HomeMy WebLinkAbout05-31-2021 Septic Compliance ReportSP TESTING INC. Steven B. Schirmers -951 Katydid Lane NE -St. Michael, MN 55376 Cert. No 627 - State License #f394 - Phone 763-497-3566 - Fax 763-497-5011 www.sptesting.wastewaterC@comcast.net- schirmerswastewater.com May 31, 2021 Lori Hall 3355 Graham Hill Rd. Orono, MN A Compliance inspection was completed for the existing on-site sewage treatment system located on this property for the sale of the home. The system consists of 2- 1300 gallon septic tanks, 1 -1300 gallon pump tank, a pressurized mound system with a 10' x 66' rock bed, built in 2010 for a 5 bedroom home. Soil boring #1 found mottled soil (redox features) at 2.7' into the original soil & the original soil at elev. 102.5 & the bottom of the rock bed at elev. 105.2 leaving 2.7' of sand below the rock bed & a 5.4' separation from the bottom of the rock & redox features. Soil boring #2 found mottled soil at 2.1' into the original soil & the original soil at elev. 102.6 & the bottom of the rock bed at elev. 104.9 leaving 2.3' of sand & a 4.4" separation. This system meets the required 3' separation from the bottom of the rock bed. The tanks were pumped by Kothrade Sewer, Water & Excavating, Inc. & were found to be compliant. Nothing other than gray water (laundry, showers etc.) human waste & toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended due to adding more solids & fine solids passing through into the system. Iron filters are also not recommended & should be diverted out of the system. Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower cleaners used every shower & chlorine agents may kill the bacteria you need living in the system. Additives are not recommended. Recommend to pump & clean you tanks through the manhole by a certified pumper every 2 years. Check with your pumper to set up a schedule. This certificate of compliance is no guarantee that this system will continue to function indefinitely. Steven B. Schirmers S -P TESTING, INC. Steven B. Schirmers - MPCA . Cert.No. 627 951 Katydid Lane NE - St. Michael, MN 55376 - (763)'497-3566 FAX (763) 497-5011 State License #394 wwwsptesting.wastewater@comcast.net - schirmerswastewater.com 4-1 ;?D b5. "-,-\16-6 (24a -, W MINNESOTA POLLUTION re Compliance inspection ort form CONTROL AGENCY p p p 520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS) St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement Instructions: Inspection results based on Minnesota Pollution Control Agency (MPCA) requirements and attached supporting documentation — additional local requirements may also apply. Further information can be found here: httos://www.pca.state.mn.us/sites/default/files/wq-wwists4-31a )df. Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Property information Local trackina number: Parcel ID# or Sec/Twp/Range: Local regulatory authority: tOo0 Property address: Owner/representative: �_V x} Owner's phone: 'I t,�5 ayS Mol �t Brief system description: 'A c��l s rstL'1'Wn I System status <-Or- A System status on date (mm/dd/yyyy): 5 =J q --;L ) Compliant — Certificate of compliance* (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. ❑ Noncompliant— Notice of noncompliance An imminent threat to public health and safety (iTPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or undersection 145A.04 subdivision 8. Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. Reason(s) for noncompliance (check all applicable) ❑ Impact on public health (Compliance component #1) — Imminent threat to public health and safety ❑ Tank integrity (Compliance component #2) — Failing to protect groundwater ❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance component #3) — Failing to protect groundwater ❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) — Failing to protect groundwater ❑ Soil separation (Compliance component #5) — Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance component #4) — Noncompliant - local ordinance applies Comments or recommendations Certification I hereby certify that alt the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: r -,Q " ��(iSiti�1�',/ t 1- L . Certification number: koaO Inspector signature: � -- 'f�, 1r�c - RC 1 ✓4 \ A. License number: 3 °I %+ (This document has been electronically signed) Phone: _ % (a3 - y c r2 ?, ��(1, to Necessary or locally required supporting documentation (must be attached) 64 Soil observation logs ❑ Locally required forms Tank integrity Assessment ❑ Operating Permit ® Other information (list): 41,iW https://www.pca.state.mn.us 651-296-6300 800-6S7-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 1/11/21 Page 1 of 1. Impact on public health — Compliance component #1 of 5 Compliance criteria: System discharges sewage to theI ElYes" No ground surface System discharges sewage to drainI ❑ Yes" No tile or surface waters. System causes sewage backup intoI 171Yes° F41 No dwelling or establishment. Any "yes" answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: Attached supporting documentation: ❑ Other: ❑ Not applicable i_I' (moo¢ 2. Tank integrity — Compliance component #2 of 5 `'4\,A Compliance criteria: Attached supporting documentation: System consists of a seepage pit, ❑ Yes' ❑ No ❑ Pumped at time of inspection cesspool, drywell, leaching pit, or other pit? Sewage tank(s) leak below their I ❑ Yes' ❑ No designed operating depth? which sewaoe Any "yes" answer above indicates the system is failing to protect groundwater, Describe verification methods and results: Name of maintenance business: License number of maintenance