Loading...
HomeMy WebLinkAbout04-12-21 Compliance Inspection SP TESTING INC. Steven B. Schirmers -951 Katydid Lane NE-St. Michael, MN 55376 Cert. No 627 - State License#394 - Phone 763-497-3566 - Fax 763-497-5011 www.sptesting.wastewater@comcast.net- schirmerswastewater.com April 10, 2021 Daron Meyer 460 Sussex Lane Orono, MN A Compliance inspection was completed for the existing on-site sewage treatment system located on this property for the sale of the home. The system consists of 2- 1250 gallon septic tanks, 1 -1250 gallon pump tank, a pressurized mound system with a 10' x70' rock bed, built in 1995 for a 5 bedroom home. Soil boring #1 found mottled soil (redox features) at 1.7' into the original soil & the original soil at elev. 97.7 & the bottom of the rock bed at elev. 99.1 leaving 1.4' of sand below the rock bed & a 3.1' separation from the bottom of the rock & redox features. Soil boring #2 found mottled soil at 1.2' into the original soil & the original soil at elev. 96.8 & the bottom of the rock bed at elev. 99.3 leaving 2.5' of sand & a 3.7' separation. This system meets the required 3' separation from the bottom of the rock bed. The tanks were not pumped due to road restrictions. Nothing other than gray water (laundry, showers etc.) human waste & toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended due to adding more solids & fine solids passing through into the system. Iron filters are also not recommended & should be diverted out of the system. Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower cleaners used every shower & chlorine agents may kill the bacteria you need living in the system. Additives are not recommended. Recommend to pump & clean you tanks through the manhole by a certified pumper every 2 years. Check with your pumper to set up a schedule. This certificate of compliance is no guarantee that this system will continue to function indefinitely. Steven B. Schirmers SP TESTING INC. Steven B. Schirmers —951 Katydid Lane NE—St. Michael, MN 55376 Cert. No 627 — State License#394 — Phone 763-497-3566 — Fax 763-497-5011 www.sptesting.wastewater@comcast.net— schirmerswastewater.com Daron Meyer 460 Sussex Lane Orono, MN Soil borings completed with a bucket auger on 4-6-21 SOIL BORING #1 - ELEV. 100.9 - MOTTLED SOIL PRESENT IN THE BORING AT 1.7' INTO THE ORIGINAL SOIL. 0 - 14" Fill soil loam 14" - 38" Fill soil medium sand 38" - 50" Original soil very dark gray loam 2.5Y 3/1 50" - 58" Very dark gray clay loam 2.5Y 4/1 58" - 62" Dark gray clay loam 2.5Y 4/1 - distinct mottles 10YR 618 SOIL BORING #2 - ELEV. 100.6 - MOTTLED SOIL PRESENT IN THE BORING AT 1.2' INTO THE ORIGNAL SOIL. 0 - 10" Fill soil loam 10" - 46" Fill soil medium sand 46" - 60" Original soil very dark gray loam 2.5Y 3/1 60" - 66" Very dark gray loam 2.5Y 4/1 - distinct mottles 10YR 6/8 66" - 70" Olive brown clay loam 2.5Y 4/3 - Distinct mottles 10YR 6/8, 10YR 7/1 S=P TESTING, INC. Steven B. Schirmers • MPCA Cert.No. 627 951 Katydid Lane NE • St, Michael, MN 55376 • (763) 497-3566 FAX (763) 497-5011 State License #394 wwwsptesting.wastewater@comcast.net - schirmerswastewater.corn o rc`Q).-.A '\ '. jD SJ4D -X• \.-p oSsrj't.\o N. '-4, t s,,W, CA • SC „,- E ., - ✓C VI. y' --_ 6'?. sf,q,,�--— '4 -°+ -Z Z -i(-2,1 \:1 a. --\-.01:, g 11\11 / �Ot.1L \ a q9.1 5' ® 1 G n D- aT)' v g. , 5 i V; -I ® 0 „ ' / 'r>,K, 55. 101.1 r 0.4N qq.-s \ 1 // li iT 1a 11 S f,.5-_)00 94,05vy. - 1.7 v4'51>.SAL.- Ir‘0 U' • 45 ‘.- 14\/%1..11.0 I.q 1 5 4h 4 s..cc0 i 3.1 ' sro4 �-40v-S•• • SS - 100,40 4.,.cox. . )• 'v'g.Sa� tr___Y/ °I N>,So‘_. 4to•'s, 1y*k '4cr.Vau� 99,3 3.4' 5o ,%R- iia-►s . a., 3 MINNESOTA POLLUTION Com liance inspectionreport form H CONTROL AGENCY p 520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS) St.Paul,MN 55155-4194 Doc Type:Compliance and Enforcement Instructions: Inspection results based on Minnesota Pollution Control Agency(MPCA) requirements and attached supporting documentation-additional local requirements may also apply. Further information can be found here: https://www.pca.state.mn.us/sites/default/files/wq-wwists4-31 a.pdf. Inspector must submit completed form to Local Governmental Unit(LGU)and system owner within 15 days of final determination of compliance or noncompliance. Property information Local tracking number: Parcel ID#or SecfTwp/Range: Local regulatory authority: 05(;) (0• - ytouo Property address: '.,O SSS t \_'4 0 -c?P,..• Owner/representative: '::1•tycr-dr4 Owner's phone:Q c - L) - Brief system description: )?,6 or\ pS.0C',!S 2. O ' ?