HomeMy WebLinkAboutNexseal Info Zi3 a d VG9C7 let
NexsealTM 2.0 LE
piP I
Spray Foam Insulation
Division 7: Thermal & Moisture Protection
polyurethane systems
Product Description: ASTM E-84:
NexsealTM 2.0 LE spray foam insulation is a spray-applied, two NexsealTM 2.0 LE spray foam is an ASTM E-84 (NFPA 255,
component, closed cell polyurethane foam insulation system. UL723)class 1 (Class A)spray foam insulation.
The product is formed by the reaction of proprietary resin Flame Spread Index<25
blend and polymeric methylene diphenyl diisocyanate. The Smoke Developed Index<450
resin blend is comprised of Polyols, additives, fire retardants Thickness 4 inches
and low global warming potential blowing agents. The These numerical flame spread values are not a true reflection
proprietary system is specially formulated to reduce reaction on how this or any material will perform in actual fire
exotherm during application and provide improved
conditions.
dimensional stability.
The spray applied nature of NexsealTM 2.0 LE spray foam allows Thermal Barriers:
the material to flow into voids and seal cracks, expanding to NexsealTM 2.0 LE spray foam must be separated from the
form a monolithic structure with high R-value (resistance to interior of the building (occupied space) by an approved 15
heat flow). NexsealTM 2.0 LE spray foam can form various minute thermal barrier such as%" inch gypsum board or other
control layers for buildings and structures: insulation, air equivalent material. Consult local building codes for
barrier, moisture retarder and weather barrier. requirements and restrictions.
Product Uses: Chemical Attributes:
Cold Storage Walls Attics Component Viscosity(25°C) Density
Crawlspaces Tanks Pipe Insulation Isocyante 200 cps 10.3 Ibs/gal
Exterior Applications Ducts Foundations Resin 700 cps 10.3 Ibs/gaI
Concrete slab
Typical Physical Attributes:
Property' Test Method Value
Apparent Density ASTM D-1622 2 lbs/ft3(nominal)
R-value(aged) ASTM C-518 7.0 R/in
Compressive Strength ASTM D-1621 nom. 25 lbs/in2
Tensile Strength ASTM D-1623 nom.50 lbs/in2
Closed Cell Content ASTM D-6226 >90%(vol.)
Water Absorption ASTM D-2842 <2%
Water Vapor Permeance ASTM E-96 <2 perm-inches
Fungi Resistance ASTM C-1338 No growth
Flame Spread Index ASTM E-84 <25
Smoke Developed Index ASTM E-84 <450
Dimensional Stability,-20°F ASTM D-2126 <5%Change
Dimensional Stability,+158°F ASTM D-2126 <10%Change
Dimensional Stability,+158°F&100%RH ASTM D-2126 <10%Change
Ignition Barrier ICC ES AC377 Appendix X Pass no coating
Thermal Barrier NFPA 286 Pass DC315 89 ft2/gal
Global Warming Potential n/a 1
t These values are typical. However values will vary and should not be considered part of the product specifications.
It is imperative that the trained applicator read and understand this technical datasheet and SDS to process the
material correctly and understand environmental and equipment limitations.
�g4ROtlh
F :i International Fireproof Technology, Inc. Paint To Protect TM
/ 17528 Von Karman Ave.Irvine,CA 92614
N-
949-975-8588
DC 315 applied over Spray Polyurethane Foam (SPF), if a coating has not passed a full scale test on a manufacturer's foam it
is an Alternative Barrier System in "Section 2603.9 cannot be used on that foam;there are no exceptions in the IBC Code!
• Special Approval" as a thermal barrier. To be approved Building Code Fire Performance Requirements for SPF:
as an Alternative Barrier System, DC 315 is applied over The International Building Code (IBC) mandates that SPF be separated
a manufacturer's SPF and tested to the criteria of an from the interior of the building by a 15 minute thermal barrier, or other
Dot NFPA 286, UL 1715, UL 1040, or FM 4880 for duration approved covering. DC 315 passed certified NFPA 286 and UL 1715 test
of 15 minutes by an accredited fire testing facility. over a variety of open and closed cell spray applied urethane foams that
Products that pass an ignition barrier tested under AC were conducted by ISA certified testing facilities. All tests performed
377 Appendix X are not appropriate alternative comply with the requirements of 2006 IBC Section 803.2.1 & 2009 IBC
thermal barriers and cannot be used. Depending on your particular Section 803.1.2,and Section 2603.9;2012 IBC Section 803.1.2 and Section
application, either ignition or thermal barriers are required by the 2603.10 under "Special Approvals for Thermal Barriers over Foam
International Building Code (IBC). Plastics". DC315 is WHI marked and certified via 3`d party inspection for
Properties Value quality assurance and consistency.
