Loading...
HomeMy WebLinkAboutSeptic/sewer info �����C�._ :�'��._��:�. � O� . 0 '�,� 0 � � � � CITY of ORONO ,a ' ��l�`�'-y �+ 4 ,r� �� �,,� '�, �; ��, ��ti Municipal Offices _ �t ��'�,, {` '��,�''.� Street Address: Mailing Address: .q ���,� .g, Jt'ESKp 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 October 28, 1997 Dear Project Area Residents; Installation of the sanitary sewer lines and lift stations is complete for the Bracketts Pointl Bay Ridge sanitary sewer project. The system will be operational and available for residential connections as of Monday,November 3rd. All connections to the system must be completed by a state licensed plumber. A City permit for connection must be obtained by the licensed plumber who is going to complete the work. Payment of the Metropolitan Council Environmental Services SAC (Sewer Availability Charge) must be made when the sewer connection permit is issued. This charge is for the metropolitan sewer system downstream capacity that has been reserved for new sanitary sewer connections. According to Orono City Code, all connections to the sewer system must be made within 16 months of the official date that the system is operational for residential connections. Based on the availability date of November 3rd 1997, the deadline for connection to the system is March 3rd 1999. Effectively, this means that all connections will need to be completed before the end of the 1998 construction season. Restoration of the project area is scheduled for this fall with the final surface course of asphalt pavement scheduled for completion in 1998. Thank you for your assistance in this matter and patience and understanding during construction of this project. Please contact myself or Tom Kellog with Boonestro Engineers, Phone 604-4863, should you have any questions or concerns about the project. Sincerely � ,X�C � x� �� Greoory A. Gappa Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT � � INSPECTION REPORT ti ���kESH��'�G Owner• (.//'!Y�'r1 � KP►�P� Address• � �,{ � Permit #'s: Dates: /'`{�S Contractors: � � City ordi.nance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked belou. (This is l�l an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface uaters. 2 "CONFORMING SYSTEM��-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or 1� has not been identified at this time. tf the limiting soil characteristic has not been identified, this �lassification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Purtipout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. � System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be punped 10 Inspecti'��on p pe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): � Dr field inspection indicates: Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,uater table,etc.): � COMMENTS:;��e. ��-�;c. -�n� w�rr' �o?�-� l�G)rY� ��u�t� r�v��SoioYl� —r e -- Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or cert�fy that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prEmises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office eox 66 Crystal eay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT „� � INSPECTION REPORT ti �t9kESHa4�G Owner: �/�/� /'�C�iC��� Addres s: /�['S�� ��I/ /��(�.�� �C(,�'a Permit #'s: � Dates: �fi��� Contractors: ���/71f'�/,��C��+ City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked belou. (This is fX1 an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and uhich is failing for any reason; and any svstem uith less than 3 feet of_�„s,�t�,l��ted soil or cand � between the distribution device and the limiting soil char��T€Fl ic3`�'s. —���1r� �,,,�,,,�1 �v ��j�_9�. '�— - -�t% (P�i[ (The limiting soil characteristic�_has or [ ] has not been identifie a this ime. If the�limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK COIdDITION (5-10): � T� inspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids acc�unulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. 7anks must be pumped out uithin 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. if tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Drp�t�field inspection indicates: CIV Drainfield is dry, no surfacing evident. T`2 Some evidence of surfacing, not c n tical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE fACTORS (slope,setbacks,etc.): r POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �/�r.��L1� COMMENTS: ; / �, , � � �� _ 5.�, � � 5 _.- Y. - - .1"0� - 1!/1Y`� � � f_' �e�7�2 c.�l�'P�J Date of nspection S ic stem Inspector �n ��r�,����mJ � Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of���S� property, be advised that this report does not guarantee or certify that an existing system uill continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available�n �� information. This report must be kept on the prE�nises with the system loc�ti�n and pumping records. ����l�d� WHITE COPY/Inspectors File YELLOW COPY/Homeowner �»�- On the North Shore of Lake�Ylinnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 � 1335 S. Brown Rd. � _ � � Crystal Bay, MN 55323 473-7357 OWNER {/�:�I�IN P ���c��;r� ADDRESS ���� (.