Loading...
HomeMy WebLinkAboutRusty Olson's Soil/Percolation Testing - May 5, 2017 r ORONO Copy 3 " 13-0 �S Joseph Olson D.B.A. & � Rusty Olson's--Soil and Percolation Testing Joseph J. Olson--MPC A License #810 1 11481 Rivervie%v Rd. NE, Hanover, :VIN 55341 (763) 498-8779 Fax (763) 498-8290 Revised May i,?017 THIS SWEM IS DESIMB FOR NOR-SON -BEDROOMS. ANY INCREASE IN DUMBER 100 �%ihow Drive S OF BEDROOMS INVAUDKES THIS DESIGN. Orono. Hennepin CountN This on-site Sewage 7 reatment System is partially designed for a Type l five-bedroom ]tome and a : bedrooill.guest house in accordance with the Minnesota Pollution Control Agenc} Chapter 7080 and local ordinances. t!t+; riodicaliy saturated soils were located at 12-16 inches(mottled soil). Due to the periodically saturared soils.a pressurized mound system with 6 inches of rock%%ill need to be installed to treat the septic effluent. {he oottom o the treatment area must be located at least 3' above the saturated soils.This system is designed with 6 incks of rock. .r A lift pure-needed in the lo%%est level of the house to keep tanks shallow as per code. Al: neighboring %%ells are greater than 100' from proposed treatment areas. 4 The soils at a depth of 12"have a percolation rate averagiag 10 MPI. T. 1500-gallon septic tank needs to be installed for the house and the guest house. The two buildings are to be connected to the same septic tanks. Ail ne\v tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs must be installed on the end of the laterals for maintenance. A 500 gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The Power supply and switches must be located outside the manhole and pumping chamber in a Aeatherproof enclosure-.A vyarning device must be installed with light and sound devices:this is in case of pump fai(ltr yv measurement device must be installed. Including but not limited to a water meter,event counter, rtinni tatUige6cks or electronicall) controlled dosing. Nothirtf-A other tharl a%-water.(faundrv.showers etc ) Human water and toilet tissue should be disposed of tcto the senttc tanks. Garbage disposals are not recommended Additives must not be used, the% rnay cause harmful damage to your septic s%stem It is recommended that you Pump the tank ever% year for I septic tan6 every two nears for t%%o seotic tanks Sircere;v. CITY OF ORONO 4-"' SEPTIC PEWIT PLA X IE Joseph Olson INSPECT R DATE PERMITNO.Wtj� A PRQvrD AS SCBMITTrD APPROVED WITH CORRECTIONS As noTFn NOT APPROVhD-CORRECT&USGBMIT ThesF vonuncots are for your information. All work shall he dope In lull eompli:utcc with all applicable septic and zoning code. Rvc iuiremcnts including items not specilically noted in this review. KI-.i:l' i HIS PLA\SI:T ON SITE'AT ALL]IME.S N ,a FUTURE G /� °ARKfNG EA / r c' i 1 _ a �1YdJyk r rr �P N ZC 77 n z Sr e-7 5A .\ �--_yam c �i g� �_ � /•;n-. , 3 C 1 70 --------------- -_----3-�—U-----` -r ti— -- /...._— . - - - ._-- — - �.Mc C Ano^ICCA^C 411 ItA• _ -.__. _ -- _- �" a =c j•� •w C �,, ;,, T L4 a J 01. L r :y v tt �Cco ra /�S r arm t y „� f p� Cg �Y • r � = t l its, i i wf�) MMFF i� 2011 purplecoce Mound Design www.SepticResource.com (vers 15.2) Property Owner: NOR-SON Date: 5/5/2017 Site Address: 500 Willow Drive S PID: 0311723320017 Comments: 5 Bedroom house and one bedroom guest house Inst:unions: IT =enter data =adjust if desired = computer calculated - DO NOT CHANGE; '- ! 