HomeMy WebLinkAbout07/28/2020 Compliance Insp ReportMinnesota Pollution
Control Agency Compliance Inspection Form
520 Lafayette Road North Existing Subsurface Sewage Treatment Systems (SSTS)
St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement
Inspection results based on Minnesota Pollution Control Agency (MPCA) For local tracking purposes:
requirements and attached forms — additional local requirements may also apply.
Submit completed form to Local Unit of Government (LUG) and system owner
within 15 days
System Status
System status on date (mm/dd/yyyy): 7/28/2020
® Compliant — Certificate of Compliance
(Valid for 3 years from report date, unless shorter time
frame outlined in Local Ordinance.)
Reason(s) for noncompliance (check all applicable)
❑ Noncompliant — Notice of Noncompliance
(See Upgrade Requirements on page 3.)
❑ Impact on Public Health (Compliance Component #1) — Imminent threat to public health and safety
❑ Other Compliance Conditions (Compliance Component #3) — Imminent threat to public health and safety
❑ Tank Integrity (Compliance Component #2) — Failing to protect groundwater
❑ Other Compliance Conditions (Compliance Component #3) — Failing to protect groundwater
❑ Soil Separation (Compliance Component #4) — Failing to protect groundwater
❑ Operating permit/monitoring plan requirements (Compliance Component #5) — Noncompliant
Property Information
Parcel ID# orSec/Twp/Range:
Property address: 3485 Christine Drive, Orono Reason for inspection:
Property owner: Eric Backstrom Owner's phone: 612-222-1258
or
Owner's representative:
Local regulatory authority:
Representative phone:
Regulatory authority phone:
Brief system description: 2-1500 gallon septic tanks a 1500 gallon pump tank & a mound system
Comments or recommendations:
This compliance report is for the Mound system. Elmer Peterson recently pumped the tanks and did compliance on the tank portion
of system
Certification
I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system, inadequate maintenance, or future water usage.
Inspector name: Josh Swedlund Certification number: C1659
Business name: Sewer Sq4gAs In License number: 2502
Inspector signature: Phone number: 952-873-3292
Necessary or Lochlly Required Attachments
® Soil boring logs ® System/As-built drawing ® Forms per local ordinance
❑ Other information (list):
www.pca.state.mn.us • 651.296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwi5ts4-31 • 3116112 Page 1 of 3
Property address: 3485 Christine
1. Impact on Public Health — Compliance component #1 of 5
criteria:
System discharges sewage to the ❑ Yes ® No
ground surface.
discharges sewage to drain I ❑ Yes ® No
System causes sewage backup into ❑ Yes ® No
dwelling or establishment.
Any "yes" answer above indicates the
system is an imminent threat to public
health and safety.
Comments/Explanation:
2. Tank Integrity -Compliance component #2 of 5
criteria:
System consists of a seepage pit, ❑ Yes ❑ No
cesspool, drywell, or leaching pit.
Seepage pits meeting 7080.2550 may be
compliant if allowed in local ordinance.
Sewage tank(s) leak below their ❑ Yes ❑ No
designed operating depth.
If yes, which sewage tank(s) leaks:
Any "yes" answer above indicates the
system is failing to protect groundwater.
Com ments/Explanation:
Inspector initials/Date: JS 1 7/28/2020
(mm/dd/yyyy)
Verification method(s):
® Searched for surface outlet
® Searched for seeping in yard/backup in home
❑ Excessive ponding in soil system/D-boxes
❑ Homeowner testimony (See Comments/Explanation)
[I "Black soil" above soil dispersal system
❑ System requires "emergency" pumping
❑ Performed dye test
❑ Unable to verify (See Comments/Explanation)
❑ Other methods not listed (See CommentalExplanation)
Verification method(s):
❑ Probed tank(s) bottom
❑ Examined construction records
❑ Examined Tank Integrity Form (Attach)
❑ Observed liquid level below operating depth
❑ Examined empty (pumped) tanks(s)
❑ Probed outside tank(s) for "black soil'
❑ Unable to verify (See CommentsiExplanation)
❑ Other methods not listed (See Comments/Explanation)
3. Other Compliance Conditions —Compliance component #3 of 5
a. Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound. ❑ Yes* ® No ❑ Unknown
b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety. ❑ Yes* ® No ❑ Unknown
*System is an imminent threat to public health and safety.
