HomeMy WebLinkAbout12-14-2018 Septic Compliancez Minnesota Pollution
Control Agency Compliance Inspection Form
ti
520 Lafayette Road North Subsurface Sewage Treatment Systems (SSTS)
St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement
Inspection results based on Minnesota Pollution Control Agency (MPCA) For local tracking purposes:
requirements and attached forms — additional local requirements may also apply. New System
System Status
System status on date (mm/dd/yyyy):
12/14/2018
® Compliant — Certificate of Compliance
(Valid for S years from report date, unless shorter time
frame outlined in Local Ordinance.)
Reason(s) for noncompliance (check all applicable)
❑ Noncompliant — Notice of Noncompliance
(See Upgrade Requirements on page 3.)
❑ Impact on Public Health (Compliance Component #1) — Imminent threat to public health and safety
❑ Other Compliance Conditions (Compliance Component #3) — Imminent threat to public health and safety
❑ Tank Integrity (Compliance Component #2) — Failing to protect groundwater
❑ Other Compliance Conditions (Compliance Component #3) — Failing to protect groundwater
❑ Soil Separation (Compliance Component #4) — Failing to protect groundwater
❑ Operating permit/monitoring plan requirements (Compliance Component #5) — Noncompliant
Property Information
Parcel ID# or Sec/Twp/Range:
Property address: 1140 Wyndmere Road Reason for inspection: New System
Property owner: Owner's phone:
or
Owner's representative:
Local regulatory authority:
Metro General Service Inc.
of Orono
Brief system description: Type I Mound
Comments or recommendations:
Mound Repair
Certification
Representative phone:
763-428-2938
Regulatory authority phone: 952-249-4600
I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system, inadequate maintenance, or future water usage.
Inspector name: Roger Peitso
Business name: Olt
r
Inspector signature:
Necessary or Locally Required Attachments
M Soil boring logs
❑ Other information (list):
® System/As-built drawing
Certification number: #6683
License number:
Phone number: 952-249-4625
❑ Forms per local ordinance
www.pca.state.mn.us 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31b • 614114 Page 1 of 3
Property address: 1140 Wyndmere Road
1. Impact on Public Health — Compliance component #1 of 5
Compliance criteria:
System discharges sewage to the ❑ Yes ® No
round surface.
System discharges sewage to drain ❑ Yes ® No
the or surface waters.
System causes sewage backup into ❑ Yes ® No
dwelling or establishment.
Any "yes" answer above indicates the
system is an imminent threat to public
health and safety.
Comments/Explanation:
New system installation
2. Tank Integrity — Compliance component #2 of 5
Hance criteria:
System consists of a seepage pit, ❑ Yes ® No
cesspool, drywell, or leaching pit.
Seepage pits meeting 7080.2550 may be
compliant if allowed in local ordinance.
Sewage tank(s) leak below their ❑ Yes ® No
designed operating depth.
If yes, which sewage tank(s) leaks:
Any "yes" answer above indicates the
system is failing to protect groundwater,
Comments/Explanation:
Brand new tanks
Inspector initials/Date: RLP 1 12/14/2018
(mm/dd/yyyy)
Verification method(s):
❑ Searched for surface outlet
❑ Searched for seeping in yard/backup in home
❑ Excessive ponding in soil system/D-boxes
❑ Homeowner testimony (See Comments/Explanation)
❑ "Black soil' above soil dispersal system
❑ System requires "emergency" pumping
❑ Performed dye test
❑ Unable to verify (See Comments/Explanation)
® Other methods not listed (See Comments/Explanation)
Verification method(s):
❑ Probed tank(s) bottom
❑ Examined construction records
❑ Examined Tank Integrity Form (Attach)
❑ Observed liquid level below operating depth
❑ Examined empty (pumped) tanks(s)
❑ Probed outside tank(s) for "black soil'
❑ Unable to verify (See Comments/Explanation)
® Other methods not listed (See Comments/Explanation)
3. Other Compliance Conditions —Compliance component #3 of 5
a. Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound. ❑ Yes* ® No ❑ Unknown
b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety. ❑ Yes* ® No ❑ Unknown
*System is an imminent threat to public health and safety.
Explain:
c. System is non -protective of ground water for other conditions as determined by inspector. ❑ Yes* ® No
*System is failing to protect groundwater.
Explain:
www.pca.state.mn.us 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31b • 614114 Page 2 of 3
Property address: 1140 Wyndmere Road
Inspector initials/Date: RLP 1 12/14/2018
(mm/dd/yyyy)
4. Soil Separation — Compliance component #4 of 5
Date of installation: 12/14/2018 ❑ Unknown Verification method(s):
(mm/ddlyyyy)
Shoreland/Wellhead protection/Food beverage ❑ Yes ® No
lodging?