6 ilbedroom Type I Residential System 900 !GPD design flow Yes (Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks J 3000 JGai Septic tank (code minimum) 3000 Gal Septic tank (design size / LUG req'd) Tank options: none ( 1.7 ;GPD/ft' mound sand loading rate contour loading rate of =req's a min 75 ft. tong rockbed ! 1O.0 !ft rockbed width 175.0 ft rockbed length I 3.O-,ft lateral spacing3.0 ft perforation spacing (maximum of 3 for both) end feed manifold connection s (laterals 73.0 ifeet long 25.0 perfs / lateral 75 perts total (1/2 a pert means the first pert starts at the middle feed manifold) 7/32 inch perfs at feet residual head gives O.Sb gpm flow rate per perforation `or th:;s perf size Et spacing, 8 pipe size on tine 12, max perfs/latera( = 30 , line#8 must be less > 4.0 1doses per day ( 4 minimum) r 225 {gallons per dose (treatment volume) 2.CC inch diameter laterals must be used to meet'Ax pipe volume" requirement 2.00 Sx feet of 2.0 inch supply line leads to =gallons of drainback volume 2.00 3x i 229 }gallons TOTAL pump out volume (treatment* drainback) (Tip: "top feed"manifold to control the drainback) 9 ;feet vertical lift from pump to mound laterals, leads to a: 42 GPM lz feet of head, Pump requirement (note: >50gpm may require an extra 3 b of head) 900 1gai Dose tank (code minimum) 1500 gal Dose tank (design size / LUG req'd ^reads to a ) at29.4; 1g„ S; 7.8 hrlch swing on Demand float, or timed dosing of 5.5 min ON (confirm pump rate with drawdown (this delivers Average flow, =70%of Peak design flow) 9 hrs OFF11 test and adjust as necessary)IL-1 J from bottom of tank to"Pump OFF"float 1 20 linches from bottom of tank to"Pump ON"float, or I 12 inches to'Timer ON"float if time dosed 23 inches from bottom of tank to"Hi Level"float, or 33 inches to"Hi Level"float if time dosed -- I 82 gallons reserve capacity�J p y (after High Level Alarm is activated) - =gpd/ft' Absorption area Soil Loading Rate, which gives a mound ratio of 2.7 (this must match the soil boring tog) (minimum) r 7,percent site slopedesired mound ratio 2.7 (0 2C% range) �(%downslope site slope, if different than upstope) l�15- i.n es, or 1.3 eft. to Redox or other limiting condition Treatment zone contains inches of 0%Soil credit, and (need 0 inchestof250%sc l credi a Type I' 20 in or 1.7 ,ft. Sand Lift Mound t. Giving a: CRITICAL FOR FUTURE CERTIFICATIONS!!! 27.00 ?ft-Total ABSORPTION width (with sand beyond rockbea as follows:) L0.0ft. upstope and sideslope 1:7.0jjft. Downslope Incividual slope ratios give BERM widths (topsoil beyond rockbed) of: - i 4:1 iupsiope ratio11 ft, upslope berm 4:1 Isidesiope 17 ;ft. sideslope berms r—� i ail laowr.s;ope 24 !ft. downslope berm Overall Dimensions: 10.0 ft. wide by 75.0 ft. long Rock bed 1 45 ft. wide by109 ft. long Mound footprint 4" inspection pipe Ups(ope ber18" cover on top m 11 Downslope berm 24 12" cover on sides 1,7 Uear) sand lift (6"loamv cap&6"topsoil) 1.31; Absorption Width 27.0 Note: -For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Width is measured downhill from the upstope edge of the Bed. Rock Bea: ' ft. by fft. by 75.0 - inches underi e plus 20%gives 25 yd or 1.4= p p ' p � =ton Mound Sana: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) 41.5 yup + i 117.9 downslope r 16.8 ends, 7 —under rock= 279 yd'or`1.4- ;• Foamy Cap: plus 20% i 390 ton 41 ft. by F 105 ft. 6"deep, ptus 20%gives 96 yd'or'1.4= 1j347ton Topsoil: 45 ft oY ' 109 ft. 6"deep, plus 20%gives 109 yd'or"1.4= 1­15-3-Iton j i nereby certify that 1 have compteted this work in accordance with all applicable ordinances, rules and laws. Rusty Olson's Soil a Perc esigner Signature 810 Company 5/5/2017 License# Date installer Summary 130001gallon Septic tank (minimum) Tank options: none :)u;b larger tanK with rnurupte comp/Lancs `L 500 igallon Dose tank (minimum) . 