Loading...
HomeMy WebLinkAboutCompliance Insp_1290 French Creek Dr_Passed 8-12-2024910 Territorial Road, Rogers, Minnesota 55374 • 763-428.4489 info@endeseptic.com • www.endeseptic.com Project: 1290 French Creek Dr Wayzata, MN 55391 A septic compliance inspection was completed, and the system is Compliant according to the MPCA codes for Chapter 7O8o and local codes for the City of Wayzata in Hennepin County. The system the following attributes: Date Home Built: 1987 Bedrooms: 5 Date Septic Built: 1987 Septic Tanks: 2 -1000 -gallon septic tanks, manhole cover to grade, inlet and outlet baffles in place Pump Tank: l000 -gallon tank, manhole cover to grade. 1/2 hp pump, on/off float and alarm float in working condition during inspection. Soil Treatment: Pump fed trenches. 2 trenches located each about 75-80 feet in length. Ende Septic Service, LLC, has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. State. Sec. 155.55 (2010). The compliance inspection covers only the criteria required by Minn. Stat. Sec. 155.55, Subd. 5a (2010 and Minn. R. 7080.1500 (2011). A Compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Ende Septic Service, LLC, disclaims any use of the compliance inspection beyond determining SSTS compliance pursuant to Minn. Stat. Sec. 155.55 (2010). 4/ C C a io �a Minnesota Pollution Compliance Inspection Form Control Agency = Existing Subsurface Sewage Treatment Systems (SETS) 520 Lafayette Road North SL Paul, MN 55155-4194 Doc Type: Compliance and Enforcement Inspection results based on Minnesota Pollution Control Agency (MPCA) For local tracking purposes: requirements and attached forms — additional local requirements may also apply. Submit completed form to Local Unit of Government (LUG) and system owner within 15 days _. System Status System status on date (mmldd/yyyy) 8/12/2020 ® Compliant — Certificate of Compliance ❑ Noncompliant — Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.) frame outlined in Local Ordinance.) Reason(s) for noncompliance (check all applicable) ❑ Impact on Public Health (Compliance Component #1) — Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance Component #3) — Imminent threat to public health and safety ❑ Tank Integrity (Compliance Component #2) — Failing to protect groundwater ❑ Other Compliance Conditions (Compliance Component #3) — Failing to protect groundwater ❑ Soil Separation (Compliance Component #4) — Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance Component #5) — Noncompliant Property Information Parcel ID# or Sec/Twp/Range: 1011723320011 Property address: 1290 French Creek Dr Orono, MN Reason for inspection: Property Transfer Property owner: Jason Cuthbertson Owner's phone: or Owners representative: Jen Kyllonen Representative phone: 612-839-1871 Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600 2-1000 gallon septic tanks and a 1000 gallon pump tank. Effluent pumped to an elevated trench Brief system description: systen Comments or recommendations: Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. Inspector name: Tristan Ende _ Certification number: C9206 Business name: Ende Sqptic Service Inspector signature: �L„i i Necessary or Locally Required Attachments ® Soil boring logs ® System/As-built drawing ❑ Other information (list): License number: L2654 Phone number: 763428-4489 ❑ Forms per local ordinance www.pca.state.mn.us 651-296-6300 800-657-3864 TTY 651-282-5332 or 800.657-3864 Available in alternative formats wq-wwists4-31b • 614114 Page 1 of 3 Property address: 1290 French Creek Dr Orono, MN 1 Impact on Public Health — Compliance component #1 of 5 Compliance criteria: System discharges sewage to the ❑ Yes ® No round surface. System discharges sewage to drain ❑ Yes ® No tile or surface waters. System causes sewage backup into ❑ Yes ® No dwelling or establishment. Any "yes" answer above indicates the system is an imminent threat to public health and safety. Comments/Explanation: 2. Tank Integrity — Compliance component #2 of 5 criteria: System consists of a seepage pit, cesspool, drywell, or leaching pit. Seepage pits meeting 7080.2550 may be compliant if allowed in local ordinance. _ ❑ Yes ® No Sewage tank(s) leak below their ❑ Yes ® No designed operating depth. If yes, which sewage tank(s) leaks: Any "yes" answer above indicates the system is failing to protect groundwater. Com ments/Explanation: Tanks pumped by Ende Septic Service on 08/07/2020 Inspector initials/Date 8/12/2020 (mm/ddtyyyy) Verification method(s): ❑ Searched for surface outlet ® Searched for seeping in yard/backup