Loading...
HomeMy WebLinkAbout2000 HVAC floor planCONCRETE SLAB GOND-1 3 DX 3' • , OPENINGin VALVED FOR PLUMBER 1" 2 PSI GAS METER. 2 1148 CFH TOTAL CONNECTED LOAD 270 MUA) 500 AHU-1 do 2) 378 KITCHEN APPL.)106 UNIT# DX G- _ 1 3�8" SUCTION_ 3/4 LIQUID STORAGE ROOM --- — _ _ ' 1212 MUA DIFF---- MFQ'R MODEL CFM AREA SERVED COOLING TONS w ' x 0 1 2412 MUA DIFF. 550 CFM EA___ (4) THUS MUA PANE KITCHEN EXHAUST HOOD 20X10 CONNECTION �TOH -f 3' DECK 41X38 0/A LOUVER W/ 6X38 PORTION TO BE USED FOR _ COMBUSTION AIR. — _ 3I4» G----a—� t! !11 U-1 !! !! 10" FLUE UP ! ' THRU ROOF !' a 1 AIR HANDLER UNIT SCHEDULE UNIT# LOCATION MFQ'R MODEL CFM AREA SERVED COOLING TONS HTG. IN HTG. OUT VOLTAGE GAS CONN. WEIGHT I240/3 I3/4" REMARKS GREENHECK G -85—D PRV 240 3/8" 1/20 120/1 BACK DRAFT DAMPER EF -2 ROOF I250,000 I200,000 CUBE 180 UPBLAST 2400 AHU-1 ATTIC TRANE GSAA 4000 ASSEMBLY ROOM 10 765 SMOKE DETECTORS, ECONOMIZER, TWO STAGE GAS AHU-2 ATTIC THANE GSAA 4000 ASSEMBLY ROOM 10 250,000 200,000 240/3 3/4" 765 SMOKE DETECTORS, ECONOMIZER, TWO STAGE GAS EXHAUST FAN SCHEDULE UNIT# LOCATION SYSTEM MFG'R MODEL • STYLE CM S.P. H.P. VOLTAGE REMARKS EF -1 ROOF TOILET EXHAUST GREENHECK G -85—D PRV 240 3/8" 1/20 120/1 BACK DRAFT DAMPER EF -2 ROOF HOOD EXHAUST GREENHECK CUBE 180 UPBLAST 2400 1 1/2" 1 240/3 GREASE RATED, VENTED CURB EXTENSION, HINGE KIT EXTERNAL ._ "'/INSULATION 20X48 R/A GRILLE AT CEILING. TYPICAL (2) UNITS AHU-2 III 150 CFM i 1 3/8"UCTION — --------------------, ( i 3/4" LIQID- — — s -- ------ a DX DX 3 F~ f — �s �` 20 1 ! ! ! 4€ ' { 1 i CON _-3/4 DX 1! t 120 i 1! i. i t! COOLING COIL � I t . 412 SAD 1+ I i a 1 LOW CEILING AREA p 00 CMmum 0 -� t-.---- _ _ - - t 1 I I _ � I SURFACE MOUNT KITCHEN^------ _ _ _ �� --- — ------ i ! t DIFFUSERS TO t ' --------------- i 1 1 _ WOOD CEILING 105 I � --- --- _ I I i �Fy % --------------1 EXTERNAL a 1 1 INSULATION T EXTERNAL rill, INSULATION °WOMENS ROOMWATER 14x14 WE 104 HEATER EXHAUST DUCT I a ! ! ! I 1 UP TO PRV EF- 1_ =----------- ---------------- - - - - -- ---------- - - - - -- 80 :1212...SAD 1 - 1202C MG "'120'-C 1 I i 1 '1 MENS ROOM I2414 SAD Q103 CD _� -- 2414 SAD 1000 CM I 1-810 HM EA 1 '''�' HC (4) THUS y k 8} 20' FLOOR PLAN HVAC AIR COOLED CONDENSING UNIT UNIT# LOCATION MFG'R MODEL BTU CM VOLTAGE H.P. UNIT MFG'R MODEL COOLING TONS MCA CIRCUIT BRKR. VOLTAGE WEIGHT REMARKS COND-1 TRANE TTA120C 10 49.4 60 AMPS 240/3 480 INTERLOCK W/ HOOD EXH. FAN COND-2 TRANE TTA120C 10 49.4 60 AMPS 240/3 480 ---------- ------1212 1212 EAG 1212 SAD VAULTED CEILING AREA })qE 120 CM 120 CFM 1 EXPOSED STRUCTURE 1 ** -- — — — — —— — — — — — —— DROP COAT ROM l � ' EXPOSED DUCT 1a2 i a � — — — — — -- — — — — — — — 1212 SAD t 1 120 CM ENTRY VESTIBULE r. r -------------------- ___ 101 i 20' FLOOR PLAN HVAC AIR COOLED CONDENSING UNIT UNIT# LOCATION MFG'R MODEL BTU CM VOLTAGE H.P. UNIT MFG'R MODEL COOLING TONS MCA CIRCUIT BRKR. VOLTAGE WEIGHT REMARKS COND-1 TRANE TTA120C 10 49.4 60 AMPS 240/3 480 INTERLOCK W/ HOOD EXH. FAN COND-2 TRANE TTA120C 10 49.4 60 AMPS 240/3 480 GAS MAKE-UP AIR UNIT SCHEDULE UNIT# LOCATION MFG'R MODEL BTU CM VOLTAGE H.P. S.P. GAS CONN. WEIGHT REMARKS MUA-1 SLAB RUPP RAM -10 270,000 2500 240/3 2 1.15 1/2" 1080 INTERLOCK W/ HOOD EXH. FAN GENERAL NOTES: 1. ALL GAS PIPING TO BE SCHEDULE 40 GALVANIZED WITH THREADED FITTINGS 2" AND SMALLER. FITTINGS LARGER THAN 2" TO BE WELDED. 2. LOCATE STRUCTURAL FRAME OPENINGS TO MAINTAIN FULL CLEARANCE WITHIN CURB I.D. DIMENSIONS. 3. CONCEALED DUCTWORK SHALL BE EXTERNALLY WRAPPED WOODHILL COUNTRY CLUB N® d MN BARN REMODELING FLOOR PLAN - HVAC REVISIONS m AW _ I! PY LIVV V G VIV VLR IlG V� IfIL JI/"11L ian4'ry F I N SQTA. 0 CO DATE '� � REG. N0. 24742 THIS D ING IN DESIGN AND DETAIL IS OUR PROPERTY AND MUST NOT BE USED EXCEPT IN CONNECTION WITH OUR WORK. ALL RIGHTS OF DESIGN AND DETAIL ARE RESERVED. 1�Q�M'Je� (y_t2-of CHECKED BY: WHH DRAWN BY: RMH DATE: 7/ 13/00 PROJECT MGR: WHH M-1 J01 -1t0 E00-1 19