�i��l'�:iL�(r� P�A4E� PHONE PERMIT NO'S. ��-� DATES � ' j ' �%� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ❑ � Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. � � Does not meet current city standards in some respects relating to design, construction, or �ocation. Appears to be operating properly. ❑ � Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ � Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard, or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: � Septic tanks must be pumped within 48 hours. � Drainfield must be repaired or replaced within 90 days. � InspQction riser (4"diam. pipe) must be installed in each tank. � Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that tanks be pumped out ever�r thre_ e year�. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑Slope (depends on soil types,water Future Expansion ❑Soil table,and system condition) �'Adequate ❑High water table �,Low � Fair ❑Lot size ❑Medium ❑ Poor ❑Lake,wetland,or stream ❑High ❑ Inadequate �Drainage �System is causing visible surface discharge. COMMENTS: 'AlU1�S ,�SHI��,'�..� G�: Pi.J+M1'��G►�.'[� Tt� QP��=Ut'fti t ��(;r�;�'►_t��p'}�'�1 S�?�..1_�1-� Fn_a;M C'J�i �As51�'V� h �r'� PV�Y��t� G�fL���t:�! -L`�' L1fUt.S CA�ss+rvc; TE+E A,'�[� �D� (��:PAiR �2 (Z�P���:rYk°/u'��'" .J � �'7' � � �3� � , YV'�tti,%� Date of Inspection tic System Inspector This report must be kept on the premises with system location and pumping records. WH ITE COPY/ Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Mi�zr�etonkrr ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER t 11('I� n f� ��r�� ADDRESS � � MS �.'�,,,!'+�GtP- �OG� PERMIT NO.'S. `��� DATES `� - � �G'S CONTRACTO�'�Ve�me� ��=, City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regutar basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. D3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future probiems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is faiting to properiy treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfietd replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not � Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in ta�ks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: shouid be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not criticai yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibiy discharging untreated ❑ inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers 14" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Stope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table ❑ Low �Fair � Lot size �Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: G(.Y't < � ,C1,2_ � �` ,! /�� �� e!./ � - C� � c ��rr �� y � � __ Date of Inspection SepY y em Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system witl continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner nr1 tl�c Nnrtl� Shore of Lake Mizznetorzka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER //y n / • l�'✓�P� ADDRESS � PERMIT NO.'S. U �� DATES � ��� CONTRACTORS ��. City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction� I�il' � Meets or exceeds current City standards in all respects relating to design,co�struction,and location.Appears to be operating �') properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properiy; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrsding of system is required at this time. � 4 System may or may �ot meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffie. (Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. ,.�,+within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly discharging untreated �- I� Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers 14" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they shouid be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS Limiting Site Factors Potentiai for System Failure Site Capabilities for ❑ Siope (depends on soil types,water Future Expansion ❑ Soil table and system condition) �Adequate ❑ High water table � Low ❑ Fair ❑ Lot size Medium O Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: G�/ S '� � � � � I f P.Q�✓. 7 l3 9a Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner .SEPTIC .SY.STEM INVENTORY � Address: 1485 Bayridge Rd. PID: 10-117-23 34 0006 Building Type: residence #BRs/GPD 4 Systems/unit 1/1 Pennit#: 892 Date of Permit: 9/1/65 Installer: Widmer Bros. System Type: standard trench Appliances: lndry,dshw SYSTEM CONDITION Confonnity: 3 Tank Condition: 5 DF condition: 11 Failure Pot: medium � SEPTIC TANKS Material: concrete block Capacity: 600, 600 Setback to Bldg: 15 DRAINFIELD Length of Lines 275 #Lines: 5 Trench Width: 2, 3 Treatment Area: 700 Type of Filter: rock Tile Size: 4 Under Tile 6 Perc Rate: Setback DF-Bldg: 15 DF Ht above Wt: 0.5 Soil Type: loam, sandy clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 50 Report in File: n Pump Type: subm. Depth: 216 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 4/18/80 located tanks-uncover and repair baffle 2 10/1/81 1800 11/2/81 added 350 sf of DF 2 12/1/86 900 7/3/SS no surfacing 2 11/1/89 900 8/4/87 no surfacing 2 9/1/92 900 7/13/90 no surfacing-need risers 2 12/29/97 2000 7/21/92 no surfacing-need risers,pump tanks 2 4/17/94 non-confonning-repair by 12/31/96 3 � � . � � ' � � � � �• � ���g z � -�- c� � - _ _ - � _ - - — _ � � � � o � - � � � � — — . � ` ` � _ � � ` � � � � O `� � � � � M � Mt� � � q � � � � � � � � �-j (� 4—� (—� t� � � � �' o �