HomeMy WebLinkAbout07-22-2021 Septic compliance reportMit MINNESOTA POLLUTION CONTROL AGENCY Compliance inspection report form
520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS)
St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement
Instructions: Inspection results based on Minnesota Pollution Control Agency (MPGA) requirements and attached supporting
documentation — additional local requirements may also apply. Further information can be found here:
httos://www.pca,state.mn.us/sites/default/files/wa-wwists4-31a odf.
Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final
determination of compliance or noncompliance.
Property information Local trackina number
Parcel ID# or Sec/Twp/Range: Local regulatory authority: City of Orono
Property address: 410 Big Island Orono
Owner/representative: Greg O'connor Owner's phone: 8184106-5657
Brief system description: 2 - 1000 gal plastic tanks with a gravity chamber trench system
System status
System status on date (mm/dd/yyyy): 7/22/2021
® Compliant —Certificate of compliance*
(Valid for 3 years from report date unless evidence of
an imminent threat to public health or safety requiring
removal and abatement under section 145A.04,
subdivision 8 is discovered or a shorter time frame exists
in Local Ordinance.)
*Note: Compliance indicates conformance with Minn.
R. 7080.1500 as of system status date above and
does not guarantee future performance.
❑ Noncompliant — Notice of noncompliance
An imminent threat to public health and safety (ITPHS) must be
upgraded, replaced, or its use discontinued within ten months of
receipt of this notice or within a shorter period if required by
local ordinance or under section 145A.04 subdivision 8.
Systems failing to protect ground water must be upgraded,
replaced, or use discontinued within the time required by local
ordinance.
Reason(s) for noncompliance (check all applicable)
❑ Impact on public health (Compliance component #1) — Imminent threat to public health and safety
❑ Tank integrity (Compliance component #2) — Failing to protect groundwater
❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety
❑ Other Compliance Conditions (Compliance component #3) — Failing to protect groundwater
❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) — Failing to protect groundwater
❑ Soil separation (Compliance component #5) — Failing to protect groundwater
❑ Operating permittmonitoring plan requirements (Compliance component #4) — Noncompliant -local ordinance applies
Comments or recommendations
Certification
l hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction, possible
abuse of the system, inadequate maintenance, or future water usage.
By typing my name below, l certify the above staterr s to be true and correct, to the best of my knowledge, and that this information
can be used for the purpose Qf Processing this form.
Business name: SCertification number: C1659
Inspector signature: _ License number: 2502
Mrs doc en has been electronically signed) Phone: 952-873-3292
Necessary or locally required supporting documentation (must be attached)
® Soil observation logs ® Locally required forms ® Tank Integrity Assessment ❑ Operating Permit
❑ Other information (list)
https://www.pca.state.mn.us 651-296-6300
wq-wwists4-31b • 1/11/21
• 800-657-3864 Use your preferred relay service Available in alternative formats
Page 1 of 4
1. Impact on public health — Compliance component #1 of 5
criteria:
System discharges sewage to the ❑ Yes* ® No
ground surface
System discharges sewage to drain ❑ Yes* ® No
tile or surface waters.
causes sewage backup into ❑ Yes^ ®No
Any "yes" answer above indicates the system is an
imminent threat to public health and safety.
Describe verification methods and results:
Searched for surface outlet or ground discharge
Checked for back-up
Attached supporting documentation:
❑ Other.
® Not applicable
2. Tank integrity— Compliance component #2 of 5
criteria:
System consists of a seepage pit, ❑Yes• ® No _
cesspool, drywell, leaching pit,
or other pit?
Sewage tank(s) leak below their I❑ Yes* ®No
designed operating depth? I
If yes which sewage tank(s) leaks:
Any "yes" answer above indicates the system
is failing to protect groundwater.