Finish Flat Alternative 15 min Thermal Barrier Assemblies(e.g.Exposed SPF or SPF
with a Thermal Barrier Protective Covering)
Color Ice Grey The assembly must remain in place for 15 minutes during specified large-
V.O.C. 47g/L scale fire tests,such as NFPA 286,UL 1715,UL 1040,or FM 4880.
Solids By Volume 67% Alternative Ignition Barrier Assemblies DC 315 meets the requirements
for ignition barrier per AC 377,Appendix X
Specific Gravity 1.30+/-0.05 g/cc
Application Equipment
Drying Time @77°F &50% R.H. To touch 1—2 hours, to DC 315 can be applied by brush,roller or airless sprayer.
recoat if required 2 to 4 hours For maximum yield and coverage spray application is recommended.
Flash Point None Sprayers:
Reducing or Cleaning Water Pump: (Graco)UltraMax 695 or equivalent
PSI: 3000
Shelf Life 1 year from date of manufacture in unopened
containers and stored at 1 0°C to 27°C(50°F to GPM: 1.00
80°F) Tip: 517-521 or equivalent.
5 Gal.Container Weight 58 lbs. Filter: 30 mesh, removal of filter is recommend from gun and
machine
Advantages of Using DC315 SPF Hose: 3/8"diameter airless spray line for the first 100'from pump
and%"x 3'whip
■ DC 315 is the only 3`d party inspected fire protective coating for SPF Pump: (Grace)TexSpray Mark 5 or equivalent
• Marked and Listed by Warnock Hersey Intertek W/N 20947 PSI: 3300
• Single coat coverage reducing labor and material costs equaling GPM: 1.35
higher profits
Industry leading spread rate Tip: 517 523 or equivalent.
• Passed CAL 1350-safe for use in schools and high occupancy Filter: 30 mesh, removal of filter is recommend from gun and
• buildings machine
• Passed strict EPA—V.O.C.and AQMD air emission requirements(for Hose: 3/8"diameter airless spray line for the first 100'from pump
all 50 states) and 14"x 3'whip
■ Approved for Incidental Food Contact complies with NSF/ANSI-51
requirements of USDA Pump: (Grace)GMAX 7900 or equivalent
• Easily applied with a sprayer,roller,or brush with no complicated PSI: 3300
mixing GPM: 2.2
• 1 year shelf life Tip: 517-529 or equivalent.
■ Fast and easy clean-up,with no waste and fast turnaround time Filter: 30 mesh,removal of filter is recommend from gun and
• Compatible with any paintable construction material machine
• Meets Life Safety Code 101 Hose: 3/8"diameter airless spray line for the first 100' 300' from
• Meets LEED's point requirements pump and%"x 3'whip
• No formaldehyde
Pump: (Graco)GH 833 or equivalent
DC 315 is the most tested and approved product in the world for use as PSI: 4000
an,"Alternative Thermal Barrier Coating System"over Spray GPM: 4.0
Polyurethane Foam(SPF).
Tip: 517-529 or equivalent.
Filter: 30 mesh, removal of filter is recommend from gun and
Visit us at our website www.painttoprotect.com to obtain a current matrix machine
of all the manufacturer's foams DC 315 has been tested and approved as Hose: 3/8"diameter airless spray line for the first 100'-300' from
Thermal or Ignition barriers in compliance with current IBC codes. pump and'/<"x3'whip
•
Prior to Applying DC 315 to Ensure Proper Adhesion: Surfaces must General Safety,Toxicity,Health Data
be clean, dry and free of all foreign matter.Adhesion of a coating to SPF Material Safety Data Sheets are available on this coating material. Any
requires the foam surface to have a slight profile or texture similar to an individual who may come in contact with these products should read and
orange peel. Smooth or glossy foam surfaces must be flash coated with a understand the M.S.D.S. In case of emergency contact CHEMTREC
light 3 -4 mils Wet Film Thickness(WFT) of DC 315 and allowed to dry EMERGENCY NUMBER at 800-424-9300.
before applying the full application. Flash coating is a quick burst of a
primer or DC 315,via airless sprayer over an area needing treatment. We WARNING:Do not allow product to freeze.Store above 10°C(50°F)at all
also recommend flash coating around all pipes and air ducts. times.
