Loading...
HomeMy WebLinkAboutre: septic system CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, tRN 55323-0066 � � ON—SITE SEWA(3E TREATI�4�NT ` �► � IN3PECTION REPORT ti � ���kEsHo�'�G Owner: �D''� Address: Permit #'s: Dates:�/ /�� Contractors: p City ordinance n�nber 100 requires that each on-site sewage treatment system in Orono be inspected on a reguler basis. � The on-site sewage treatment system at the above address has been inspected and a�ears to fall into the category I checked below. (This is �an existing system [ ] new construction) S1fSTEM CONFORMiTY (1-3): 1 "CODE Sl'STEM"-A system which meets all the location, design, end construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage in�t without discharging any pollutants into ground or surface weters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treatirn3 and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet atl the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unseturated soil or sand between the distribution device and the limiting so�l characteristics. (The limitin� soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characterist�c has not been identi ied, this classification rt�ay be subject to revision.) TANK CONDITION C5-10): Tank inspection indicates: 5 P�npout not needed at this ti�. 6 Solids acc�anulation in tenks indicates they should be p�nnped out this year to help prevent future problems. 7 Solids accwiulation in tanks is at a critical level. 'fanks should be pw�ed out as soon es possible. 8 System is discharging to the surface. Tanks must be p�nped out within 48 hours to eliminate surface dischar�e. �` Inspection risers missing-tanks could not be inspected. nspection risers (4�� dia. pipe) must be installed �n each tanl a ext f tanks have not been , ut now. 10 Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids acc�nnulation). If tanks have not been p�out within the last three years, they should be p�nnped out now. DRAINFIELD CONDITION (11-14): Dr�ltnfield inspection indicates: (�.Y Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated end visibly discharging untreated effluent to the surface. Contact the City Ir�spector immediately. Repairs �st be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS (slope.setbecks.etc.): POTENTIAL FOR SYSTEM FAILURE Cdeaends on soils.uater table.etc.): COMMENTS: �. — Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the avaitable information. This report must be kept on the premises with the system locetion and p�nnping records. WHRE COPY/Inapectors File YELLOW COPY/Homeowner ' CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal eay, MN 55323-0066 a a ON-BITE 3EWA(�E TREATI�NT v�,� � INSPECTION REPORT �' G~ ��kESHo4'� Owner• �^���Addresa• � l/�,� Permit #'s: O Dates: ���� Contractore: 1 , City ordinance n�nber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treat�nt system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ ] new construction) SYSTEM CONFORMITY C1-3): 1 "CODE S1fSTEM"-A system Which meets all the location, design, and construction standards of the current City Codes, and Which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. Z "CONFORMING SYSTEM"-A system which does not meet all the lxation, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfectorily by treating and disposing of the entire current sewage input without discharging any poltutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodptain; any system which �y or may not meet all the location, design, and construction stenderds of the current City Codes and which is failir�g for any reason; and any_system with less than 3 feet of unsaturated soil or send between the dist�ibution device and the limiting so�l characteristics. (The limitin� soil characteristic �-has or [ 7 hes not been identified et this time. If the limiting soil charecterist�c has not been identified, this classificetion �y be subject to revision.> TANK CONDiTION (5-10): Tenk inspection indicates: 5 P�anpout not needed at this ti�. 6 Solids accunulation in tanks indicetes they should be p�mmed out this year to help prevent future problems. 