toe slope soil survey map units: L22C2 slope 5-8 % direction- Lineal Soil Log #6 0 Boring ❑ Pit Elevation 1044.1 Depth to SHWT 18" Depth (in) Texture fragment % matrix color redox color consistence grade shape 0-4 Topsoil <35 10yr3/2 Loose Loose Single grain 4-10 Loam <35 10yr4/4 Firm Strong Blocky 10-18 Clay Loam <35 10yr5/4 Firm Strong stocky 18-24 Clay Loam <35 10yr5/4 IOy4/8,1-6/10y Firm Strong prismatic landscape position: ❑ Summit ❑ ShoulderSide slo ❑ pe � j Toe slope soil survey map units: L22C2 slope 12 % direction -linear Comments: Soil Observation Log www.SepticResource.com vers 12.4 Owner Information Property Owner / project: Mooney Lake Preserve Date 6/24/2015 Property Address / PID: Lot 7, Blk 1 Soil Log #7 0 Boring ❑ Pit Elevation 1053 Depth to SHWT 20" )th (in) Texture fragment % matrix color redox color consistence grade shape 0-6 Topsoil <35 10yr3/2 Loose Loosesingle grain 6-12 I Clay Loam I <35 I 10yr4/3 I (Friable IStrong (Blocky 12-20 I Clay Loam I <35 + 10yr5/4 I IFirm 20-26 1 Clay Loam I 5 I 10yr5/4 I 10y4/8,1 -6/10y IFirm IStrong IPrismatic Soil Survey Information ❑ refer to attached soil survey Parent matl"s: ❑r Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic © Bedrock landscape position: ❑ Summit ❑ ShoulderSide slo ❑ pe � j Toe slope soil survey map units: L22C2 slope 12 % direction -linear Soil Log #7 0 Boring ❑ Pit Elevation 1053 Depth to SHWT 20" )th (in) Texture fragment % matrix color redox color consistence grade shape 0-6 Topsoil <35 10yr3/2 Loose Loosesingle grain 6-12 I Clay Loam I <35 I 10yr4/3 I (Friable IStrong (Blocky 12-20 I Clay Loam I <35 + 10yr5/4 I IFirm 20-26 1 Clay Loam I 5 I 10yr5/4 I 10y4/8,1 -6/10y IFirm IStrong IPrismatic <35 ❑ Boring ❑ Pit Elevation 1053 Depth to SHWT 22" Depth (in) Texture fragment % matrix color redox color consistence grade shape 0-6 loose loose single grain 35-50 Loose Loose friable weak granular block, >50 IOyr4/3 firm moderate prismatic platy 14-22 Clay Loam <35 rigid strong massive Comments: Lot 7, Blk 1 Soil Log #8 ❑ Boring ❑ Pit Elevation 1053 Depth to SHWT 22" Depth (in) Texture fragment % matrix color redox color consistence grade shape 0-6 Topsoil <35 10yr3/2 Loose Loose Single grain 6-14 Clay Loam <35 IOyr4/3 Friable Strong Blocky 14-22 Clay Loam <35 1 Oyr5/4 Friable Strong Block) 22-30 Silt <35 10yr5/4 10y4/8,1 -6/10y Friable Strong Prismatic Lot 7, Blk 1 Soil Log #9 Boring ❑ Pit Elevation 1053 Depth to SHWT 20" Depth (in) Texture fragment % matrix color redox color consistence grade Shape 0-8 Topsoil <35 1Oyr3/2 Loose Loose Single grain 8-14 Loam <35 IOvr43 Friable Strong Blocky 14-18 Clay Loam <35 10\i-5 4 Finn Strong Prismatic 18-24 Clay Loam <35 1Oyr5/4 IOy4/8,1-6/IOy Firm Strong Prismatic I hereby certify this work was completed in accordance with MN 7080 and any local reqs. Rusty Olson's Soil & Pere. 810 Designer,Kfature Company License # Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Pere. starting at 1:20 P.M. On 417115 Location: Lot 7, Blk 1 Depth Hole number: 1 Pere Rate Date hole was prepared: 416115 1:48 Depth of hole bottom _12"_ inches, Diameter of hole _6"_ inches. Soil data from test hole: 1:55 Depth, inches Soil texture 0-4" Dark Brown Loam 10yr312 4"-8" Brown