Product Application WARNING: Avoid eye contact with the liquid or spray mist. Applicators
In order to validate warranty and confirm the installation complies with should wear protective clothes,gloves and use protective cream on face,
IFTI's best practices installer must obtain and read all current installation hands and other exposed areas.
documents.Installation documents include Application Guide, EYE PROTECTION:
Ventilation Guide and Job Work Report. Safety glasses,goggles,or a face shield are recommended.
These documents can be downloaded at www.painttoprotect.com or by
calling IFTI at 949.975.8588. "Job Work Records are an excellent way to SKIN PROTECTION:
track your installations and confirm compliance to your Building Official or Chemical resistant gloves are recommended, cover as much of the
Authority Having Jurisdiction. In the event of a concern on a job the exposed skin area as possible with appropriate clothing.
installer is able to provide documented proof of the installation, for this
reason IFTI recommends using these forms for all thermal barrier jobs." RESPIRATORY PROTECTION is MANDATORY!
Respiratory protective equipment,impervious foot wear and protective
Material Preparation clothing are required at all times during spray application.
DC31S must be thoroughly mixed prior to application. Failure to do so will
compromise the materials performance and may create issues with INGESTION:Do not take internally.
equipment used for the application of the product. Mechanical stirring
with a high speed drill and a paddle appropriate for the container size is Consider the application and environmental concentrations in deciding if
recommended. Material should be stirred from the bottom up making additional protective measures are necessary.
sure the bottom and sides are scraped with a paint stick during the mixing
process to ensure all materials are completely mixed prior to the Limited Warranty
application. Material should be mixed to a creamy consistency with no This product will perform as tested if applied and maintained according to
lumps. Thinning is not usually needed, but if the material has been our directions, instructions and techniques. If this product is found to be
exposed to prolonged periods of high temperatures during storage, defective upon inspection by its representative, the seller will, at its
evaporation of the water based material may have taken place.Typically option,either furnish an equivalent amount of new product or refund the
the liquid level should be about 3 inches from the top of the 5 gallon pail. purchase price to the original purchaser of this product.Seller will not be
If the level of material is lower,water may be added during the mixing to liable for any representations made by any retail seller or applicator of the
address this issue. product. THIS WARRANTY EXCLUDES (1) LABOR OR COST OF LABOR FOR
THE APPLICATION OR REMOVAL OF THIS PRODUCT OR ANY OTHER
Temperature and Humidity PRODUCT,THE REPAIR OR REPLACEMENT OF ANY SUBSTRATE TO WHICH
Ensure temperature and humidity are within specified limits for THE PRODUCT IS APPLIED OR THE APPLICATION OF REPLACEMENT
application. Failure to monitor and compensate for increased humidity PRODUCT, (2) ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. OTHER
may lead to blistering and/or delamination and will void warranty.Obtain LIMITATIONS APPLY.For the complete terms of the limited warranty,go to
a ventilation guide prior to commencing installation. Ideal conditions are www.painttoprotect.com. Some states/provinces do not allow the
16°C-32°C(62°F to 90°F)and a maximum of 65%Relative Humidity. exclusion or limitation of incidental or consequential damages, so the
above limitations may not apply to you.To make a warranty claim,write
Ventilation to Technical Service, International Fireproof Technology, Inc., 17528 Von
When spraying in enclosed spaces,regardless of size,adequate ventilation Karman Avenue, Irvine, CA 92614 or email Customer Service at
is required to remove excess moisture from the application area.The use ptp@painttoprotectcom
of fans may be required in some cases to ensure a minimum of 0.3 air
changes per hour. Prior to starting a job please be sure to download a
complete current ventilation guide at www.painttoprotect.com
Rev:12/18/2014 5:17 PM
Job Work Record Should be Filled Out For Each and Every Job.Completed Work Records Must be Submitted To workrecords@painttoprotect.com Within 10
Days of Job Completion.