42at 29.41 gpi LjGPM 16 ft. of head, Pump required finch swing on Demand float which translates to roughly 4.9 inches of float tether length if time dosing is required --> 5.5 minutes ON time& hours OFF time ! 20 inches from bottom of tank to"pump ON"float, or �33 ]inches inches to"timer ON"float I 23 inches from bottom of tank to"Hi Level Alarm"or to"Hi level alarm" if time dosed '22 —'ft. of 2.0 inch supply line with Fen_df_eed___j manifold connection 1 2G incn, or (Tip: "top feed"manifold to control drainback) P2.00 ft. Sand Lift Mound 10.0 ft. wide by ft. long Rock bed 3�laterals inch diameter 7+ /32(inch perfs ft. perforation spacing ?3.0 ft. long 3.0 ft. lateral spacing No Effluent fitter it alarm 3 clean out& valve box assemblies 2�Vft.Total, sand ABSORPTION width (minimum) 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) 17.0 ,ft. Downslope Specific slope ratios give BERM widths (topsoil beyond rockbed) of: 4:1 upstope ratio F 11 !ft. upslope berm 4:1 isidestope 17 'ft. sideslope berms 4:1 ldownstope .24 ft. downslope berm 4" inspection pipe �---� 18" Cover on top U slope berm LL 1 i Downsto a berm 24 12" cover on sides 1.7 Clean Sand lift (6 loamy cap&6°topsoil:; - n'l1oil fi Absorption Width 27•a Note: For 0 to 1° slopes, .46sorption Width is measured from the Bedequatly in both directions. For slopes >1.6, Ahsorotion WSdth is measured downhill from the upslope edge of the Bed. i Rock Sec: 25.0 yd'or`1.4= 35 ton 6 inches under pipe McLnc Sand: 279 yd or`1.4= 390 Lon calculation based on 3:1/4:1 slope from top of rockbe, 'carry Cap: 96 yd or`1.4= 134 ton Topsoil: 109 1yc3 cr`1.4= 6"deep 153 ton 6"deep u;i wu:ow ur:ve INSPECTOR CHECKLIST - mound � � 20'to pressure tested sewer line (5 psi for 15 min) 50'to everything 100'to dispersal area with shallow well '10to everything ' platted: 10'prop tire. Metes ti bounds: out of road easement, or outer ditch. .AK :3LLF setht:ek: 20'for bluff. GD r—� Lakes: RD _, NE Protected wetland � i3tiii�iia�=,ern�.:s: 10for eve s .-- �--; ' everything, 20'for dispersal area. u LINE a;,JC1 rrrSSurr Sc 10'to bed,tank ft sewer line. (else sewer line > 11"below) i Sewer line & baffle connection (no 90's, Y between 45's, slope min 1"in 8', max 2"in 81 i o depth req's, clean out every 100', Sch 40 pipe) r— i✓ Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) mfE 3000 gallons none Riser over outlet, riser over iniet or center, and 6"+ inspection pipe over any remaining baffles. ---i No effwent fitter&alarm Dose tank risers and piping (water tight, insulated, proper depth, drainback) mfg ______ 1500 gallons close pump 42 gpm 16 head VERIFY PUMP CURVE 5.5 min ON 9 hr OFF float setting drop 7.8 inches at 29.4 Bpi "DESIGNED" 4.9 inches approx float tether-length 229.0 gal dose divided by Bpi "INSTALLED"= LABEL pump requirements and drawdown on riserinches float drop (field corrected Iii Cam lock reachable from grade - 30" max. J-hook weep hote.Supply line access (no hard 90's) 2.0 inch supply pipe: Sch40, sloped 1/8"+ Pe supported by 4"sch40 sleeve or compacted, and buried 