HomeMy WebLinkAboutPoint of Sale Inspection Form - Compliancy Expires 09-15-2031Task 55125 Date Called in 08/17121 Date Scheduled 08/18/21 City Of Orono Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form Property Address: 13211 Bayside Rd PID: Owner Information Name: James & Tracey Lundell Mailing Address: (if different from Property) EXPIRES: -15- oZ031 Phone: 952-388-7114 Email: I lundy123@aol.com Ins ect r Information Name: Standard Company/ Organization 4-/Licensenumber: (/ Roof Drains Roof drains and leaders Roof drains should not be connected to the sanitary Phone: Email: sewer but should discharge to the ground outside of a building. If the roof Inspection System Standard Pass Fail Roof Drains Roof drains and leaders Roof drains should not be connected to the sanitary sewer but should discharge to the ground outside of a building. If the roof drains are connected to the sanitary sewer, disconnect them, plug any open connections to the sanitary sewer using a non -shrink permanent material, and redirect the roof drains onto the ground outside the building. Foundation Foundation drains are underground pipes that collect storm water from Drains around the base of a building and into a sump basket, where it is then pumped outside of the building. Foundation drains should not be connected to the sanitary sewer. Sump Pumps Sump pumps are designed to capture surface or ground water that enters basements or crawl spaces and pump it away from the house. The basic sump system includes drain tile, a sump pit, a sump pump, a float or switch, and a drain line. Sump pumps should not be connected to the sanitary sewer. Sewer Service Sanitary Sewer Inflow & Infiltration (I/I) Compliance inspection Sanitary Line Sewer Lines. All sanitary sewer lines serving Property, from the house to the main line, shall be in a safe and functional condition and shall be free from all leaks, failures including but not limited to partially collapsed sections or tree root intrusion. The sanitary sewer lines shall meet the City Code standards and specifications, (Details on back of this sheet Notes: Toilet Removed o Yes ffNo For Inspection: City Review Inspectors Signature: Date: / Owners Signature: Date: City Review Compliant q Corrective Action Required Certificate of Compliance Expires: q-jr0,j0Aj Corrective Action Due by: it, a ba Date: q -leo- 8Odl Signature: Name: Service Line Inspection Details Weather Conditions: Approximate Depth of Service tr PI/C Type and Size of Service W\ WG Overall Condition of Service Pipe Please note all connections, fittings, points of concern on service line including infiltration, tree root, cracks, misaligned joints, etc. This report must include a digital copy of the televising. Feet Comment Example: 0 Start for 4" cleanout in NE corner of Basement 1-10 Misaligned joint —Infiltration ell Notes: Cap 01L t t,4 rM