7 Solids eccumulation in tanks is at a critical level. Tenks should be p�nped out as soon as possible. System is discharging to the surfece. Tanks must be pu�ed out within 48 hours to eliminate surface dischar$e. � Inspection risers missing-tanks could not be inspected. Inspection r' ers (4�� dia. i ) must be installed �n each tank at next p�out. If tanks have not been wi in t e as ree ye , �� 10 Inspection pipe is located directl over tank baffle (does not give eccurete measuremen � s c la ion� If tanks have not been p�out within the last three years, they should be p�nnped out now. pRAINFIELD CONDITION (11-14): D field inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, nat criticel yet. 13 Dreinfield is saturated end visibly discharging untreated effluent to the surface. Contact the City Inspector im�diately. Repairs �st be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloae.setbacks,etc.): POTENTIAL FOR STSTEM FAILURE (deaends on soils,water teble,etc.): ��}w COMMENTS: Dat of Inspection ep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does rtot guarantee or certify that an existing system w�ll continue to f�mction properly� but is merety an opim on of the adequacy of the system under current conditions based on the available inforn�t�on. This report �st be kept on the premises with the system location end p�nping records. WHITE COPY/Inspectors File YELLOW COPY/Homwwner �o� o .�� o ���-� CITY of ORONO � � ? � , :,.. �`„ �� �✓ ���a'"� �l5r Municipal Offices �, ;, G Street Address: Maitlng Address: �`�',E*ggOg'� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 . Owner: Address: 2290 Abiagdoa Way Permit #'s: B527 Dates: 6/17/86 Contractors: FTestoaka Plbg. (This is [xl an existing system [ ] new construction) . YSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level (�] has or [ ] has aot been ideatified at this time. If the saturated soil level has aot beea ideatified, this classificatioa is subject to revision.) TANK CONDITION (5-9) : 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. � Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is locate over an a e-can not measure so s accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (Duriag the last septic tank Maintenaace Pumpout the taaka [ ] were or [�j were not coafirmed to be watertight by the liceased pumpiag coatractor. If the tanks were not coafirmed to be watertight, this classi£ication is subject to revisioa.) D INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMD2ENTS: ����1 Date of Inspection S ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAR 473-0510 CITY OF ORONO �O� Municipel Offices o 0 Post Office Box 66 Crystal eay, MN 55323-0066 � � ON—SITE SEWA(�L TREA'1'l�NT INSPECTION REPORT ti ti , ��9kE8H�g'�G Owner: ���'4G(d'q- ��� � Address: �`G� ��Oi61�f��7 ��� ����JJO) Permit �'s: J � / Dates: �`-�/�O Contractors: Lf/!-5'�J'l� /-,l��I• City ordinence nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treat�nt system at the above address has been inspected ar� appears to fall into the category checked betow. (This is�an existing system [ ] new construction) SYSTEM CONFORMITT (1-3): 1 �'C�E SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any potlutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation� and which is operating satisfactorily by treating and disposing of the entire current sewage input without discherging any pollutents into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system loceted within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standerds of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic�has or [ ] has not been identified at this ti�. If the limiting soil characterist�c has not been ident' ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tenk inspection indicates: 5 Punpout not needed at this time. 6 Solids eccunuletion in tanks indicates they should Fie p�ped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be p�nped out as soon as possible. System is discharging to the surface. Tanks must be p�nnped out within 48 hours to eliminate surface dischar�e. Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each tenk et next p�a�out. If tanks have not been p�ped out within the last three years, they should be p�mped out now. 10 Inspection pipe is loceted directly over tank baffle (does rrot give accurate measurement of solids accunulation). If tanks have not been punped out within the last three years, they should be p�a�ed out now. DRAINFIELD CONDITION C11-14): ield inspection indicates: 11 rainfie[d is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Dreintield is saturated and visibty discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be co�leted within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS (slooe,setbacks.etc.): v... POTENTIAL FOR SYSTEM FAILURE tdecends on soils.water table,etc.): ��� COMMENTS: Date of Insp ction Septic System Inspector Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certtfy that an existing system will continue to function properly but is merely en op�m on of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the premises with the system location end pwiping records. WHITE COPY/Inapectors Flle YELLOW COPY/Homeowner .� o,� �r' O '4' O . � -a�����-� CITY of ORONU �,a '`�"��%�`{� "� �!�;��;���,_� ,ti,� Munlcipal Offices � ` ��-• ��-'� . t ``'�';;���°•;��`.��'�'yG Street Address: Mailing Address: .���'gs�I�g 2150 Kelley Parkway � P.O. Box 66 � Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner. ;e�� S h°tw . Address: o���v Ab�� �aa� wq`1 Cits�Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. The on-site se�s•age treatment system at the above address has been inspected and appears to fall into the categories checked belotiv. SYSTEM CONFORMIT'Y (1-3): _J___ �1 "CODE SYSTEM" An ISTS which meets a1t the location,desigi and construction standards ofthe cu�rent Orono Ntuaicipal Code. . 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locatioq design and constcuction staadards of the cutrent Orono Municipal Coda but does meet the three foot separation requirement,end which is not failing or an irnminent ihreat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A profubited ISTS;an ISTS located within a dasigiated 100-year flood plaiq any ISTS wlrich may � .or may not meet all the location,desigi,or construction staadards of the curreat Orono Municipal Code and which is failing for any reason;and aay ISTS with less than tFuee feet of unsaturated soil or saad between the distribution device and the limiting soil chazacteristics, TANK CONDITION(5-10): Tanl:inspection indicates: • � � Pumpout not n�ded at this time. i p 6 Tank must be pumped out this yeaz (city code�quires tanks to be pumped out every 3 yeazs. Tank was last pumped 1�� 5— 1�'f ), 7 Solids accumulation in tanks is at a critical a criticallaveL Tanks should ba pumped out as soon as possible. 8 SyStem is discharging to tha surface. Tanks must Ix pumped out within 48 hours to eliminate surface discharge. � Inspaction risers missing-tartks coutd not be inspzcted. Inspection risers(4"dia,pipe)must ba installzd in each tank at next pumpout If tanks ha�•a not bern pumped out within the last three yzars,thay shauld be pumped out now. 1� Inspzetion pipe is located dirzctly over taalc baffla(does not give accurata measuremertt of solids accumulation). If tanks have not been pumped out within the last three yeazs,thay should be pumped out now. DRAINFIELD CONDITION(11-14�: 11 11 Drainfield,is dry,no surfacing evident • 12 Some e�tidonce of surFacing,aot critical yet � � ' , 13 Draintirld is saturated and visibly discharging untreated effluent W tha surface. Contact the City Inspectar immediately.Repairs must be completed�rithin 90 days. 1�F Draintirld e�tent and condition unknown. co��NTs: Ne.e�� � :�spC�.��n� Q��.Q�S o� 5ea� � fia�ks �-�1 - o \ �wdc I`��� �` Date of Ins ection ' � p Septic System Iaspector �iote: In the event that this inspection report is used to satisfy the requiremenis for a mortgage or other transfer of property,6e advised that this report does not guarantee or certify that an eaisting system will coatiaue to function properly,but is mecely an opinion of the adequacy of the system under cuaent conditions based on the available infocmatioa � o� o�.._ o ���.w�T , CITY of ORONO �.� ����i���� � � � '�� ,L,�;�,����1'� ,ti,�' Municipal Ot'fices � ��'i�`,7?