6"+. ~ sp,ice box / control panel / electrical connections (i flow measurement: CT, E;M, time dosed, home water meter mound absorption area rough up mound rocK dimensions ---- 10.0 X 75,0 Sand lift depth 20 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) Absorption Sand beyond rock 0.0 u sic p pe 17.0 downslope Bermed topsoil beyond rockbed 11 u sto p pe 4.7 sidesiope 24 downslope cover depth of 12-18"* VERIFY 3 laterals (1-2'from edge of rock) 2.00 inch pipe size (Sch40 pipe lY fittings) 3.0 ft lateral spacing 7/32 nch perforations 3.0 ft perforation spacing Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY ?_ :::ean ours i.no hard 90's) J 4"inspection pipe to bottom of rock, anchored VERIFY ADaneon existing system - if necessary (_ Re use existing tank certification monitoring plan, and type well abandonment form - if necessary System Elevations bencr,mark r - - -, - - (Grade elevations are existing. If a Mound t different final grade is desired it should loamy cap be shown and described here.) lateral bottom rock grade (Al OW-lope lock bed) SHV VT (-It up+lope to(k bed) AAA 1 r f Sewer pipe exiting house Septic Tank Septic Tank Pump Tank Grade _ _ Grade Grade Grade Pipe inlet inlet inlet Tank bottom Tank bottom ___� Tank bottom Soil Observation Log "%%%%.SepticResource.com vers 12.4 Owner Information Property Owner,project: NOR-SON Date 10/?7/?016 Property Address ;PID: SOU Willow Drive S Sourvey Information ❑ refer to attached 78edrock Elandscape ❑ TiII ❑ Outwash r^ ❑ Lacustrine _ Alluvium ❑ Organic [ tion: ❑ Summit (-] Shoulder tC Side slope ❑ Tce slope units: L22C'2 slope 7 °o direction-Convex Soil Log#1 ❑ Boring t❑ Pit Elevation 951.9 Depth(in) Texture fragment°o Depth to SNWT 16 Inches g matrix color redox color consistence grade shape P 0-6 Topsoil <35 10yr3:2 Loose Loose Single grain 6-16 Clay Loam <35 IOyr4 3 Friable Strong Blocky 16-24 Clay Loam <35 10yr5'4 IOy4 8.1-6 10y Finn Strong Prismatic <35 loose loose 35 -50 triable singly='rain weak granular block+ '50 firm moderate prismatic plat} rigid strong ntassi+c <35 loose loose 0 iable single grain fr -5 +reak ,ranular block% >50 ,inn moderate prismatic plan rigid strong massive Comments: I I 500 Willow Drive S Soil Log#2 C Boring ❑ Pit Elevation 951.9 Depth(in) Texture fragmem 4b Depth to SHWT l6 Inches matrix color redox color consistence grade shape 0-4 Topsoil <35 10}r4 Loose Loose Single grain 4-16 Clay Loam <35 10yr d Friable Strong Block% 16-24 Clay Loam <J5 10}T5 4 10%4'8,1-6 10} Finn Strong Prismatic <35 Loose loose single grain 35 -50 friable weak granular bluckv >50 firm moderate prismatic piaty rigid strong massive <35 loose loose single grain 35 -50 friable weak granular nlo,:k_v >50 Lunt moderate prismatic platy rigidstrong massive 500 Willow Drive S Soil Lo #3 Boring [] Pit Elevation 952.8 Depth to SHWT 12 Inches Depth(in) Texture fragment 4o matrix color redox color consistence Grade shape 0-6 Topsoil <j5 10yr4:? Loose Loose Single grain 6-12 Clay Loam <35 10yN—4 Friable Strong Lilocky 12-24 Clay Loam <35 10}•r5.4 104:8.1-6'IOy Firm Strong Prismatic <35 loose loose single grain 35 -50 friable weak granular block-% >50 firm moderate prismatic platy rigid strong massive x=35 loose loose singly grain 35 -50 friable weak granular blocky >50 firm moderate prismatic plan rigid stroma ma+sive /he>>•ehv c•el.o-this»ork tray cwinpleled it,acc orcla1,ce u•/t/r a%!' -()80 01,41 all,.local rey'r. Rusty Olson's Soil R. Perc 810 esigner Signature Company License r a 500 willow Drive S .;SIS if L Boring C pit E Ie�attosl :" Depth to SHWT j? Depth(in) Texture fragment°, matrix culo N olor -consistence tirade shape 0-6 Tiap<<�il <35 IOyr3 2_ Loose Loose Single gram 6-12 Clay Loam I0 r4 Friable Strong Block.