Loading...
HomeMy WebLinkAboutSeptic System Site Plan 10./14/97 05:56 V612 937 5822 WESTWOOI> PRO SVS Gi Pj-'f'2vHAG,P N EVAI UA SON&DF,,vuiv 816,56- 10`x' St. Delano, AIN 55328 (h 12) 972-2110 October 13, 1997 Qilbert Anderson 845 So. Willow Drive Wayzata, NLN 55391 TLE: Septic System Site Plan Dear Gilbert. After malting a site visit to 845 South Willow Drive, I have determined that the area you have picked as a potential garage site would not make a suitable septic area. This area has. been used for a driveway and turnaround, which makes it unsuitable for sewage treatment. I did, however, find two other potential sites for a three bedroom mound system. One is north of your house and one is south of your house. These sites will require further testing and research to determine if they are suitable for a future septic system. I am enclosing a copy of my notes to show where the potential sites are located. It is critical that the soil in these sites not be disturbed. If you have any questions in regards to this site evaluation, I will be happy to answer them. I aan be reached at (G 1.2) 972-2110, Sincerely, GREENHAGEN EVALUATION ,Paul Greenhagen Septic Site Designer MPCA Lic. No. 283 10/14-97 05:57 $612 937 5522 WESTWI-)OD PRO SE'S oo3• (1o5 845 WILLOW DRIVE Nvrth Site The soil survey labels this as (LRB) Tester loam. I found mottling at 12" to 24" with little to no top soil.. The knoll that this site is on may have had the top soil stripped off it. It needs further research to detern-iine if it is a suitable septic site. Two :soil borings (I recorded) and no perk tests were taken on this site. This site has an 8% slope. No more than a three bedroom mound would fit in this area. South Site The soil, survey labels this as (LRB) fester loam.. I found mottling at a depth of 24". It has a slope of 8%. In order to put a septic site here, a building with no foundation would have to be moved. Also, the south property line should be identified. I took one soil boring and no perk tests. Further research and tesWig would need to be done to determine if this is a suitable septic site. 10/14-'97 05:57 %Y612 937 5122 WESTWOOD PRO SE'S 0 4iii05 \ g•10 � J \ "zn N : �a!/brrf gnrt���sars 8,V S' r;v e, n7bY� hZt 1+ 0 CM N 11) 14,,'97 05:57 $612 937 5522 WESTWOOD PRO SE'S o o.5 iii►5 —LOQ s.QF 014 BOMINGS i acotion or Profact '�E /% or,-1/,f .sou E0ri17gs mode bl av� rrrhf� cam! nn,'r /l7//�^r C/assifcolion System AASHO . USDA-SCS_�` UnifeC o/her Auger used ('check two) : Hond y, or Power. ; F/ighf or Bucket X � ofher depth Boring number Depth Baring number /n feet Surfoce e/evof/an feet S'urfoce elevation Q Munsoll Choet Al y e Munse// Chart d /ow �Ja a= 1w 7 — :�' 7'y8 /0 End of boring of feel. End of how/ng pt / feet. Standing water tab/e : Stond/ng wote4r table Present at feet of depth, Gresent of feet of depth, hours after boring, hours offer boring, Not present /n boring ho/e Not present in boring hole Mottled so// . Mottled sail observed at feel of de tfi. .11 P Observed of !.`� � pf depth. Not present in boring hate Not present /n boring ho% ObserMatians and comirienfs ; Observot/ons and comments 10,,14/97 05:56 $612 937 582-9 WESV OOn PRO S17S f�jU0liUi�5 luj n r it s /-D Q G, O Zl(-)rr ve So u IV cf