Describe verification methods and results:
Pumped & Inspected
Attached supporting documentation:
® Pumped at time of inspection
Name of maintenance business: Sewer_ Services
License number of maintenance business: 2502
Date of maintenance: 7/22/2021
❑ Existing tank integrity assessment (Attach)
Date of maintenance
(mm/dd/yyyy): (must be within three years)
(See form instructions to ensure assessment complies with
Minn. R. 7082.0700 subp. 4 8 (1))
❑ Tank is Noncompliant (pumping not necessary - explain below)
❑ Other:
https://www.pca.state.mn,us • 651-296-6300 800-657-3864 • Use your preferred relay service Available in alternative formats
wq-ww1sts4-31b • 1/11/21 Page 2 of
3. Other compliance conditions — Compliance component #3 of 5
3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured?
❑ Yes" ® No ❑ Unknown
3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? ❑ Yes* ® No ❑ Unknown
'Yes to 3a or 3b -System is an imminent threat to public health and safety.
3c. System is non -protective of ground water for other conditions as determined by inspector?
3d. System not abandoned in accordance with Minn. R. 7080.2500?
`Yes to 3c or 3d - System is failing to protect groundwater.
Describe verification methods and results:
Inspected
Attached supporting documentation: ® Not applicable ❑
[]Yes* ® No
❑ Yes' ® No
4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 M Not applicable
Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required
Is the system required to employ a Nitrogen BMP specified in the system design? ❑ Yes ❑ No If "yes", B below is required
BMP = Best Management Practice(s) specified in the system design
If the answer to both questions is "no", this section does not need to be completed.
Compliance criteria:
a. Have the operating permit requirements been met? ❑ Yes ❑ No
It. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No
Any "no" answer indicates noncompliance.
Describe verification methods and results:
Attached supporting documentation: ❑ Operating permit (Attach) ❑
https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service • Available in alternative formats
wq-wwists4-31b • 1/11/21 Page 3 of
5. Soil separation — Compliance component #5 of 5
Date of installation 7/7/2007 ❑ Unknown
(mm/dd/yyyy)
Shoreland/Wellhead protection/Food
beverage lodging?
Compliance criteria (select one):
5a. For systems built prior to April 1, 1996,
and not located in Shoreland or Wellhead
Protection Area or not serving a food,
beverage or lodging establishment:
Drainfeld has at least a two -foot vertical
separation distance from periodically
saturated soil or bedrock.
51b. Non-performance systems built April 1,
1996, or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage, or lodging establishment:
Drainfeld has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
® Yes ❑ No Attached supporting documentation:
® Soil observation logs completed for the report (Attach)
❑ Two previous verifications of required vertical
El Yes ❑ No` separation (Attach)
❑ Not applicable (No soil treatment area)
® Yes ❑ No"
5c. "Experimental" "Other" or "Performance" ❑ Yes ❑ No*
systems built under pre -2008 Rules;
Type /V or V systems built under 2008
Rules 7080. 2350 or 7080.2400
(Advanced Inspector License required)
Drainfeld meets the designed vertical
separation distance from periodically
saturated soil or bedrock.
*Any "no" answer above indicates the system is
failing to protect groundwater.
Describe verification methods and results:
Boring
1-10"10yr 5/2 Loam
11-24" 10yr 5/3 Clay Loam
25-60" 10yr 5/6 Loam
No Redox
Indicate depths or elevations
A. Bottom of distribution media
19"
B. Periodically saturated soil bedrock
6011+
C. System separation
4111+
D. Required compliance separation*
36"
*May be reduced up to 15 percent if allowed by Local
Ordinance.
Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced,
or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the
system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by
local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the
system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict.
This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food,
beverage, and lodging establishments as defined in law.
https://www.pca.state.mn.us 651-296-6300
wq-wwists4-31b • 1/11/21
800-657-3864 Use your preferred relay service • Availablein alternative formats
Page 4 of 4
•ti�.)ota � J',w
7�b1
�-d
v
Sep 14 07 09:18a Entertainment Themes,Inc 6513061080
S -P TESTING, INC. Steven B. Schirmers • MPCA Cert.No. 627
951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566
FAX • (763) 497-5011
State License #394
1 0 • • :•:.
Greg O'Connor
410 Big Island
Orono, Henn. Co., MN
Borings completed on 8-3-07, with a hand bucket auger.