\ 12-24 Clay Loam <,; IO\r; .4 10y4 8.1-6'10 Firm Strong Prismatic 35 loose loose single ain 35 .50 friable weak granulaVNockv >50 14 Finn moderate prismal +plate �+ rigid strong massive loose loose 2 friabsingle grain 7Z firm le Weak ' granular hlucky moderate prismatic ptirft 5 Drive h( < "� rigid strong massive Soil Loe#5 L:�j Boring ❑ pit Elevation 951.9 Depth(in) �"ixture fragment°b Depth to SHWT ] matrix color redox color consistence grade shape • s. 0�4 ; Topsoil <35 M\r4 ,_ Loose Loose single grain; _- 4-16 Clay Loam <35 l Oyr4.4 Friable Strong Blockv 16-34 Clad Loam -35 10\r5 4 10\4 8.1-6 10\ Fit-III Strong Prismatic loose<�� lIOOSe . 35-50 single grain friable weak granular hlock) '50 Finn moderate prismatic plan rigid strong masshe ,5 loose loose single=rain 35-50 friable weak granular hla:kv 50 firm moderate prismatic plan rigid strong massive /hertht•c•Yrtlti•Jhi.e work rias c•rntp/eted in urcorc/curce,rich:bJ:�',-(lti'O and u►n'loco/rey:c. es er.Signature Company ` . License 4 Soil Observation Log %%1%W.Sept icResaurce.ct�m vers 12.1 Owner Information Property Owner'project: NOR-SON Date 10/27/2016 Property Address!PID: 500 Willow Drive S Soil Survey Information ❑ refer to attached soil survey r1andscape Q Till ❑ putwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock tion: ❑ Summit [] Shoulder J L] Side slope C l Toe slope units: L22C slope 7 °'o direction- Convex Soil Loe#6 ❑ Boring ❑ Pit Elevation 951.3 Depth(in) Texture fragment°�o Depth to SH WI' 18 Inches matrix color redox color consistence grade sha e 0-14 Topsoil <3 5 10yr3'_2 Loose Loose Single grain 14-18 Clay Loam <35 10Yr4 3 Friable Strom, Mockp 18-24 Clad Loam <,5 1ONr5 4 IOV41.1-61Ov Finn Strong Prismatic <i5 loose loose single gram 35 -50 friable weak granular blocky '10 firm moderate prismatic plate rigid strong massive <3s loose loose 35-50 friable single grain weak gTa7)Ulilr hlnrk� "0 firm moderate prismalie plan rind strong massi�•e i Comments: Soil Observation Log tt�.5epticKesource.u�m tern I?.4 Owner Information rftpert�\ r ,project: NOR-SON Date 4!1/2017 ess PID: 500 Willow Drive S. Soil SU vy Information El refer to attached soil survey Parent mati's: Till Outwash Lacustrine [^�Alluvium r Organic 77 U Bedrock landscape position: ❑ Summit C Shoulder r Side slope ❑Toe slope soil survey map units: L=':�C slope 1-9 °o direction- convex Soil Log#7 Lz�i Boring 77, Pit Elevation 950.0 Depth to SHNVT 16 Inches Depth(in) Texture fragment°'o matrix color redox color consistence arade shape P 0-6 Topsoil <3; 10yr4.2 Loose Loose sinLte grain 6-16 Loam <35 10yr5 4 Friable Strong Blocky 16-20 Clay loam <35lOrrS 4 10y-1 8,1-6`l0y Friable Strong Bl�ckN 20-24 Cia} Loam <35 10\T64 10y4'8,1-6'IOy Friable Strom, e BlockN <35 loose loose ,in`te gain 35 - ;0 friable weak sranular hkkkr »0 firm moderate prismatic platN. rigid strong masire Comments: 500 Willow-Drive S. Soil Log#8 21 Boring r Pit Elevation 952.3 Depth (in) Texture frig �� Depth to SHWT 20 Inches stent o matrix color redox color consistence !