�Og�'yG Street Address: Mailing Address: Eg'fi 2750 Keliey Parkway P.O. Box 66 Orono, MN 55356 Crystai Bay, MN 55323-OU66 �, To Current Owner: Address: a��� ���n t��� ��� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at'the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): ,� 1�"CODE SYSTEM"An ISTS which meets all the location,design and consWctian standazds of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and wnstruction standards of the cwrent Orono Municipal Code but does meet the Uuee foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent tlueat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located withina designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standazds of the current Orono Municipal Code and a•hich is failing for any reason;and any ISTS witt►less than three feet of unsaturated soil or sand between the distributian device and the limitins soil characteristics. TANK CONDITION(5-71: Tank inspection indicates: 5 Pumpout not needed at this time. 6�Septic tanks must be pumped out this year (city code requires tanks to be pumped out once e��ery 3 years. Tank was last pumped 1\-1N—Q j ), Make sure seatic tanks are oumoed throueh manhole and not through white inspection pines T6is allows for the proper cleanmg. Keen water softner and iron filter disc6ar¢e out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out no�ti•. D INFIELD CONDITION 8-10 : � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: �C����c-��� �00� 6�•, PJrp SC��-:[.... �'��1(� �.5 �7 � - . L.0 V C v e.��ch- O�w� �C�� 5 � (r '��c� �b ��i 0.� O v� �� Cc r��,� • � � . ��•\\ ;� ('o� �O� �� Gt� Date of Inspection Matt Bolterman - Septic S}•stem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces not guarantee or certify that an exudng system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the availabie information. Telephone(952)249-4600 • Fax(952)249-4616 www ci.orono.mn.us �i'�"��-��_��''�- :,� �. � ,\'. �� . ��� � . 1 CITY of OIZ(�N�► , .:�� ..� '� � �i: , r"*}''�' . .. ~F t�ll �ti\� .�� o,Q_ ':,.�, � , Municipal Offices ��� ��� '� � ��:'�'� G `� Street Address: Mailing Address: , � ' � ��; ;„ �� ` �..9.kEs.Kp4��' �� 2750 Kelley Parkway P.O. Boz 66 �`-�:-�--:�-=�� Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Current Owner of Address �r,�%C) � ���^���'� � � `� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of tlie system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes � No If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes � No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other ' Septic Tank(s Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s)were last pumped out on ) � —I�t - c� 9 . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleanina. Comments: �. , Inspec . � Date of Inspection %�- � � . Telephone(952)249-4600 � Fax(952)249-4616 www.ci.orono.mn.us .�o,�,. O O CI'I'Y OF ORONO ,a � Muaicipal Offices r�, �, Street Address Dliailiag Addreas: '� �j�' 2750 Kelley Parkway P.O.Box 66 'Z.q �i Orono,MN 55356 Crystal Bay,MN 55323-0066 kEsBo� To: The Current Owner of Address 2290 ABINGDON WAY City Ordinance requires that onsite sewage treatrnent systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brouglit iri�o compliance by: - - December 31, 2007 December 31, 2010 Other Septic Tank(s) Pu t Needed Yes No The city recoxnmends the septic tank(s) andlor lift tank be serviced and pumped out every three (3)years. City records indicate the tank(s)were last pumped out on_ 1 1 -)�-(•o � The tank(s) should be cleaned through the ma.nhole and not through the inspection pipes, this allows for proper cleaning. Comments: a Inspec�t�d' Date of Inspection: �� �� Telephone (952) 249-4600 • Fax(952) 249-4616 www.ci.oroao.mn.us SEPTIC SYSTEM INVENTORY Site Address: 22g0 Abingdon Way PID 03-117-23-23-0010 Owner Name: Jeffrey Bakken Linda Shaw Owner Address: 2290 Abingdon Way Long Lake MN 55356- BuildinqTvpe: residence Installer: Westonka Plbg. Date of Permit: 6/17/86 Svstem Type: shallow trench BR's Designed for 6 In Musa?: No Shoreland?: SEPTIC TANKS: Material: precast concrete Capacitv: 1000, 1000 Tank Filter: DRAINFIELD: Treatment Area: 1500 Soil Boring: no DF Ht above Wt: 3 WELL DATA Setbacks -Well Tanks: 50 Well DF: 75 Report In File: Depth: 191 INSPECTION RECORDS PUMPOUT RECORDS Date ; Notes Date ; GallonsOfLiquid ; 6/3/2003 no surfacing,pump tanks,fill in holes around insp. Pipes 8/18/2011 2000� 5/21/2001 no surfacing,need inspection pipe on tanks 11/14/2001 2000� 11/15/1999 no surfacing, need risers, pump tanks 10/5/1994 2000, 10/22/1997 no surfacing-need risers,pump tanks 9/26/1991 1500 9/1/1994 no surfacing-need risers,pump tanks 7/27/1992 no surfacing-need risers 7/16/1990 no surfacing-need risers 6/19/1986 installation