loam 10yr414 8"-12" Brown clay loam 10yr514 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 416115 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Pere Rate 1:33 1:48 6" 2.0 7.5 1:55 2:10 6" 1.9 7.9 2:11 2:26 6" 1.8 8.3 AVERAGE PERC, RATE 7.9 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 1:20 P.M. On 417115 Location: Lot 7, Blk 1 Depth Hole number: 2 Perc Rate Date hole was prepared: 416/15 1:49 Depth of hole bottom _12"_ inches, Diameter of hole 6" inches. Soil data from test hole: 1:54 Depth, inches Soil texture 04" Dark Brown Loam 10yr312 411-8" Brown loam 10yr414 8"-12" Brown clay loam 10yr514 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches - Date of initial water filling 416115 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 1:34 1:49 6" 2.2 6.8 1:54 2:09 6" 2.1 7.1 2:12 2:27 6" 2.1 7.1 AVERAGE PERC. RATE 7.0 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 120 P.M. On 417115 Location: Lot 7, Blk 1 Hole number: 3 Date hole was prepared: 4/6/15 Depth of hole bottom _ 12", inches, Diameter of hole 6"_ inches. Soil data from test hole: Depth, inches Soil texture 0-4" Dark Brown Loam 10yr312 4"-8" Brown loam 10yr414 8"-12" Brown clay loam 10yr5l4 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 416115 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 1:35 1:50 6" 5.5 2.7 1:53 2:08 6" 5.5 2.7 213 2:28 6" 5.5 2.7 AVERAGE PERC. RATE 2.7 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 1:20 P.M. On 4/7/15 Location: Lot 7, Blk 1 Hole number: 4 Date hole was prepared: 4/6/15 Depth of hole bottom _12"_ inches, Diameter of hole _6" inches. Soil data from test hole.- Depth, ole:Depth, inches Soil texture 0-4" Dark Brown Loam 10yr3/2 4"-10" Brown loam 10yr4/4 10"-12" Brown clay loam 10yr5/4 Method of scratching side wall: Knife Depth of graved in bottom of hole 2 inches: Date of initial water filling 4/6/15 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 1:36 1:51 6" 5.5 2.7 1:52 2:07 6" 5.5 2.7 2:14 2:29 6" 5.5 2.7 AVERAGE PERG. RATE 2.7 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Pere. starting at 10:40 A.M. On 6/25/15 Location: Proposed Lot 7,6I1k 1 Hole number: 5 Date hole was prepared: 6124/15 Depth of hole bottom _12"_ inches, Diameter of hole 6" inches. Soil data from test hole: Depth, inches Soil texture 0-6" Dark Brown Loam 10yr312 6"-12" Brown clay Loam 10yr514 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 6124/15 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches 10:53 11:08 6" 2.8 5.3 11:11 11:26 6" 2.7 5.5 11:27 11:42 6" 2.7 5.5 AVERAGE PERC. RATE 5.4 MPI Percolation Test Data Sheet LIC.*?J-I U Percolating test readings made by: Rusty ©lson's Perc. starting at 10:40 A.M. On 6125/15 Location: Proposed Lot 7,8Ik 1 Hole number: 6 Date hole was prepared: 6/24115 Depth of hole bottom _12 inches, Diameter of hole 6"_ inches. Soil data from test hole: Depth, inches Soil texture 0-6" Dark Brown Loam 10yr3/2 6"-12" Brown clay Loam 10yr5/4 Method of scratching side wail: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 6/24115 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches 1 U:54 11:09 6" 2.6 5.8 11:10 11.25 6" 2.5 6.0 11:28 11:43 6" 2.5 6.0 AVERAGE PERC, RATE 5.9 MPI