HomeMy WebLinkAboutPoint of Sale Inspection - Compliancy Expires 6/20/2031\`�ktsll044./
Task 54219
Date Called in 06/22/21
Date Scheduled 06/30/21 @ 12:00 im
City Of Orono
Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form
Property Address:
11307 Orono lane
PID:
10211723340007
Owner Information
Name:
Allen Greene
Mailing Address:
(if different from
Property)
�j
Lj
Phone:
336-473-4955 Email: I RAGREENE801@GMAIL.COM
Inspector I formation
Name:
Standard
Company/ Organization
�j
Lj
License number:
Roof drains and leaders Roof drains should not be connected to the sanitary
sewer but should discharge to the ground outside of a building. If the roof
Phone:
Email:
drains are connected to the sanitary sewer, disconnect them, plug any open
Inspection
System
Standard
Pass
Fail
Roof Drains
Roof drains and leaders Roof drains should not be connected to the sanitary
sewer but should discharge to the ground outside of a building. If the roof
Name:
drains are connected to the sanitary sewer, disconnect them, plug any open
connections to the sanitary sewer using a non -shrink permanent material, and
redirect the roof drains onto the ground outside the building.
Foundation
Foundation drains are underground pipes that collect storm water from
Drains
around the base of a building and into a sump basket, where it is then
pumped outside of the building. Foundation drains should not be connected
to the sanitary sewer.
Sump Pumps
Sump pumps are designed to capture surface or ground water that enters
basements or crawl spaces and pump it away from the house. The basic sump
system includes drain tile, a sump pit, a sump pump, a float or switch, and a
drain line. Sump pumps should not be connected to the sanitary sewer.
Sewer Service
Sanitary Sewer Inflow & Infiltration (1/I) Compliance Inspection Sanitary
Line
Sewer Lines. All sanitary sewer lines serving Property, from the house to the
main line, shall be in a safe and functional condition and shall be free from all
leaks, failures including but not limited to partially collapsed sections or tree
root intrusion. The sanitary sewer lines shall meet the City Code standards and
specifications. (Details on back of this sheet
Notes:
Toilet Removed
o Yes o
For Inspection:
CityReview
Inspectors Signature:
Date:
Owners Signature:
Date:
CityReview
Com liant
❑ Corrective Action Required
Certificate of Compliance Expires: -30- 0
Correctivp Action Due by:
Date:
Signature:
Name:
Lai
Service Line Inspection Details
Weather Conditions:
Approximate Depth of Service
Type and Size of Service cat
Overall Condition of Service Pie 6 ()
Please note all connections, fittings, points of concern on service line including infiltration, tree root,
cracks, inisal igned joints, etc.
This report must include a di stat copy of the televising.
Feet
Comment
Example:
0
Start for 4" cleanout in NE corner of Basement
1-10
Misaligned joint —Infiltration
0
Oq \vNp��C/ Q)v &D-D�
\\oC���
Notes: