Loading...
HomeMy WebLinkAbouton-site sewage treatment system On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENTCITY INSPECTION REPORT i OFPOST OFFICE BOX 66 O.ONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER i-�R yOUNGk� ��� ADDRESS 11$0 WYNOMC-AV PERMIT NO.'S. -1098' DATES S"VS "83 CONTRACTORS LJESTONKA City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is A an existing system ❑ new construction) ® 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. 04 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) TakJJJinspection indicates: 11Inspection pipe is located directly over tank baffle.(Does not �9 Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks n Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. .9 Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risers (4" dia, pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) Adequate ❑ High water table ,K Low ❑ Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate O Drainage ❑System is causing visible surface discharge. COMMENTS: J 23-9-7 Date of Inspection Se6 System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner low On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER �' ' "'U� N/'� ADDRESS �i i�i/ i7 amu• PERMIT NO.'S. 709 ' DATES �3 CONTRACTORS City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is ® an existing system ❑ new construction) ® 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects.relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION! m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks .Z Solids accumulation in tanks indicates they should be pump- have.not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. (9 Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers IV dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) A Adequate ❑ High water table I9 Low ❑ Fair ❑ Lot size ❑Medium 11 Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: Date of Inspection teptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner O � O CITY of ORONO v, titi Municipal Offices W; Street Address: Mailing Address: $EggO 2750 Kelley Parkway P.O. Box 66 1/ Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner_ Address:1180 Wyndmere Rd. Permit #'s:7098 Dates:8/15/83 Contractors:Westonka Plbg. (This is X an existing system [ ] new construction) STEM COMPLIANCE (1-3) : 1 `1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [� has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) DF,L.INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system acre and condition soils etc. ) : medium COMMENTS: 01 194 PC r 1,4 Date of of Inspection V8e tic S stem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 0 FAX 473-0510 CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON-SITE SEWAGE TREATMENT INSPECTION REPORT �'�9kESH04�G Owner: L) / m Add—dress: Permit #"s: -Dates: (L 1 Contractors: /w��� hYl I Ill• City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is 91 an existing system I I new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or I I has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tp inspection indicates: 157 Pumpout not needed at this time. �'6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. ranks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed to each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Drainfield inspection indicates: ry;n acing evident. ome evi urfacing, not crit+�Am Drat aturar t lyb discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): COMMENTS: ate of-Inspection Septi System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT INSPECTION REPORT ti ��9kEsH0��O Owner: Address: ime /� i�'12�/P /Cri, Permit #'s: Dates:Q/5-Sr3 Contractors: G cess, �/ar City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is P6. an existing system I ) new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM'--A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic I ) has or tk has not been identified at this time. If the limiting soil characteristic has not been identified, this c assification may be subject to revision.) TANK CONDITION (5-10): Tp4 inspection indicates: (5) Pumpout not needed at this time. `5 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D Vfield inspection indicates: (]Y Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): / COMMENTS: Date of Inspection Xeptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENTCIT INSPECTION REPORT OF POST OFFICE BOX 66 O_ONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER /ONIUe— SuN k/#Lk ADDRESS 122349 1A)VND1,✓Ia-)e� /0D, PERMIT NO.'S. X09 — DATES - —� —g� CONTRACTORS WE�.S7 A194 L"OS'- City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. y� (This is X an existing system ❑ new construction) IX' 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating K� properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. M4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION.( (0 Checked items may require your action) Tank'nection indicates: El Inspection pipe is located directly over tank baffle.(Does not Puspmpout not needed at this time. give accurate measurement of solids accumulation.) If tanks Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Dram 'eld inspection indicates: should be pumped out as soon as possible. ^Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Fut ur Expansion ❑ Soil tabl nd system condition) , 4dequate El High water table Low ❑ Fair ❑ Lot size Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible /j surface discharge. COMMENTS: 2, Date of Inspection tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner O O CITY of ORONO Municipal Offices Street Address: Mailing Address: �'q�Egg0g2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: LCI Address:1180 Wyndmere Rd. Permit #1x:7098 Dates:8/15/83 Contractors:Westonka Plbg. (This is ,[/}. an existing system [ ] new construction) 'STEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level M has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) PRAINFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. 