October 18, 2017
RECEIVED
Aaron Lutz OCT 1 U ,201
Outdoor Excapes
2345 Daniels Street CITY OF ORONO
Long Lake, MN 55356
RE: Boulder Retaining Wall Typical Section
500 Willow Drive South
Orono, Minnesota
Project No. 17-2989
Dear Mr. Lutz:
This letter includes important details regarding the attached design for the boulder retaining wall typical
engineered sections at the above location. This design is based on a Certificate of Survey prepared by
Gronberg &Associates dated September 14, 2017, and a wall layout plan provided by you.
The attached typical section(s) should be referenced for construction details. Special note should be
made of the wall embedment depth and the geosynthetic fabric (geogrid) length as measured from the
front face of the wall if applicable. If water is encountered at the base of the wall, additional drainage and
reinforcement details may be required.
Refer to industry standard practice references for installation information, specifications, and details.
- Boulders shall be placed to avoid continuous joint planes in vertical directions.
- Each stone shall bear on two or more rocks below it with good flat-to-flat contact.
- Compact any structural fill place behind the drainage zone to 95% standard proctor.
- Install woven landscape fabric behind the stone to limit soil migration through the wall face.
- Optional drainage stone shall consist of clean 3/4"to 1.5"crushed stone
The design of the wall system is specific to the following parameters:
• Location: Back of house at window well; 6-foot single wall with split to two 3-foot tiered walls
• Minimum embedment depth = 6", or as noted
• Soil conditions: Sandy Clay, friction angle = 30.0 degrees, unit weight of 120.0 Ib/ft3
• Allowable soil bearing capacity= 1,500 psf
• Surcharge loads behind the walls: None
• Slope at top: 10:1; Slope at bottom: 10:1
• Boulder sizes: see cross section drawing
• Geosynthetic Reinforcement Fabric Type: None
• Drainage pipe: Required
LICENSED
PROFESSIONAL
ENGINEERS
HOME&BUILDING INSPECTIONS
STRUCTURAL EVALUATIONS
ASSOCIATION RESERVE/TRANSITION STUDIES
RESIDENTIAUCOMMERCIAL 5
RETAINING WALL DESIGN&EVALUATIONS
z0l-7--00
500 Willow Drive South, Orono, Minnesota
October 18, 2017
Page 2 of 4
These walls have not been designed for ground water surcharge loads. Direct all surface drainage away
from the walls. Methods to do so include but are not limited to the following: drainage swale, site grading,
retention ponds, etc. Details of water control are left to the wall contractor. Please contact Criterium-
Schimnowski to provide additional site assessment services if desired.
The wall design was performed using the design guidelines presented in the third edition of the "Design
Manual for Segmental Retaining Walls" (DMSRW) published by NCMA in 2009. Additional information
requested by Criterium-Schimnowski Engineers but not available includes: geotechnical site survey and
soil data. If soil conditions, proposed wall layouts, or any other design parameters vary from those stated
above, contact me for a revised design. Please call me if you have any questions or need more
information. Thank you.
Sincerely,
Paul Schimnowski, PE
MN#40126
CRITERIUM-SCHIMNOWSKI ENGINEERS
TEL 651 779-7700
500 Willow Drive South, Orono, Minnesota
October 18, 2017
Page 3 of 4
DESIGN PARAMETERS AND PROVISIONS
DESIGN PROVISIONS:
1. REFER TO BOULDER RETAINING WALL INDUSTRY STANDARD SPECIFICATIONS AS THEY ARE
INTEGRAL TO THIS PLAN
2. THE DESIGN OF THIS RETAINING WALL SYSTEM WAS BASED UPON THE EFFECTIVE STRENGTH
PARAMETERS SHOWN ON THE"SOIL VALUES"TABLE.UNLESS OTHEWISE NOTED,NO FORMAL
SOIL INFORMATION WAS PROVIDED BY THE OWNER OR OWNER'S REPRESENTATIVE.IF SOIL
CONDITIONS VARY AT TIME OF CONSTRUCTION,WALL ENGINEER MUST BE CONTACTED TO
DETERMINE IF A REVISED DESIGN IS NEEDED.
3. THE WALL DESIGN WAS BASED ON THE INFORMATION NOTED IN THE LETTER ABOVE.
4. REFER TO WALL CALCULATIONS FOR BEARING CAPACITY REQUIREMENTS.
5. NO PRODUCT/MATERIAL SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN
PERMISSION OF CRITERIUM-SCHIMNOWSKI ENGINEERS.
6. FINAL SITE GRADES AND ROOF DRAINS SHALL DIRECT RUNOFF AWAY FROM ANY RETAINING
WALL(S).UNLESS OTHERWISE NOTED,THE WALL(S)HAS NOT BEEN DESIGNED FOR
HYDROSTATIC SURCHARGE LOADING.
7. THE WALL DESIGN WAS PERFORMED USING DESIGN GUIDELINES PRESENTED IN THE THIRD
EDITION OF THE"DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS"PUBLISHED BY NCMA.
DESIGN LIMITATIONS:
1. THE INFORMATION PROVIDED WITHIN THESE DOCUMENTS IS FOR THE STRUCTURAL
DESIGN OF THE PROPOSED RETAINING WALL(S)ONLY. THE REQUIREMENTS FOR AND/OR WORK
RELATED TO HANDRAILS,GUARDRAILS,OR OTHER LIFE/SAFETY ISSUES ARE EXCLUDED FROM
THESE DOCUMENTS AND ARE TO BE PROVIDED BY OTHERS.
2. SITE LAYOUT AND GRADING DESIGN ARE NOT INCLUDED IN WALL DESIGN SERVICES.THOSE
SERVICE ARE THE RESPONSIBILITY OF THE SITE CIVIL ENGINEER.
3. INTERNAL COMPOUND STABILITY(ICS)HAS BEEN CALCULATED FOR THIS PROJECT BY
CRITERIUM.HOWEVER,ICS IS NOT A SUBSTITUTE FOR A GLOBAL STABILITY ANALYSIS WHICH
SHOULD BE PERFORMED BY A QUALIFIED GEOTECHNICAL ENGINEER.ADDITIONAL SUBSURFACE
EXPLORATION MAY BE REQUIRED.
SUGGESTED QUALITY ASSURANCE REQUIREMENTS:
1. A QUALIFIED ENGINEER OR TECHNICIAN SHALL SUPERVISE THE WALL CONSTRUCTION TO
VERIFY SITE SOIL CONDITIONS. IF THE PROJECT GEOTECHNICAL ENGINEER DOES NOT PERFORM
THIS WORK,A QUALIFIED GEOTECHNICAL ENGINEER/TECHNICIAN SHALL BE HIRED TO ASSURE
THE RETAINING WALL IS CONSTRUCTED WITH PROPER SOIL PARAMETERS.
2. A QUALIFIED GEOTECHNICAL ENGINEER SHALL BE CONSULTED TO VERIFY THE SUITABILITY OF
DESIGN ASSUMPTIONS MADE BY CRITERIUM.
3. WALL EXCAVATION AND SOILS SHALL BE INSPECTED FOR GROUNDWATER CONDITIONS.THE
GEOTECHNICAL ENGINEER SHALL DETERMINE ADDITIONAL DRAINAGE PROVISIONS TO BE
INCORORATED INTO THE WALL DESIGN.
4. THE WALL DESIGN ENGINEER SHALL BE HIRED TO PERFORM A PRE-CONSTRUCTION SITE VISIT.
5. THE WALL DESIGN ENGINEER CAN BE HIRED FOR CONSTRUCTION OBSERVATION SERVICES.
6. THE WALL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING QUALITY CONTROL FOR THE
CONSTRUCTION OF THE WALL IN ACCORDANCE WITH CONTRACT REQUIREMENTS.
7. SEE PROJECT CONTRACT DOCUMENTS FOR SPECIFIC DETAILS ON THE SCOPE OF WORK THAT
WILL BE PROVIDED BY ALL PARTIES.
I
CRITERIUM-SCHIMNOWSKI ENGINEERS
TEL 651 779-7700
500 Willow Drive South, Orono, Minnesota
October 18, 2017
Page 4 of 4
TERMS AND CONDITIONS
This WALL DESIGN and ensuing recommendations is expressly made subject to the following terms and conditions
to which all persons that receive and rely thereon agree:
1. Standard of Service—Services performed by ENGINEER under this agreement shall be performed in a manner
consistent with the skill and care ordinarily used by members of the engineering profession practicing under similar
conditions at the time and in the locality the services are performed.