_rade shape 0-8 Topsoil <35 l 0yr4 Loose Strong Su,glc grain 8-20 Clay Loam <35 l 0vr5 4 Friable Strong Black\ 20-24 Clay!.Dant <:35 10vr5 4 1Oy4 8.1-6'l0y Friable Strong BI„ckv m t� '61064 PZ- 1 ���H �., /—iraG� ac 500 Willow Drive S. Soil Log#9 Boring ] Pit Elevation 952.E Depth(in) Texture fragment 0• � Depth to SHti`T 2D Inches �ment o matrix color redox color consistence evade shape 0-8 Topsoil <35 10\r3 2 Loose Loose Sinelc!rain 8-14 Loam <35 I Oyr4; Friable Strom Bluekv 14-20 Clay Loam <35 10yr5:4 Friable Strom, Block\ 20-24 Clay Loam <35 l OrrS 4 10 4'8,1-6'1 ON Firm Strong Prismatic <35 loose loose _50 sin�lc grain 31 friable weak -ranular block >5O ftrm moderate pri,matic plate rigid strom_� niassi\c /hereht c�rrtifi this trvrk .,,,Is completed in ac cordcrirce with IIN 7080 and ant•logia/reqs. ,,'7 - Rusty Olson's Soil & Perc. 810 esi�**ser nat,urr Compare License -- License Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 10:36 A.M. On 10/28/16 Location: 500 Willow Drive S Hole number: 1 Date hole was prepared: 10/27/16 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6 Dark Brown Loam 10yr3/2 6-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 10/27/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time TimeDepth Drop in H2O 10:56 11:26 6" Perc Rate 11:29 11:59 6" 3.7 8.1 12:00 12:30 6" 3.6 8.3 3.6 8.3 AVERAGE PERC. RATE 8.2 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by Rusty Olson,s Perc. starting at 10:36 A.M. On 10/28/16 Location: 500 Willow Drive S Hole number: 2 Date hole was prepared: 10/27/16 Depth of hole bottom_12"_inches, Diameter of hole 6"_inches. Soil data from test hole: —' Depth, inches Soil texture 0-4 Dark Brown Loam 10yr3/2 4-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 10/27/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O 10:57 11:27 6" Perc Rate 11:28 11:58 6" 3 2 9.4 12:01 12:31 6" 3.1 9.6 3.1 9.6 AVERAGE PERC. RATE 9.5 MPI i f Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 9:15 A.M. On 3/20/16 Location: 500 Willow Drive S. Hole number: 3 Date hole was prepared: 3/19/16 Depth of hole bottom_12"_inches, Diameter of hole_6'_inches. Soil data from test hole: Depth, inches Soil texture 0-6 Dark Brown Loam 10yr3/2 6-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 3/19/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O 9:32 10:02 6" Perc Rate 10:05 10:35 6" 3.5 8.5 10:40 11:10 6" 3'4 8.8 3.3 9.1 AVERAGE PERC. RATE 8.8 l I Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 10:27 A.M. On 4/2/17 Location: 500 Willow Drive S Hole number: 5 Date hole was prepared: 4/1/17 Depth of hole bottom_12"_ inches, Diameter of hole_61_inches. Soil data from test hole: Depth, inches Soil texture 0-8 Dark Brown Loam 10yr4/2 8"12 Brown clay loam 10yr5/4 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 4/1/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O 10:37 11:07 6" Perc Rate 2.2 13.6 11:10 11:40 6" 2.1 11:41 12:11 6" 14.3 2.1 14.3 AVERAGE PERC. RATE 14.1 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 10:27 A.M. On 4/2/17 Location: 500 Willow Drive S Hole number: 6 Date hole was prepared: 4/1/17 Depth of hole bottom_12 inches, Diameter of hole 6'_inches. Soil data from test hole: — Depth, inches Soil texture 0-8 Dark Brown Loam 10yr3/2 8.12 Brown loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 4/1/17 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Dropin H2O 10:38 11:08 6' Perc Rate 11:09 11:39 6" 2.1 2.1 14.3 11:42 12:12 6" 2.1 14.3 14.3 AVERAGE PERC. RATE 14.3 Mpl