1 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: i Date of Inspection 8 is System In pector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-73S7 a FAX 473-0510 //p p CITY of ORONO 15/ Municipal Offices 44 Street Address: Mailing Address: 9$EggO�' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 j Owner: bf, �� ! 1 Address: 1180 Wyndmere Rd. Permit Vs: 7098 Dates: 8/15/83 Contractors: Westonka Plbg. (This is ✓\] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3O Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is EV] or is not [ ] identified under this septic system. If the saturated soil level is not iddohtified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9Q Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is K] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) V1INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008. Date of Inspection ep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-73S7 • FAX 473-0510 ? CITY of ORONO ' `�►� i� ; :! �ti btuniclpal Offices Street Address: ��Hog 2150 Kelley Parkway Malliny Address: P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 9sa-Act-4600 I To Current Owner: Address: $y w nd rf\rr e- Pi City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An isTs which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. (�3 )"14ON-COMIPUANT SYSTEM" A prohibited ISIS;an ISIS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which h failing for any reason;and any ISIS with less than three feet of unsaturated sail or sand between the distribution device and the limiting soil characteristics. TANK CONDITION ffi-2): S Tank inspection indicates: © Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ), Make sure septic tanks are pumped through manhole and not through white inspection pipes This allows for the proper cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. INFIELD CONDITION(S-10): CY 8 Dminfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CoWaNTS: y'(.�c\� (�Cn— l0�. �:�fi c�•.`I fh\1 — to , `�r1' J���` C_ �+rFS Qcu 4z ,o Date of Inspection Matt Bolterman- Septic System Inspector Note:in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property.be advised that this report does not gusrsate: orccn*that an existing system will continue to function properly,but is merely an opinion ofthe adequacy c the system tinder current conditions based on the availabi. information. - = CITYof ORONO �l4 Municipal Offlces Street Address: Mailing Address: 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 June 20, 2000 Younki Kim 1180 Wyndmere Road Wayzata, Mn 55391 Dear Mr. Kim: An inspection of your septic system was conducted on June 19, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year (last pumpout 11/15/96). The septic system is non-compliant due to a lack of a three foot separation distance between the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic system must be replaced no later than December 31,2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. c , C is Pence u/ On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)2494600 • Fax(952)249-4616 www.ci.orono.mn.us k CITY of ORONO Municipal Offices Street Address: Mailing Address: 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 To: The Current Owner of Address ( 182 LJ-4^ 644ye City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The,onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Ide Yes n/tified as Non-Compliant � No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 W__ � Other Septic Tanker Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every threeears. City records indicate the tank(s) were last pumped out on I (" I � . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: Ins ecto - - V� --_ � Date of Inspection (P -©Cv Telephone(952)249-4600 - Fax(952)249-4616 www.ci.orono.mn.us CITY of ORONO Municipal Offices Street Address: c15a-a49-460 o Halling Address: 2750 Kelley Parkway P.O. So 66 Orono, MN 55356 Crystal flay, UN 55323-0066 To Current Owner: 1�D in t r Atitiress: I � C City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM"_An ISIS which meets all the location,design and construction standards of the current nt Orono Municipal Code. 2 "COMPLIANT SYSTEM" An LSTs which does not meet all the location,design and construction tion standards of the current Orono Municipal Code but does meet the three foot separation requirement or two hoot requirement for system installed 1996 or earlier,and which is not fading or an imminent threat to public health or safety. 6"NON-COMPLIJANTSYSTEM' A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISIS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which a failing for any reason;and any ISIS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: 5 Pumpout not needed at this time. Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. v Tank was last pumped 1. Make sure septic tanks an aamoed tibrewgh manhole and not through white inspection pipes. This allows for the Proper cleaning. Keen water sofiaer and.iron filter discharge Out of septic system to Prolong life of draiafield Ask Pu atr to test alarm float to verde alarm is still working in your house The alarm warns owner that SWtage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): —Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is sattuated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: �r a:��<tl� � (o b� at�N--Lo)y Date of Inspection Matt Bolterman- Septic system Inspector Note: In the event that Wig inspectim report is used to satisfy the requirements for a mortgage or other transfer of property,be advised drat this report does not guawntee or ceitify that an existing system will continue to funcbion properly, but is merely an opinion of the of the adequacy syr ander current conditions based an the available information.