Loading...
HomeMy WebLinkAboutOnsite sewage treatment system o o CITY of ORONO Municipal Offices Street Address: °i5d,-Jt49-46o O Mailing Address: 2150 Kelley Parkway P.O. Boot 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. STEM CONFORMITY (1-3): 1 "CODE Sygnborl An LOTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does mea the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not mea all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks nice pumped through manhole and not through white inspection Pipes. This allows for the proper cleaning. Kew water sett eer and iron fitter discharge out of septic system to Prelone life of drainfietd. Ask pumper to test alarm float to verify alarm is still working in your house. The alarm warps owner that septaee is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINIULD CONDITION(8-10): d ®DmMeld is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: Date of Inspection Matt Boherman- Septic System inspector Note: In the event that this iospection report is used to satisfy the requirements for a mortgage or other ttmkr of property,be advised that this report does not guarantee or eer*that an existing system will continue to fund properly,but is merely an opinion of the adequacy of the system under current conditions based on the available hiformatiw. � ? CITYof ORONO ' � •r�r� i ��� `• Municipal OlFces Street Address: Malling Address: 2150 Kelley Parkway P.O. Bax 66 Orono, MN 55356. Crystal6ay, MN 55323 006 cisa-*n-4600 To Current Owner: Address: ( 6 S n��r�t• �- City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. lie on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. _SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM"An ISTS which meets all the location,design and eonstrucilon standards of the current Orono Municipal Code. 2. "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems Installed 1996 or earlier,and which Is not failing or Q) .an imminent threat to public health or safety. -NO-,4-COMPLiANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which Is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(r-:7): Tank inspection indicates: 5 Pumpout not needed at this time. OSeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Q Tank was last pumped 11-1—d flake sure septic tanks are pumped through manhole and not through white Inspection pipes This 211o«s for the prover cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRATNFIELDCONDITION(S-10): �Sj Dminfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repa'tn must be completed within 90 days. COtifENTS: ��:��.•clt;� rd�- (a M 1;5�� q� r�.�S�- /C kcc cl �� Date of inspection Matt Bolterman- Septic System Inspector Note:in the event that this inspection report is used to satisfy the requirements for a mortgage*rather transfer ofpmpery.be advised that this report does not gum"—"' Of certify that an existing system will continue to function properly,but is merely an opinion o f the adequacy o f the system under current conditions based on the availab Information. CITY of ORONO Municipal Offices Street Address: Mailing Address: 7E81't0g' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 June 20, 2000 Back Hong 1165 Wyndmere Road Wayzata, Mn 55391 Dear Mr. Hong: An inspection of your septic system was conducted on June 19, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year(last pumpout 9/29/95). The septic system is non-compliant due to a lack of a three foot separation distance between the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic system must be replaced no later than December 31,2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. Re ectfiilly, Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)2494600 • Fax(952)249-4616 www.ci.orono.rnn.us CITY of ORONO Municipal Offices Street Address: Mailing Address: \�' EggOg' 2150 Kelley Parkway P.O. Box 66. Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: Address: 1165 Wyndmere Rd. Permit Vs: 7448 Dates: 5/31/84 Contractors: Sullivan (This is X] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous � codes and is functioning properly. 131 Non-Compliant System: System may or may not meet current City standards for design, ��,,// construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [�] or is not [ ] identified under this septic system. If the saturated soil level is not id ntified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 0Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are E ] or are not E ] water tight or the condition is [X] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 (lV Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008. R__2 1-3 Date of Inspection e i System Inspdct6r Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 9 FAX 473-0510 CITY OF ORONO 0 Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a ON—SITE SEWAGE TREATMENT INSPECTION REPORT 9kEsH0 Owner:�S L6m2Address: Rd. Permit Id's: Dates: '" Contractors: �Ikl1"1 City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is A] an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 11 10 "CODE SYSTEM11-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or I ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours t0 eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (41' dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accura eaew s . s accumulation). If tanks have not been pumped out within the last three years, s ould be pumped out 7 DRAINFIELD CONDITION (11-14): AbOp mal- )iL Dfield inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): COMMENTS: Date of Inspection Sept'c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO 0 Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT INSPECTION REPORT �kES, 0 Owner: Rkk 9121A Address: #Ks- JW Permit #'s: Dates: Contractors: 57, 1-or\ City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is Q4 an existing system I l new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic I l has or D-has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Isl Tinspection indicates: Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been Pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr field inspection indicates: Drainfield is dry, no surfacing evident. 1 . Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): COMMENTS: Date of Inspection SWptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY of ORONO Municipal Offices Mailing Address: Street Address: 2150 Kelley Parkway P.O. Box 66 kE8H ,� Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address I I ('5 (,NCAA L4 AA04E- City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The.onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No ✓ If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes 1/ No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other Septic Tank(s)Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out eve three years. City records indicate the tank(s)were last pumped out on I.-, ' O A . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: Ins e ` Date of Inspection P Telephone(952)249-4600 • Fax (952)249-4616