�� ' 114-51-f, 4-- 6s.S v System status )0' �o swt c s,�=o <-uc- E s�;� System status on date (mm/dd/yyyy): (_i • { d - I El Compliant-Certificate of compliance ❑ Noncompliant-Notice of noncompliance (Valid for 3 years from report date unless evidence of An imminent threat to public health and safety(ITPHS)must be an imminent threat to public health or safety requiring upgraded, replaced, or its use discontinued within ten months of removal and abatement under section 145A.04, receipt of this notice or within a shorter period if required by subdivision 8 is discovered or a shorter time frame exists local ordinance or under section 145A.04 subdivision 8. in Local Ordinance.) Systems failing to protect ground water must be upgraded, *Note: Compliance indicates conformance with Minn. replaced, or use discontinued within the time required by local R. 7080.1500 as of system status date above and ordinance. does not guarantee future performance. Reason(s) for noncompliance (check all applicable) ❑ Impact on public health(Compliance component#1)-imminent threat to public health and safety ❑Tank integrity(Compliance component#2)-Failing to protect groundwater ❑ Other Compliance Conditions(Compliance component#3)-Imminent threat to public health and safety ❑Other Compliance Conditions(Compliance component#3)-Failing to protect groundwater ❑ System not abandoned according to Minn. R. 7080.2500(Compliance component#3)-Failing to protect groundwater ❑ Soil separation (Compliance component#5)-Failing to protect groundwater ❑ Operating permit/monitoring plan requirements(Compliance component#4)-Noncompliant-local ordinance applies Comments or recommendations Certification i hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction,possible abuse of the system,inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: S--'P 4 -<11Jt, 1)J (� , Certification number: ba') Inspector signature: -63, �� `.� cr( J (3. St,N� nS License number: 3 (This document has been electronically signed) Phone: 7 t Lk°1-r? 3 5�tn L' Necessary or locally required supporting documentation (must be attached) Li Soil observation logs ❑ Locally required forms la Tank Integrity Assessment ❑ Operating Permit E Other information (list): ?\...1q1.4 or w�I�� https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 1/11/21 Page 1 of 4 4lu s6GS 1. Impact on public health — Compliance component #1 of 5 Com•liance criteria: Attached supporting documentation: System discharges sewage to the ❑Yes* ® No ❑ Other: ground surface ❑ Not applicable System discharges sewage to drain CI Yes' Q No tile or surface waters. System causes sewage backup into ❑Yes* in No dwelling or establishment. Any"yes"answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: �G IV'6L-1A4 D 2. Tank integrity — Compliance component #2 of 5 Corn.liance criteria: Attached supporting documentation: System consists of a seepage pit, ❑Yes* ❑No ❑ Pumped at time of inspection cesspool,drywell, leaching pit, or other .it? Name of maintenance business: Sewage tank(s) leak below their ❑Yes* ❑ No License number of maintenance business: designed operating depth? Date of maintenance: ❑ Existing tank integrity assessment(Attach) Date of maintenance If yes,which sewage tank(s) leaks: (mm/dd/yyyy): (must be within three years) Any "yes"answer above indicates the system (See form instructions to ensure assessment complies with is failing to protect groundwater. Minn. R. 7082.0700 subp. 4 B (1)) ❑Tank is Noncompliant(pumping not necessary—explain below) El Other: Describe verification methods and results: haps://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 1/11/21 Page 2 of 4 4 i.00 A 3. Other compliance conditions — Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged,cracked, etc.), or unsecured? ❑Yes' 0 No 0 Unknown 3b. Other issues(electrical hazards, etc.) to immediately and adversely impact public health or safety?0 Yes' 0 No 0 Unknown *Yes to 3a or 3b-System is an imminent threat to public health and safety. 3c. System is non-protective of ground water for other conditions as determined by inspector? ❑Yes' 0 No 3d. System not abandoned in accordance with Minn. R. 7080.2500? 