in home ❑ Excessive ponding in soil system/D-boxes ❑ Homeowner testimony (See Comments/Explanation) ❑ "Black soil" above soil dispersal system ❑ System requires "emergency" pumping ❑ Performed dye test ❑ Unable to verify (See Comments/Explanation) ❑ Other methods not listed (See Comments/Explanation) Verification method(s): ❑ Probed tank(s) bottom ❑ Examined construction records ❑ Examined Tank Integrity Form (Attach) ❑ Observed liquid level below operating depth ® Examined empty (pumped) tanks(s) ❑ Probed outside tank(s) for "black soil" ❑ Unable to verify (See Comments/Explanation) ❑ Other methods not listed (See Comments/Explanation) 3. Other Compliance Conditions — Compliance component #3 of 5 a. Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound. ❑ Yes* ® No ❑ Unknown b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety. ❑ Yes* ® No ❑ Unknown *System is an imminent threat to public health and safety. Explain: c. System is non -protective of ground water for other conditions as determined by inspector. ❑ Yes' ® No *System is failing to protect groundwater. Explain: www.pca.state.mn.us • 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-ww4sts4-31b • 614114 Page 2 of 3 Property address: 1290 French Creek Dr Orono, MN Inspector initials/Date:A�l 8/122020 (mm/ddjM) 4. Soil Separation — Compliance component #4 of 5 Date of installation: 1987 (mm/dd/yyyy) Shoreland/wellhead protectioNFood beverage lodging? criteria: For systems built prior to April 1, 1996, and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment. Drainfield has at least a two -foot vertical separation distance from periodically saturated soil or bedrock. ❑ Unknown Verification method(s): Soil observation does not expire. Previous soil ❑ Yes ® No observations by two independent parties are sufficient, unless site conditions have been altered or local requirements differ. ® Yes ❑ No ® Conducted soil observation(s) (Attach boring logs) ❑ Two previous verifications (Attach boring logs) ❑ Not applicable (Holding tank(s), no drainfield) ❑ Unable to verify (See Comments/Explanation) Non-performance systems built April 1, ❑ Yes ❑ No 1996, or later or for non-performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* "Experimental", "Other", or "Performance" systems built under pre -2008 Rules, Type IV or V systems built under 2008 Rules (7080. 2350 or 7080.2400 (Advanced Inspector License required) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. ❑ Yes ❑ No Any "no" answer above indicates the system Is failing to protect groundwater. ❑ Other (See Comments/Explanation) Com ments/Explanation: Indicate depths or elevations A. Bottom of distribution media 30" B. Periodically saturated soil(bedrock 60" C. System separation 30" D. Required compliance separation* 24" *May be reduced up to 15 percent if allowed by Local Ordinance. 5. Operating Permit and Nitrogen BMP* — Compliance component #5 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required Is the system required to employ a Nitrogen BMP? ❑ Yes ❑ No If "yes", B below is required BMP = Best Management Practices) specified in the system design If the answer to both questions is "no", this section does not need to be completed. ;ompliance criteria a. Operating Permit number. b- Is the BMP in olace and Any "no" answer indicates Noncompliance. ❑ Yes ❑ No Yes n No Upgrade Requirements (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. H an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law. www.pca.state.mn.us • 651-296.6300 800-657.3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-ww1sts4-31b • 614114 page 3 of 3 C) 00 w 1Z C o' 40 • u 2�3 u i x N o U � v cC 3 N a U 00 U) s N O O U -p U C U C v v v u b L N o o u Ca u •o v v v C N O N O N 0 a� v v v u b L o o o A U U b at V C C — 0 N OO (O OO � U v On c N W c rT� u u v v v C N O N O N 0 a� v v v u b L o o o V O O O C C — 0 N OO (O OO f9 OO U v On c N W c N 00 c u 4040 L v v v N N N CQ W O O O Y! O a C C C t3 > co On 00 n0 w s a v v L 0 to 00 W o U 4 m m > o K o O o O � Y CE > ti 4' '6 k N O 0 0 O- 0 N O_ O C a C O .0 " N v� v � Q � ^•' 7 I �O Q o, w L � o � y U M t7 O > > v Of 0 Q � 1 C C O m 03 a3 0 0 0 o r hN O o Q u C y v v v v, Ci N O N O N 0 0 U u b L v O v O v O O O O C C C y CQ N OO (O OO f9 OO v On c N W c N 00 c 4040 L CQ W Y! O a t3 > w L 0 � Ln o U 4 m m > o K o O o O } 0 O ti H 0 0 0 0 N r •� C O .0 M v� v � Q � ^•' 7 I �O Q Pump Fed Trenches sbt ��sb2 Supply Line garage 21000 Qatlon Septic Tank - .0. 1000 Gallon house 11^ 'r `ch Creek Dr Pump Tanki ,Google Earth