HomeMy WebLinkAbout2001 - P04060 - mechanical PERMIT CITY OF ORONO 250 Kelley Parkway - PO Box 66 Permit Number: P04060 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 7/9/2001 SITE ADDRESS: 880 Windjammer Lane Mound,MN 55364 PID: 07-117-23-11-0013 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 187.50 Valuation: $ 15,000.00 State Surcharge Fee: $ 7.50 TOTAL FEE: $ 195.00 APPLICANT: Apex Heating&Cooling OWNER: John&Alexa Horoshak 312 Newton Ave SE 880 Windjammer La Watertown,MN 55388 Mound MN 55364 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. "7,APPLICANT PERMITEE SIGNATURE UED BY SIGNATURE Copies: 1-File(Signitures Required), 1-Applicant, 1-Monthly Reports, 1-Assessing, 1-Finance Page 1 0 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: New Addition Repair Replace %/ Residential Commercial JOB SITE: g 5-A - Zip: 5-S 3 6 �}- Owner's Name: -5p1A J..l o Iz s Ys A kc.. Telephone Number:612 ?act G19 5 V Mailing Address: x -s 1-1 u-0124-14,AR-AA City: eg.o nro Zip: 5 5 3 ( 4— Contractor's Name: A?E x ' Cr Telephone Number:9 5 2 9 S S 2 S Mailing Address: 31 . N E J'ro N 1e . S. E City:w (Z?b&Zip: S 5 3 32 SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: 1 _ Make: c2-AM Model: `R-VR a /0 Fuel: U T Flue Size: Input BTUs: q O,OCY3 /9, coo Ggit A)()— Output BTUs: 9 00 CFM: -2ooC) COOLING SYSTEMS Quantity: Make: C-OL6AkA Model: 4 Cxo 3 tl X 122 1 Tons: 3 H. Power . A - FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Cr()0 Model No. ? •—moi �3 VENTILATION No. I Kitchen Exhaust / ducted recirculating j S 0 cfm No. A Bath Exhaust (must be ducted outside) -,c,Q cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas:• gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) /5000 x .0125 $ (contract price) 2., State Surcharge: **,Add the State BuildingCode Division • _ Surcharge to each permit. x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: a--�f� P't Date: --t - 9 - 0 Approved By: Date: Heat Loss Calculation Worksheet For: Apex heating and cooling inc. City: Orono Contractor!Owner: John Horoashak Job Address: 890 Windjammer Ln. Calculated with Delta T of 90 Amount "U" Factor Factor BTUH Loss Square feet of exposed wall area above grade: 3010 0.05 13545 Square feet of exposed window area: 1800 0.55 89100 Square feet of ceiling area: 2350 0.03 6345 Square feet of basement/crawl space floor area: 1400 0.03 3780 Square feet of wall area below grade: 2080 0.09 16848 Linear feet of infiltration for windows: 1990 0.5 1.085 1080 Linear feet of infiltration for doors: 204 1.25 1.085 277 Linear feet of infiltration for sliding doors: 589 0.75 1.085 479 Allowance for kitchen and bath fans Kitchen fans @ 600 BTUH: 1 600 600 Bath fans @ 200 BTUH: 4 200 800 Allowance for fireplaces @ 1300 BTUH: 2 1300 2600 Total BTUH loss: 135454 Add for combustion air(.001 x net x 12.5 x.075 x 90): 11429 Total: 146882 Maximum allowable(Total x 115%) 168915 BTUH output of furnace must fall between: 146882 and 168915 Date: / / ! I Signature: a----11-A" -- Z ' CITY OF ORONO /CALLED IN �� INSPECTION NOT /� TIME SCHEDULED PERMIT NO. 0 ' ' COMPLETED _ /- i ADDRESS '5 O CU 11-t-i /' ��IIm'r (.�C' OWNER n�-CCONTR. 770P; ' TELEPHONE NO. ,n /. —S9 7 ,/ DESCRIPTION ILC(k 1 nj W 01 FOOTING 11 MECHANICAL RI 18 XCAV/GRADING/FILLING W 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y O 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL • 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT -.I 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP IL 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL ▪ OWNER/CONTRACTOR TO MEET YOU:_YES NO o 17MENTS: C(�I `vp V' /41--e-- .. - A aCC 'Cf•d'tlJ�- ci;--TACIP—P/OC4-114.1 >, CC 0 W CC Q W Z W CC O IQ• ❑WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE W KIORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY OO ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlContr tor on site: Inspector ‹g--€-- White GrimmWhite Copy/Inspector's File Canary Copy/Site Notice