0 Yes" 0 No 'Yes to 3c or 3d-System is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: ❑Not applicable ❑ 4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 ❑ Not applicable Is the system operated under an Operating Permit? ❑ Yes 0 No If"yes",A below is required Is the system required to employ a Nitrogen BMP specified in the system design? ❑Yes ❑No If"yes", B below is required BMP=Best Management Practice(s)specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? ❑ Yes ❑ No b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No Any "no"answer indicates noncompliance, Describe verification methods and results: Attached supporting documentation: ❑ Operating permit (Attach) ❑ https://www.pca.state.mn.us • 651-296.6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats Page 3 of 4 wq-wwisr54-31b • 1/11/21 5. Soil separation — Compliance component #5 of 5 Date of installation ❑ Unknown -" (mm/dd/yyyy) Shoreland/Wellhead protection/Food ❑ Yes No Attached supporting documentation: beverage lodging? El Soil observation logs completed for the report(Attach) Compliance criteria (select one): ❑Two previous verifications of required vertical 5a.For systems built prior to April 1, 1996, IC Yes separation (Attach) and not located in Shoreland or Wellhead ❑ No` ❑ Not applicable(No soil treatment area) Protection Area or not serving a food, � I beverage or lodging establishment.' M 3,'� ❑ Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock. 5b.Non-performance systems built April 1, ❑ Yes ❑ No' 1996, or later or for non-performance Indicate depths or elevations systems located in Shoreland or Wellhead ' �a, I r,,4 A. Bottom of distribution media s�� ^-, ��, , x�- „ Protection Areas or serving a food, B. Periodically saturated soil/bedrock Sha14 t n 1, beverage, or lodging establishment: C. 'i; 3.) System separation Drainfield has a three-foot vertical5 3,0 separation distance from periodically D. Required compliance separation* 9,0 saturated soil or bedrock.* *May be reduced up to 15 percent if allowed by Local Ordinance. 5c."Experimental, "Other", or "Performance" ❑Yes ❑ No* systems built under pre-2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Advanced Inspector License required) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. *Any "no"answer above indicates the system is failing to protect groundwater. Describe verification methods and results: Upgrade requirements:P9 q ements: (Minn. Stat. § 115.55)An imminent threat to public health and safely(ITPHS)must or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local oerdinance d the replaced, system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law, https://www.pca.state.rnn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 1/11/21 Page 4 of 4 Property address: / 0 G 2 LA �k71' �..J Inspector initials/Date: Z _ ( (mm/dd/yyyy) 1. Impact on Public Health —Compliance component#1 of 5 Compliance criteria: - _ Verification method(s): System discharges sewage to the ❑Yes ❑No ❑ Searched for surface outlet _ground surface. ❑Searched for seeping in yard/backup in home System discharges sewage to drain ❑Yes ❑ No ❑ Excessive ponding in soil system/D-boxes tile or surface waters. ❑ Homeowner testimony(See Comments/Explanation) System causes sewage backup into ❑Yes ❑ No ❑"Black soil'above soil dispersal system dwelling or establishment. ❑System requires"emergency"pumping Any"yes"answer above indicates the ❑ Performed dye test system is an imminent threat to public • ❑ Unable to verify(See Comments/Explanation) health and safety. ❑Other methods not listed(See Comments/Explanation) Comments/Explanation: 2. Tank Integrity— Compliance component#2 of 5 Compliance criteria: Verification method(s): System consists of a seepage pit, ❑Yes "Jo ❑ Probed tank(s)bottom cesspool,drywell, or leaching pit. // ❑ Examined construction records Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach) compliant if allowed in local ordinance. ❑Observed liquid level below operating depth Sewage tank(s)leak below their ❑Yes 1151allo Examined emptyum designed operating depth. (p ped)tanks(s) If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s) for"black soil" Any "yes"answer above indicates the 111 Unable to verify(See Comments/Explanation) system is failing to protect groundwater. ❑ Other methods not listed(See Comments/Explanation) Comments/Explanation: /.)t) li�� ) 17-2,.Lik 10,) c) i- Business Name: Kothrade Sewer,Water&Excavating, Inc. Business Address: 12059 Whitetail Ln, Hanover,MN 55341 Business Phone:763-498-8702 _ Company Representative: Larry Bursch MPCA#:0192/9199 Signature:;;-- ZeizZ „ � 3. Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to be structurally unsound. ❑Yes* 0 No ❑Unknown b. Oilier issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes* ❑No 0 Unknown "System is an imminent threat to public health and safety. Explain: c. System is non-protective of ground water for other conditions as determined by inspector. ❑Yes” ❑No *System is failing to protect groundwater. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31b • 6/4/14 Page 2 of 4