business: Date of maintenance: ❑ Existing tank integrity assessment (Attach) Date of maintenance (mm/dd/yyyy): (must be within three years) (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 8 (9)) ❑ Tank is Noncompliant (pumping not necessary — explain below) ❑ Other: https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 1/11/21 Page 2 of 4 3. Other compliance conditions — Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? []yes* W No ❑ Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? p Yes* S No ❑ Unknown `Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non -protective of ground water for other conditions as determined by inspector? ❑ Yes* ff) No 3d. System not abandoned in accordance with Minn. R. 7080.2500? ❑ Yes` B No "Yes to 3e or 3d - System is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: ❑ Not applicable ❑ 4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 W.Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required Is the system required to employ a Nitrogen BMP specified in the system design? p Yes ❑ No If "yes", B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? ❑ Yes ❑ No b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No Any "no" answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: ❑ Operating permit (Attach) ❑ https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 1/11/21 Page 3 of 4 5. Soil separation -- Compliance component #5 of 5 Date of installation ❑ Unknown (mm/dd/yyyy) Shoreland/Wellhead protectionlFood ❑ Yes Q No beverage lodging? lance criteria (select one): 5a. For systems built prior to April 1, 9996, ❑ Yes ❑ No* and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two -foot vertical separation distance from periodically saturated soil or bedrnrk 5b. Non-performance systems built April 1, ❑ Yes ❑ No* 1996, or later or for non-performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* 5c. "Experimental", "Other, or "Performance" systems built under pre -2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Advanced Inspector License required) Drainfield meets the designed vertical separation distance from periodically ❑ Yes ❑ No* *Any "no" answer above indicates the system Is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: FW Soil observation logs completed for the report (Attach) ❑ Two previous verifications of required vertical separation (Attach) ❑ Not applicable (No soil treatment area) El :Q cw UJO Sbom Indicate depths or elevations A. Bottom of distribution media 4� wyh - •3' �� B. Periodically saturated soil/bedrock s 0 C. System separation F 0 i D. Required compliance separation* *May be reduced up to 15 percent if allowed by Local Ordinance. Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or Its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. if the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined In law. https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-ww1sts4-31b • 1/11/21 Page 4 of 4 33"s &r-n-bao,7 Oi'l I 8, 6rbno ii1v 1. Impact on public health — Compliance component #1 of 5 Com liance criteria: System discharges sewage to the ❑ Yes* ❑ No ground surface System discharges sewage to drain ❑ Yes' ❑ No tile or surface waters. System causes sewage backup into ❑ Yes* ❑ No Any "yes" answer above indicates the system is an Imminent threat to public health and safety. Describe verification methods and results: ........................ _ Attached supporting documentation: ❑ Other: ❑ Not applicable 2. Tank integrity — Compliance component #2 of 5 Compliance criteria: System consists of a seepage pit, cesspool, dryweil, leaching pit, or other pit? Sewage tank(s) leak below their designed operating depth? Yes' Attached supporting documentation: ,No ❑ Pumped at time of inspection (1 Name of maintenance business:DO) El El Yes* (�rNo License number of maintenance business: V � `l Date of maintenance: ❑ Existing tank integrity assessment (Attach) Date of maintenance (mm/ddtyyyy): (must be within three years) Any "yes" answer above indicates the system (See form instructions to ensure assessment complies with is failing to protect groundwater. Minn. R. 7082.0700 subp. 4 B (1)) Describe verification methods and results: ❑ Tank Is Noncompliant (pumping not necessary—explain below) ❑ Other: tt,"VAP-ed OLA -ta,V4r 3... U00 3 tt/toil/ https,//www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service • Available in alternative formats wq-ww1sts4-31b • 1/11/21 Poge 2 of 4 SP TESTING INC. Steven B. Schirmers —951 Katydid Lane NE—St. Michael, MN 55376 Cert. No 627 — State License #394 — Phone 763-497-3566 — Fax 763-497-5011 www.sptesting.wastewater@comcast.net- schirmerswastewater.com Lori Hall 3355 Graham Hill Rd. Orono, MN Soil borings completed with a bucket auger on 5-18-21 SOIL BORING #1 - ELEV. 101.8- MOTTLED SOIL PRESENT IN THE BORING AT 2.7' INTO THE ORIGINAL SOIL. 0 - 20" Topsoil dark brown loam 2.5Y 3/2 20" - 32" Dark gray brown loam 2.5Y 4/2 32" - 36" Dark gray clay loam 2.5Y 4/3 - distinct mottles 10YR 6/8, 10YR 7/1 SOIL BORING #2 - ELEV. 101.4 - MOTTLED SOIL PRESENT IN THE BORING AT 2.1' INTO THE ORIGINAL SOIL. 0 - 12" Topsoil dark brown loam 10YR 3/2 12" - 26" Brown clay loam 10YR 4/3 26" - 30" Brown clay loam 10YR 4/3 - Distinct mottles 10YR 6/8, 10YR 7/1 SOIL BORING #3 - ELEV. 106.6 - THROUGH THE MOUND. 0 - 16" Fill soil clay loam 16" - 50" Fill soil medium sand 50" - 56" Original soil dark gray loam SOIL BORING #4 - ELEV. 106.6 - Through the mound. 0 - 12" Fill soil clay loam 12" - 48" Fill soil medium sand 48" - 54" Original soil dark brown loam