Compliance criteria:
For systems built prior to April 1, 1996, and
not located in Shoreland or Wellhead
Protection Area or not serving a food,
beverage or lodging establishment:
Drainfield has at least a two -foot vertical
separation distance from periodically
saturated soil or bedrock.
Non-performance systems built April 1,
1996, or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage, or lodging establishment:
Drainfield has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
"Experimental, "Other, or "Performance"
systems built under pre -2008 Rules; Type IV
or V systems built under 2008 Rules (7080.
2350 or 7080.2400 (Advanced Inspector
License required)
Drainfield meets the designed vertical
separation distance from periodically
saturated soil or bedrock.
❑ Yes ❑ No
Soil observation does not expire. Previous soil
observations by two independent parties are sufficient,
unless site conditions have been altered or local
requirements differ.
® Conducted soil observation(s) (Attach boring logs)
❑ Two previous verifications (Attach boring logs)
❑ Not applicable (Holding tank(s), no drainfield)
❑ Unable to verify (See Comments/Explanation)
❑ Other (See Comments/Explanation)
® Yes ❑ No Comments/Explanation:
New system installation
❑ Yes ❑ No
Any "no" answer above indicates the system is
failing to protect groundwater.
Indicate denths or elevations
A. Bottom of distribution media
B. Periodically saturated soil/bedrock
C. System separation
D. Required compliance separation*
*May be reduced up to 15 percent if allowed by Local
Ordinance.
5. Operating Permit and Nitrogen BMP* — Compliance component #5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required
Is the system required to employ a Nitrogen BMP? ❑ Yes ❑ No If "yes", B below is required
BMP = Best Management Practice(s) specified in the system design
If the answer to both questions is "no", this section does not need to be completed.
Compliance criteria
a. Operating Permit number:
Have the Operatinq Permit requirements been met?
b. Is the required nitrogen BMP in place and properly fu
Any "no" answer indicates Noncompliance.
❑ Yes ❑ No
riamookilne
Upgrade Requirements (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use
discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect
ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system
is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or
its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law.
www.pca.state.mn.us 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31b • 614114 Page 3 of 3
city of Orono Septic Asbuilt Form
Q.ilrfina Use: Residence
Address: 1140 Wyndmere Road License # L1546 Date: 5/14/2018
Installer: Metro General Services Inc # 4
Septic Tanks: 2250 pump Tank: 1250 Date Finaled: Bedrooms
El III F-71 Mound [—]Trenches 0 Pressure Bed Mother
System Type: E-x� I I � I
ces to tank Risers. Use two(2) points from a permanent
Draw detailed diagram with measurements indicating distances to tank Risers. Use tVVUtr-j
Istructure. Show locations of drop Boxestrenches
3
4*332
z
6
7__
8---
9--
10
11
12
PMPMTY LINE
use" arm
ws
NORTH
Area
Reau"
fi; pro
Pump Tank
AN Elevations Will!
172.
Proposed 60. upptv
be dW Upon
Una
ampka" of
excavilan of
Propoiod 25W
Walkout
Ga#w Sefdc
Proposed
Proposed 2W Main Lkla Tonk
F—F
House
(P out
Soil Observation Log
www.SeptieResource.com vers 12.4
Owner Information
Owner / project: David Gange Date 11/1/2017
Address / PID: 1140 Wyndmere Rd.
