City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
STEM CONFORMITY (1-3):
1 "CODE Sygnborl An LOTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does mea the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not mea all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7):
Tank inspection indicates:
Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks nice pumped through manhole and not through white inspection Pipes. This allows for the proper
cleaning. Kew water sett eer and iron fitter discharge out of septic system to Prelone life of drainfietd. Ask pumper to test
alarm float to verify alarm is still working in your house. The alarm warps owner that septaee is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINIULD CONDITION(8-10): d
®DmMeld is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
Date of Inspection Matt Boherman- Septic System inspector
Note: In the event that this iospection report is used to satisfy the requirements for a mortgage or other ttmkr of property,be advised that this report does
not guarantee or eer*that an existing system will continue to fund properly,but is merely an opinion of the adequacy of the system under current
conditions based on the available hiformatiw.
� ? CITYof ORONO '
� •r�r�
i ��� `• Municipal OlFces
Street Address: Malling Address:
2150 Kelley Parkway P.O. Bax 66
Orono, MN 55356. Crystal6ay, MN 55323 006
cisa-*n-4600
To Current Owner: Address: ( 6 S n��r�t• �-
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
lie on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
_SYSTEM CONFORMITY (1-3): 3
1 "CODE SYSTEM"An ISTS which meets all the location,design and eonstrucilon standards of the current Orono Municipal Code.
2. "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems Installed 1996 or earlier,and which Is not failing or
Q) .an imminent threat to public health or safety.
-NO-,4-COMPLiANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which Is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(r-:7):
Tank inspection indicates:
5 Pumpout not needed at this time.
OSeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Q Tank was last pumped 11-1—d
flake sure septic tanks are pumped through manhole and not through white Inspection pipes
This 211o«s for the prover cleaning.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
DRATNFIELDCONDITION(S-10):
�Sj Dminfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repa'tn must be completed within 90 days.
COtifENTS: ��:��.•clt;� rd�- (a M 1;5�� q� r�.�S�- /C kcc cl
��
Date of inspection Matt Bolterman- Septic System Inspector
Note:in the event that this inspection report is used to satisfy the requirements for a mortgage*rather transfer ofpmpery.be advised that this report does not gum"—"'
Of certify that an existing system will continue to function properly,but is merely an opinion o f the adequacy o f the system under current conditions based on the availab
Information.
CITY of ORONO
Municipal Offices
Street Address: Mailing Address:
7E81't0g' 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323.0066
June 20, 2000
Back Hong
1165 Wyndmere Road
Wayzata, Mn 55391
Dear Mr. Hong:
An inspection of your septic system was conducted on June 19, 2000. A summary of the inspection
is below.
Septic Tank Condition
1. Pumpout needed within one year(last pumpout 9/29/95).
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City
Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic
system must be replaced no later than December 31,2010.
Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also
enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
Re ectfiilly,
Chris Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be
advised that this report does no guarantee or certify the existing system will continue to function properly,but is
merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)2494600 • Fax(952)249-4616
www.ci.orono.rnn.us
CITY of ORONO
Municipal Offices
Street Address: Mailing Address:
\�' EggOg' 2150 Kelley Parkway P.O. Box 66.
Orono, MN 55356 Crystal Bay, MN 55323.0066
Owner: Address: 1165 Wyndmere Rd.
Permit Vs: 7448 Dates: 5/31/84 Contractors: Sullivan
(This is X] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
� codes and is functioning properly.
131 Non-Compliant System: System may or may not meet current City standards for design,
��,,// construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [�] or is not [ ] identified under this septic system. If the
saturated soil level is not id ntified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
0Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are E ] or are not E ] water tight or the condition is [X] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
(lV Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic
system is required by 12/31/2008.
R__2 1-3
Date of Inspection e i System Inspdct6r
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 9 FAX 473-0510
CITY OF ORONO 0
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 a ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
9kEsH0
Owner:�S L6m2Address: Rd.
Permit Id's: Dates: '" Contractors: �Ikl1"1
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is A] an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): 11
10 "CODE SYSTEM11-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic has or I ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Punpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours t0 eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (41' dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accura eaew s . s accumulation).
If tanks have not been pumped out within the last three years, s ould be pumped out
7
DRAINFIELD CONDITION (11-14): AbOp mal- )iL
Dfield inspection indicates:
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope.setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.):
COMMENTS:
Date of Inspection Sept'c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO 0
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
�kES, 0
Owner: Rkk 9121A Address: #Ks- JW
Permit #'s: Dates: Contractors: 57, 1-or\
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is Q4 an existing system I l new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic I l has or D-has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): Isl
Tinspection indicates:
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been Pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
1 .
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope.setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.):
COMMENTS:
Date of Inspection SWptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY of ORONO
Municipal Offices
Mailing Address:
Street Address:
2150 Kelley Parkway P.O. Box 66
kE8H ,� Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Current Owner of Address I I ('5 (,NCAA L4 AA04E-
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The.onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No ✓
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes 1/
No
If yes, system must be brought into compliance by:
December 31,2007
December 31,2010
Other
Septic Tank(s)Pump out Needed
Yes
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out eve three years. City records indicate the tank(s)were last pumped out on
I.-, ' O A . The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleaning.
Comments:
Ins e ` Date of Inspection
P
Telephone(952)249-4600 • Fax (952)249-4616