Loading...
HomeMy WebLinkAboutSeptic System Inspections CITY OF ORONO Municipal Offices O Ate\ Post Office Box 66 '_ to_ Crystal Bay, MN 55323-0066 6; 1 ON-SITE SEWAGE TREATMENT � Al . Al7: A INSPECTION REPORT '4kESHfiA Owner: Qn&1T Cf2.S NX...54-kClenSAddress: .c !Y�✓YY.fc!/1e? Rd Al Permit #'s: aR317 RPp,ot-Dates: %/310-z5i Contractors: SiA19y^,- City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is)41,an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): p Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): / Dr field inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): .Midilihe COMMENTS: : i0 dL �- Lam! ci/i Date of Inspection S=. is System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner At CITY OF ORONO : O Municipal Offices O O Post Office Box 66 = t 0. Crystal Bay, MN 55323-00661' ON—SITE SEWAGE TREATMENT 1 41) ,• INSPECTION REPORT Owner: Fr,. RLrt c icie 7c Address: K2S Fern/I:ILE/1th_ Permit 0's:a317 pro- Dates: /V ,3U-6 ) Contractors: ,c)///1012)1 City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is X an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): z 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input 1 without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil g wand between the distribution device and the limiting soil characteristics. E� �/ E -3)- 7 YS' (The limiting soil characteristic 4 has or [ ] has not been identifie�ati is time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): 7 Tank inspection indicates: 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. ���$$$ System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): ) Dafield inspection indicates: Vygjj Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): jA/af-Tie POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): )10)_, OMMEN S: pl -Taco . C /4.: ► (6._' JIB l ikk tti ,f) 4�Y 1 �, AAA FeY'�(+' Irk 'Q •. St.S �Ye+n CCnr� . rA % Ji s .!.,f//ii' Date of Inspection Septi System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner #0,04. 0 0 :0r �, CITY of ORONO \, � , titi Municipal Offices . �,,� , G Street Address: Mailing Address: t` f gg0* 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: r�1i1cC c , Ce/'.�c" Address:625 Ferndale Rd. N. Permit #'s:2317 Dates:10/30/69 Contractors:Sullivan (This is [ ] an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [ has or [ ] has not been identified at this time. If the saturated soil level has t een identified, this classification is subject to revision.) TANK CONDITION (5-9) : 6 �5 Pumpout not needed at this time C.6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were orwere not confirmed to be watertight by the licensed pumping contractor. If thetanks were not confirmed to be watertight, this classification is subject to revision. ) DRAINFIELD CONDITION (11-14) : 12 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : high COMMENTS: Repairs must be completed by 8/31/96. 1.L -,i1Cirige Date of Inspection tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 4 O N. �O O i; CITY of ORONO , ,.A \, ,� �,` titi Municipal Offices ,�„ ..I T `NG Street Address: Mailing Address: `�$ Hp�' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: 1--ra/ e. 0)c &s-i-r(-4enc-- Address: 625 Ferndale Rd. N. Permit #'s: 2317 Dates: 10/30/69 Contractors: Sullivan (This is 11ei an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3).: 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [X] or is not [ ] identified under this septic system. If the saturated soil level is not i entified, this classification is subject to revision.) TANK CONDITION (5-9) : 7 5 Pumpout not needed at this time. 0Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is (`,,] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) 6INFIELD CONDITION (11-14) : 11 1] Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : failing COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0.5 feet and the system is non-compliant. The septic tank is also discharging to the surface and the system must be repaired or replaced by 10/15/98. 7_,:2_9e 11A- i 1--inee Date of Inspection ept'c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 � o.4 .,x„ . -,.-.,..r ,,,,,-14*,,r,,,,,- , CITY of ORONO ',.y=. i ` �tti Municipal Offices .49 v;r,,f! I �4�G Street Address: Mailing Address: jCEggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 CrystalC� Bay, MN 55323-0066 To Current Owner: Address: 6c 5 F-. (nj k) / c,1 t I+j City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. 6STEM CONFORMITY (1-3): I "CODE SYSTEM" An ISIS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 'NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason; and any ISIS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): C Tank inspection indicates: 6 Pump out not needed at this time. Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks arejumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DDAINFIELD CONDITION(8-10): 7, 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing, not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: V c\:,t:11 lo c\(5 C>\(..._ U n i Sz t h-c_ - -,\10 5 V Nor-sr,(*-- .)..1,0 LA - *--.)..1,LLA . 4.,, ht,iv.,.._ Date of Inspection Matt Bolterman— Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616