Soil Survey Information refer ti) attached soil survey
Parent matl's: R1 Till ❑ Outwash ❑ Lacusrrine ❑ Alluvium ❑ Organic [] Bedrock
landscape position: ❑ Summit ❑ Shoukier ❑ Side slope ❑ Toe slope
soil survey map units: L22D2 slope 12 % direction- downhill
L22C2
Soil Log #1
F11 Boring ❑ Pit Elevation Depth to SHWT 15"
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-10
sandy loam
<35
10YR3/3
Loose
Moderate
granular
10-17
sandy loam
<35
10YR4/6
Friable
Weak
granular
17-26
sandy loam
X35
10YR3/4
Loose
Loose
single grain
26-36
sand
<35
10YR3/4
5YR5/8
Loose
Loose
Single grain
<35
loose
loose
single grain
friable
weak
granular blocky
35-50
firm
moderate
prismatic platy
>50
rigid
strong
massive
Comments:
1140 Wyndmere Rd. Soil IAg #2
0 Boring ❑ Pit Elevation Depth to SHWT 24"
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-11
sandy loam
<35
10YR3/2
Friable
Weak
Granular
11-17
sandy loam
<35
10YR4/6
Friable
Weak
Granular
17-21
loamy sand
<35
IOYR4/6
Friable
Weak
Granular
21-34
sand
<35
10YR3/4
Loose
Loose
Single grain
34-42
loamy sand
<35
IOYR3/4
5YR5/8
Friable
Weak
Granular
1140 Wyndmere
Rd. Soil Log #3
Q Boring ❑ Pit Elevation Depth to SHWT
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-7
sandy loam
<35
IOYR3/3
Friable
Weak
Granular
7-18
sandy loam
<35
IOYR4/6
Friable
Weak
Granular
18-22
sand
<35
I OYR4/6
5yR5/8
Loose
Loose
Single grain
22-28
sand
<35
10YR3/4
5YR5/8
Loose
Loose
Single grain
<35
35-50
>50
loose
fi iable
fir In
rigid
loose
weak
moderate
strong
single grain
granular blocky
prismatic platy
massive
I hereby certify this work was completed in accordance with AdN 7080 and any local reqs.
Designer Signature
Ende Septic Service C9206
Company License #
1140 W dmere Rd. Soil Log #4
RI Boring ❑ Pit Elevation Depth to SHWT 18"
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-6 loam
<35
10YR3/2
Friable
Moderate
Blocky
6-18 loam
<35
10YR4/4
Friable
Moderate
Blocky
18-22 clay loam
<35
10YR4/6
5YR5/8
Loose
Moderate
Blocky
22-30 clay loam
<35
10YR5/4
5YR5/8
Friable
Strong
Blocky
<35
loose
loose
single grain
friable
weak
granular blocky
35-50
firm
moderate
prismatic platy
>50
rigid
strong
massive
1140 W dmere Rd. Soil Log #5
Q Boring ❑ Pit Elevation Depth to SHWT 20"
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-11
loam
<35
10YR3/2
Loose
Weak
Blocky
11-20
clay loam
<35
10YR4/4
Friable
Strong
Blocky
20-30
clay loam
<35
10YR4/6
5YR5/8
Friable
Moderate
Blocky
�5
loose
loose
single grain
35-50
friable
weak
granular blocky
firm
moderate
prismatic platy
>50
rigid
strong
massive
<35
loose
loose
single grain
friable
weak
granular blocky
35-50
firm
moderate
prismatic platy
>SO
rigid
among
massive
1 hereby certify this work was completed in accordance with AN 7080 and any local reqs.
-- Ende Septic Service C9206
Designer Signature Company License #
UNIVERSITY
OF MINNESOTA
96.0
Septic System Management Plan
for Above Grade Systems
The goal of a septic system is to protect human health and the environment by properly treating wastewater
before returning it to the environment. Your septic system is designed to kill harmful organisms and remove
pollutants before the water is recycled back into our lakes, streams and groundwater.
This management plan will identify the operation and maintenance activities necessary to ensure long-
term performance of your septic system. Some of these activities must be performed by you, the
homeowner. Other tasks must be performed by a licensed septic maintainer or service provider. However,
it is YOUR responsibility to make sure all tasks get accomplished in a timely manner.
The University of Minnesota's Septic System Owner's Guide contains additional tips and recommendations
designed to extend the effective life of your system and save you money over time.
Proper septic system design, installation, operation and maintenance means safe and clean water!
Property Owner David Gange Email
Property Address 1140 Wyndmere Rd. Orono property, ID2611823410014
System Designer Ende Septic Service Contact Info 763-428-4489
System Installer /7e,b �o 6 ���U�� �r2UV`lGP/ �� Contact Info -70-1[Z8 Z��g
Service Provider/Maintainer Ende Septic Service Contact Info 763-428-4489
Permitting Authority City of Orono Contact Info 'g5z--Z-�,?— X600
Permit# �5618-- 9)ng0041- Date Inspected )z �/�`4
Keep this Management Plan with your Septic System Owner's Guide. The Septic System Owner's Guide
includes a folder to hold maintenance records including pumping, inspection and evaluation reports. Ask
your septic professional to also:
• Attach permit information, designer drawings and as -built of your system, if they are available.
• Keep copies of all pumping records and other maintenance and repair invoices with this document.
• Review this document with your maintenance professional at each visit; discuss any changes in product
use, activities, or water -use appliances.
For a copy of the Septic System Owner's Guide, visit www.bookstores.umn.edu and search for the word
"septic" or call 800-322-8642.
For more information see http://septic.umn.edu
Version: August 2015
-1-