Explain:
c. System is non -protective of ground water for other conditions as determined by inspector. ❑ Yes' ® No
*System is failing to protect groundwater.
Explain:
www.pca.state.mn.us • 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 3116112 Page 2 of 3
Property address: 3485 Christine Drive, Orono Inspector initials/Date: JS 1 7/28/2020
(mmlftyyyy)
4. Soil Separation — Compliance component #4 of 5
Date of installation: 7/16/1989 ❑ Unknown
(mm/ddlyyyy)
ShorelancINVellhead protection/Food beverage ❑ Yes ® No
lodging?
For systems built prior to April 1, 1996, and
not located in Shoreland or Wellhead
Protection Area or not serving a food,
beverage or lodging establishment:
Drainfield has at least a two -foot vertical
separation distance from periodically
❑ Yes ❑ No
Non-performance systems built April 1, ® Yes ❑ No
1996, or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage, or lodging establishment:
Drainfield has a three-foot,ver ical
separation distance from periodically
saturated soil or bedrock.*
"Experimental" "Other", or Performance"
systems built under pre -2008 Rules; Type IV
or V systems built under 2008 Rules (7080.
2350 or 7080.2400 (Advanced inspector
License required)
Drainfield meets the designed vertical
separation distance from periodically
saturated soil or bedrock.
❑ Yes ❑ No
Any "no" answer above indicates the system is
failing to protect groundwater.
Verification method(s):
Soil observation does not expire. Previous soil
observations by two independent parties are sufficient,
unless site conditions have been altered or local
requirements differ.
® Conducted soil observation(s) (Attach boring logs)
❑ Two previous verifications (Attach boring logs)
❑ Not applicable (Holding tank(s), no drainfield)
❑ Unable to verify (See Comments/Explanation)
❑ Other (See CommentsrExp/anation)
Comments/Explanation:
Boring:
1-18" 10yr 3/2 loam
19-26" 10yr 4/4 clay loam
No Redox
Indicate depths or elevations
A.
Bottom of distribution media
12"+
B.
Periodically saturated soil/bedrock
26"+
C.
System separation
38"+
D.
Required compliance separation*
36"
*May be reduced up to 15 percent if allowed by Local
Ordinance.
5. Operating Permit and Nitrogen BMP* — Compliance component #5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required
Is the system required to employ a Nitrogen BMP? ❑ Yes ❑ No If "yes", B below is required
BMP = Best Management Practice(s) specified in the system design
If the answer to both questions is "no", this section does not need to be completed.
a. Operating Permit number:
b. Is the
Any "no" answer indicates Noncompliance.
❑ Yes ❑ No
Upgrade Requirements (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, orits use
discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect
ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system
is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or
its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law.
www.pca.state.mn.us 651-296-6300 * 800-657-3864 TTY 651-282-5332 or 800-657-3864 . Available in alternative formats
wq-wwists4-31 • 3116112 Page 3 of 3
T
z
09/16/2110 J0:16 1634988290 RUSTYS PERC TESTING
Logs of Soil Borings
License 4810
Location or Project: 3485 Christine Drive
Bonngs made by: Rusty Olson's Soil and Perc testing 2/15/201[
classification System: AASHO ; USDS USOSSCS_X_; Unied_; Other,
Auger used (check two): Hand _X_, or Power , Flight, Bucket or Probe _X_
Bench mark is top of basement concrete slab. Elv.-100.00 Assumed
Number _1_ Surface elevation _100.0_
)ark brown loam 10yr3/1
Rusty brown loam to clay loam 10yr4/2
Rusty brown clay loam 10yr513
-around at sail boring # 1 Elv.-100.00 assumed
if soil under the rockbed Elv.- 99.5
1 of rock bed Elv.-100.5
is1.0 feet of sand under the rockbed
PAGE 06
Mottled Soil at _ 3.3 feet
H2O present at _X_