BORING
NUMBER
1- Elev.95.2 - NO MOTTLED SOIL PRESENT IN THE BORING.
10" -
16"
0 -
12"
1 opsoil dark brown loam 10YR 3/2
12" -
22"
Gray brown loam 10YR 5/2
22" -
42"
Brown clay loam 10YR 5/3
42" -
78"
Yellowish brown loam 10YR 5/6
BORING NUMBER 2- Elev.95.9 -MOTTLED SOIL AT 66" -no standing water present
in the boring.
0 -
10"
Topsoil dark brown loam 10YR 3/2
10" -
16"
Gray brown loam 10YR 512
16" -
24"
Brown clay loam 10YR 5/3
24" -
34"
Yellowish brown clay loam 10YR 5/4
34" -
66"
Yellowish brown loam 10YR 5/6
66" -
72"
Rusty yellowish brown loam 10YR 5/6 - mottles 10YR 6/8
B4RWG_NUM8ER 3- Elev.96.3 - NO MOTTLED SOIL PRESENT IN THE BORING.
0 -
8"
Topsoil dark brown loam 10YR 3/2
8" -
12"
Gray brown loam 10YR 5/2
'12" -
30"
Brown clay loam 10YR 5/3
30" -
40"
Yellowish brown clay loam 10YR 5/6
40" -
72"
Yellowish brown loam 10YR 5/6
p.5
<A \ DE TIME
CITY OF ORONO CALLED IN
INSPECTION � NOT C! TSCHEDULED
PERMIT NO. f/� OMPLETED
ADDRESS 10 461q
OWNER CONTR.
TELEPHONENO. 61a a3a 14gd l
DESCRIPTIONf7G- "
k
u FOOTING
[] MECHANICAL RI
B
y
CI FRAMING
❑ MECHANICAL FINAL
Ej
❑ INSULATION
[) WOOD BURNER/FIREPLACE
O
(_1
COMPLAINT
Z
C7 WALL BD.
[I WATER HOOK-UP
Q
iF II FINAL
❑ SEWER HOOK-UP
❑ DEMO - SITE
EJ SEPTIC MAINT.
0 DEMO - FINAL
❑ SEPTIC INSTALL.
2
❑ PLUMBING RI
0 SEPTIC FINAL
PLUMBING FINAL
w
F RRECT WORK & PROCEED
ISSUE CERTIFICATE OF OCCUPANCY
OWN ERICONTRACTOR TO MEET YOU: YES —NO
COMMENTS: On ;z.
CCw
a
J
O
`i
O %-r'1
i?1\
❑
EXCAWGRADING/FILLING
L
LAKESHORUWETLANDS
(_]
TREE REMOVAL
Ej
SITE INSPECTION
Q
PROGRESS
(_1
COMPLAINT
Li
FOLLOW-UP
L
HARD COVER REMOVAL
U
FOUNDATION/REMOVAL
O 5,2�tLSAc
s
1 CORRECT UNSAFECONDITION WITHIN HOURS. ;PHOTOTAKEN
INSPECTOR WILL RETURN
STOP ORDER POSTED. CALL INSPECTOR CITATION ISSUED
i INSPECTION REQUIRED. CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952) 249-4600
Owner/Contractor on
Inspector.
White Copy/Inspector's File Canary Copy/Site Notice
2
j
In A n,,,3
EL'
� r ►- e fi�
IT/
ORK SATISFACTORY: PROCEED
PROJECT COMPLETE
w
F RRECT WORK & PROCEED
ISSUE CERTIFICATE OF OCCUPANCY
CORRECT WORK, CALL FOR REINSPECTION
TEMPORARY
U
BEFORE COVERING
PERMANENT
1 CORRECT UNSAFECONDITION WITHIN HOURS. ;PHOTOTAKEN
INSPECTOR WILL RETURN
STOP ORDER POSTED. CALL INSPECTOR CITATION ISSUED
i INSPECTION REQUIRED. CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952) 249-4600
Owner/Contractor on
Inspector.
White Copy/Inspector's File Canary Copy/Site Notice