• Client recognizes that interpretations and recommendations of ENGINEER are based solely on the
information available to the company.
• ENGINEER will be responsible for those interpretations and recommendations, but shall not be responsible
for the interpretation by others of the information developed
• Services provided reflect the professional judgment of ENGINEER,to the best of ENGINEER's knowledge,
information,and belief as of the date hereof.
• No other warranty or guarantee,express or implied, is made.
2. Said design is based entirely on and expressly limited by the scope of services ENGINEER has been employed by
Client to perform and as described in WALL PROVISIONS and LIMITATIONS.
3. If the ENGINEER is hired for any construction phase services or site visits, it is understood that the Contractor, not
the ENGINEER, is responsible for the construction of the project, and that ENGINEER is not responsible for the acts
or omissions of any contractor,subcontractor or material supplier;for safety precautions, programs or enforcement;
or for construction means, methods,techniques, sequences and procedures employed by the Contractor.
4. OWNERSHIP OF DOCUMENTS:All reports,field data,field notes,calculations,estimates and other documents
('reports')prepared by Engineer,as instruments of service, shall remain the property of Engineer. Client agrees that
all reports furnished to Client or his agents,which are not paid for,will be returned upon demand and will not be used
by Client for any purpose whatever. Engineer will retain all pertinent records relating to the services performed for a
period of five years following submission of the report,during which period the records will be made available to
Client at all reasonable times.
5.TERMINATION:This agreement may be terminated by either party by written notice. In the event of termination,
ENGINEER shall be paid for services performed and expenses incurred up to the termination notice date. Neither
Client not ENGINEER may delegate, assign, sublet or transfer his/her duties or interest in this Agreement without the
written consent of the other party.
7. To the fullest extent permitted by law, Client and ENGINEER(1)waive against each other,and the other's
employees,officers,directors, agents, insurers, partners,and consultants,any and all claims for or entitlement to
special, incidental, indirect,or consequential damages arising out of, resulting from, or in any way related to this wall
design and written report, (2)agree that ENGINEER's total liability to Client shall be limited to the total amount of
compensation received by ENGINEER and (3)if an action is brought against the ENGINEER and the ENGINEER
prevails, ENGINEER shall be entitled to recover costs and expenses, including reasonable attorneys'fees and costs.
CRITERIUM-SCHIMNOWSKI ENGINEERS
TEL 651 779-7700
wl-440V wel� vlqaxll� vm
SOIL VALUES USED IN THE or Pro vlde
DESIGN OF THIS PROJECT r�
FRICTION ANGLE UNIT WEIGHT /OLd d
TYPE OF SOIL (DEGREES) (Ib/ft-3) /
REINFORCED BACKFILL 30 120
RETAINED BACKFILL 30 120
FOUNDATION SOIL 30 120
NUMBER OF BOULDER COURSES