..
a• ", :, International Fireproof Technology. InaPaint to Protect TMbo-
i.,.. .2
• �`% DC315 Certified Approved Thermal - Ignition Barrier Over
Polyurethane Spray Foam
�,.,. All model Building Codes mandate that polyurethane spray foam be separated from the interior of the building by a 15 minute
thermal barrier or other approved covering. DC315 has passed certified ULC 5101, NFPA 286 and UL 1715 testing, at
I recognized 3rd party testing facilities, over a variety of open and closed cell spray polyurethane foams. It complies with all
the requirements of 2006 IBC Section 803.2.1; 2009 IBC Section 803.1.2 and Section 2603.9; 2012 IBC Section 803.1.2 and
4',= Section 2603.10 & & 2015 IBC Section 803.2.1 and IBC Section 2603.9 under "Special Approvals for Thermal Barriers
over Foam Plastics". DC315 also meets the requirement as an Ignition Barrier per AC 377, Appendix X at an incredible
spread rate of 400 sq.ft.pergallon.
DC315 Tested Solutions for the Spray Polyurethane Foam 0 L ti
• More full scale Thermal and Ignition Barrier tests than any other product in the world L • , j
• DC 315-3rd, party inspected for Quality Control:Warnock Hersey Intertek W/N 20947 r� T
• Tested useful life,fire resistant property is not compromised after 50 years 0
• Top coat for color,weather&moisture protection,tested,via NFPA 286 full scale
testing ■ a as. •
• ANSI 51 testing for incidental food contact
• Passed CAL 1350-qualify DC 315 as a low-emitting material in the Collaborative for
High Performance Schools rating system(CHPS Designed&CHPS Verified)
• Passed strict EPA—V.O.C.and AQMD air emission requirements(for all 50 states)
• 3rd Party tested"Single Coat Coverage"up to 24 Mils WFT,on ceilings and walls,
reducing labor costs equaling higher profits
• Meets Life Safety Code 101
• Meets LEED's point requirements
• No formaldehyde
Characteristics
• Finish: Flat
• Color: Ice Gray,White and Dark Grey are special order
• V.O.C.: (47 g/l)
• Volume Solids: 67%
• Drying Time @ 77°F&50%RH To touch 1-2 hours to recoat 2
to4hours
• Type of Cure: Coalescence
• Flash Point: None
• Reducer/Cleaner: Water
-
• Shelf Life: 1 year(unopened)
• Packaging: 5&55 gallon containers
• Shipping weight: 5 gallon pail-58 lbs.55 gallon drum-640 lbs.
• Application: Brush,roller,conventional and 1` ,
airless spray
Testing and Certification
• ASTM E84-Flame Spread 0 Smoke 10
• CAN/ULC 5102 FSR 23 SDC 145-(tested as a system over SPF)
• UL 1715,NFPA 286-over 140 test passed
• CAN/ULC S 101-25 minutes as a system over SPF
• WH Listed-Spec ID 32890
International Fireproof Technology,Inc.
17528 Von Karman Ave.Irvine,CA 92614
C IiirD US
Office:949-975-8588
Web Site www.Painttoprotect.com
Email:ptp@painttoprotect.com 8/21/15
Choice Foam Insulation Licit BC723380
3208 Oakland Ave.
Minneapolis, MN 55407 `
(651)808-1429
choicefoaminsulation@gmail.com
www.choicefoaminsulation.com CHOICE FOAM
INSULATION
INVOICE
BILL TO INVOICE# 2611
Marty DATE 04/05/2018
Premier General Contracting DUE DATE 05/05/2018
17671 76th Ave N TERMS Net 30
Maple Grove 55311
ADDRESS
238 Shadywood Rd Orono
ACTIVITY AMOUNT
Insulation 3,000.00
Install 2 inches of 21b closed cell foam onto
1500sgft ceiling.
Fire Barrier 2,030.00
Install DC 315 over the 2 inches of spray foam
to 12mils thickness to give it the proper fire
break.
........................................ ...
BALANCE DUE $5,030_00