HomeMy WebLinkAboutPoint of Sale Compliance Inspection Form11
�'1A'[SII�PC
Task 52273
Date Called in 03/10/202.1
Date Scheduled 03/16/2021 @ 12:0 )pm
City Of Orono
Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form
CERTIFIFn
Property Address: 12118 Shadywood Rd EXPIRES:
PID: 11711723420016 za"
Owner Information
Name:
Geoffrey & Stephanie Martha
Mailing Address:
(if different from
Property)
�i
Phone:
847-370-7714 Email: 1 sdrnartha@gmail.con,
Inspector Information
Name:
Standard
Company/ Organization
�i
License number:
Roof drains and leaders Roof drains should not be connected to the sanitary
Phone:
Email:
sewer but should discharge to the ground outside of a building. If the roof
Inspection
System
Standard
Pass
Fail
Roof Drains
Roof drains and leaders Roof drains should not be connected to the sanitary
I Nam
sewer but should discharge to the ground outside of a building. If the roof
%
drains are connected to the sanitary sewer, disconnect them, plug any open
V
connections to the sanitary sewer using a non -shrink permanent material, and
redirect the roof drains onto the around outside the building.
Foundation
Foundation drains are underground pipes that collect storm water from
Drains
around the base of a building and into a sump basket, where it is then
pumped outside of the building. Foundation drains should not be connected
to the sanitary sewer.
Sump Pumps
Sump pumps are designed to capture surface or ground water that enters
basements or crawl spaces and pump it away from the house. The basic sump
/
system includes drain tile, a sump pit, a sump pump, a float or switch, acid a
drain line. Sump pumps should not be connected to the sanitary sewer.
Sewer Service
Sanitary Sewer Inflow & Infiltration (1/I) Compliance Inspection Sanitary
Line
Sewer Lines. All sanitary sewer lines serving Property, from the house to the
main line, shall be in a safe and functional condition and shall be free from all
/
leaks, failures including but not limited to partially collapsed sections or tree
root intrusion. The sanitary sewer lines shall meet the City Code standards and
specifications. (Details on back of this sheet)
Notes:
City Review
Inspectors Signature:
Date: /tel
Owners signature:
I Date:
City Review
IK Compliant
Corrective Action Re uired
Certificate of Compliance Expires: -11J11r1-J031
Corrective Action Due by: Le l
Date:
- s' 'al
I Si nature:
I Nam
CQos►� 5-� -�
Service Line Inspection Details
"v/
Weather Conditions:
Approximate Depth of Service
Type and Size of Service W" Q�}C� 1A�
Overall Condition of Service Pie
Please note all connections, fittings, points of concern on service line including infiltration, tree root,
cracks, misaligned joints, etc.
This report must include a digital copy of the televising._
Feet
Comment
Example:
0
Start for 4" cleanout in NE corner of Basement
1-10
Misaligned joint—Infiltration
0
o� b� �, e�
Poorv� 3ofea�z-� in
�
�
G\Q wj
l
PNIC
a`- -4.ASiv.10 4'zz -
(9V-n.e-d'l on
Notes:
4r'.Q UX'\
��,�, S�,�er 4 �a�e,l2 - tea � S o k • q��i
M