CROSS SECTION DESIGN BASED ON INFORMATION LISTED IN COVER WILL VARY AS NEEDED
LETTER. 18 TO 23 DEGREE SCHEDULE OF REQUIRED
SETBACK, TYP. rIMPERVIOUS FILL BOULDER SIZES
12' DEEP EXPOSED WALL BOULDER DEPTH,
TOP BOULDERS, TYP. HEIGHT MIN,
(12" TO 18" BOULDERS 4' 28'
ALLOWED FOR FINAL GRADE
ADJUSTMENTS) S' 32"
6' 36'
MID—LEVEL BOULDERS, TYP. \\ \\�
OPTIONAL 12" THICK
DRAINAGE AGGREGATE
SEE BOULDER SIZE SCHEDULE
FOR MORE INFORMATION _
6' MAX. I I I I
BASE BOULDERS
2:1 MAXIMUM SLOPE — WALL BACKFILL COMPACTED 95%
OF MAXIMUM STANDARD PROCTOR
ALLOWABLE
HEAVY WOVEN GEOTEXTILE DENSITY
BOULDER i FILTER FABRIC
DEPTH BEHINDI I BOULDERS
WALL EMBEDMENT = 6' MIN. I—
�L1jtlltiilirr��
UNDISTURBED ��—III—III—III-
4" DIA. DRAIN PIPE
SOIL OUTLET 0 END OF WALL 3E OR 0 40' CENTERS MAX ENGIN AL ; Ez
EER
4012E
TYPICAL SECTION — 6' BOULDER RETAINING WALL (HEIGHT VARIES) CIF
�''.' •----•_• 'Q�;a?��
SCALE: NONE "111111411110
Designed
�
Designed By; PROJECT NAME/ 500 WILL❑W DRIVE SOUTH / ORONO, MN Date;
PDS LOCATION: 10/18/2017
Checked By: CLIENT: OUTDOOR EXCAPES Project No;
PDS CRITERIUM-SCHIMNOWSKI ENGINEERS 2345 DANIELS STREET 17-2989
161 DUNBAR WAY PHONE:651.779.7700
Scale MAHTOMEDI,MN 55115 FAX:651.779.71 l4 LONG LAKE, MN 5535620 F6-FT
awing Name:
AS NOTED pschimno(r�criterium-schimnowski.com PHONE: 952-292-9772 BOULDER WALL
SOIL VALUES USED IN THE
DESIGN OF THIS PROJECT
FRICTION ANGLE UNIT WEIGHT
TYPE OF SOIL (DEGREES) (Ib/ft-3)
SCHEDULE OF REQUIRED REINFORCED BACKFILL 30 120
BOULDER SIZES RETAINED BACKFILL 30 120
EXPOSED WALL BOULDER DEPTH, FOUNDATION SOIL 30 120
HEIGHT MIN.
4' 28' CROSS SECTION DESIGN BASED ON INFORMATION LISTED IN COVER
5' 32' LETTER.
6' 36' TOP BOULDERS, TYP.
7' 38• (12" TO 18" BOULDERS
8' 42• ALLOWED FOR FINAL GRADE
ADJUSTMENTS)
NUMBER OF BOULDER COURSES \/�
WILL VARY AS NEEDED \�
18 TO 23 DEGREE BASE BOULDERS 3', MAX.
SETBACK, TYP.
TOP BOULDERS, TYP. i VARIES
(12" TO 18" BOULDERS 0 WALL BACKFILL COMPACTED 95%
ALLOWED FOR FINAL GRADE �� 1 r� 'A r vie,
I OF MAXIMUM STANDARD PROCTOR
ADJUSTMENTS) \ Ut/ 4 'V v/ f l DENSITY
12" THICK SELECT GRANULAR f(
MID—LEVEL BOULDERS, TYP. \\� / SAND OR DRAINAGE AGGREGATE F / 1 4-41
® //►
(OPTIONAL) � /
GEOSYNTHETIC REINFORCEMENT FABRIC / V'1 d-a
5', MAX. 2 LAYERS ® 5'-0" LONG MIRAFI 3XT OR Q IVALENT
BASE BOULDERS
>til I/ 5 b e 1•erm e yl a n 75/ Q -pl�e
HEAVY WOVEN GEOTEXTILE
BOULDER FILTER FABRIC
DEPTH BEHIND BOULDERS WALL BACKFILL COMPACTED 95%
OF MAXIMUM STANDARD PROCTOR
WALL EMBEDMENT = 6' MIN. ( DENSITY all
AL
�77
UNDISTURBED , I III—III—III— 4" DIA. DRAIN PIPE ENGIINEER '
SOIL OUTLET ® END OF WALL 46126
OR ® 40' CENTERS MAX �j,••�
TYPICAL SECTION - TIERED BOULDER RETAINING WALL (HT. VARIE ''�'�`'
S) OF 4P,'
SCALE: NONE
''J'���
Designed B
9 Y PROJECT NAME/ Date:
PDS LOCATION: 500 WILLOW DRIVE SOUTH / ❑R❑N❑, MN
10/18/2017
Checkfd By: CLIENT: OUTDOOR EXCAPES Project No:
PDS CRITERIUM-SCHIMNOWSKI ENGINEERS 2345 DANIELS STREET 17-2989
161 DUNBAR WAY PHONE:651.779.7700
Scale: MAHTOMEDI,MN 55115 FAX:651.779.7114 LONG LAKE, MN 5535620 Drawing Name:
AS NOTED pschimno(uicriterium-schimnowski.com PHONE: 952-292-9772 TIERED BOULDER WALL