Loading...
HomeMy WebLinkAboutRusty Olson's - Soil/Percolation testing - Oct. 31, 2016 Joseph Olson D.B.A. Rusty Olson's--Soil and Percolation Testing Joseph J. Olson--MPCA License#810 11481 Riverview Rd. NE, Hanover, MN 55341 (763)498-8779 Fax (763) 498-8290 October 31,2016 NOR-SON 500 Willow Drive S Orono,Hennepin County This on-site Sewage Treatment System is partially designed for a Type 1 five-bedroom home and a I bedroom guest house in accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. Once the house size, location, lowest floor elevation and septic primary and future sites are chosen this design can be completed. The periodically saturated soils were located at 12-16 inches(mottled soil). Due to the periodically saturated soils,a pressurized mound system with 6 inches of rock will need to be installed to treat the septic effluent. The bottom of the treatment area must be located at least 3' above the saturated soils.This system is designed with 6 inches of rock All neighboring wells are greater than 100' from proposed treatment areas. The soils at a depth of 12"have a percolation rate averaging 10 MPI. A 2250 combination septic tank needs to be installed for the house and a 1500 gallon combination for the guest house.The guest house is to be built first.The 1500 gallon combination tank should be used as a holding tank until the house is built. All new tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs must be installed on the end of the laterals for maintenance. A 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area.The power supply and switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device must be installed with light and sound devices;this is in case of a pump failure.A flow measurement device must be installed. Including but not limited to a water meter,event counter,running time clocks or electronically controlled dosing. Nothing other than gray water,flaundrv.showers etc)Human water and toilet tissue should be disposed of into the septic tanks Garbage disposals are not recommended Additives must not be used: they may cause harmful damage to your septic system It is recommended that you pump the tank every year for I septic tank,every two years for two septic tanks Sincerely, Joseph J. Olson w i o /30.2 / oL9r cn 96ZY o3901do d s v J o I Ch 3 INS 3snOH 3anl :j t ' x � w i I _. 5 _ -_ _ �� --9642___ -9{O—_ O 4l�il� /v.-soil Monw. SU Qwftr fw Me" tc 44ia to JUAM WA AMAPA c can OCIVA �'ts-S G-�.cs 13cr� . l.4ts SOIL BORING ELEVAIMU MOUND SYSTF m UES16W T1141 lit-. jjI.7 fYPN_L -.4. t3_droorn,Average j'rcoiation rate 4 �oTR#2 EL..-isl9 9614)_gal/day _75i)--�-ft of trr�at,nenl 4rea 7SL sy��rust b�: THA E1..-29-k _ Il1U ft. width.- 7f it. length cif hed area ' &rt *5 EL.- 11 -- - tS,..�:'�011i Pto�sti7r tine �• Side slope rua Mrd.«q fivm wdu .16 E..«�S�(. 3 L to i x 3, „eight= ys .X Ott t.au�n aria, t Clear rock r+nededp!us 209'fl 9!r—cu-yds. r�faNliiOilt IiliQ2t ��f Gi>E1 tit4'!te. ...f$t36;1'S Coarse crashed san3.53 cu.Yds. average sand depth 2,gfr �'t�ait metr#+iron,� (MM vMperty Clot. Sandy foam Cu_y . 1epsaii&" R1 c!�. �U 6(MI welts yd5.plus SO% CU.Yds- C30- b idctrrr Mumbo of tanks? I't tank,;�SaDgals.,X"tank_ ._.gals..Pumpdtarnber Capacityljogais_ ISJJI.at �vrna v�_r,at1 rot' fUt. f 14o.ftc Rah./100 lineal feet of_ dia- Supply pipe,linea#feet needed -- I y; ; Soo ��!�� 5 ` Uis;rihutionr ---- - � _���=....1N•o.��.lrY P pe-o -v..+�- o�_Ig lineal feet, dia-Perforations 3(, -apart gloat set at,---- _—gals_, Limeser P day Pump curve__-- /ruin------¢eet head pressure. Daft.'!O !tom Ph- 163.49"779 2011 purple code Mound Design www.SepticResource.com (vers 15.2) Property Owner: NOR-SON Date: 10/30/2016 Site Address: 500 Willow Drive S PID: 0311723320017 Comments: 5 Bedroom house and one bedroom guest house instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE! Ibedroom Type Residential System ,, 900 GPD design flow 31 Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks 4) 3000 Gal Septic tank (code minimum) 3000 Gal Septic tank (design size / LUG req'd) Tank options: none 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 75 ft. long rockbed c,) 10.0 ft rockbed width 75.0 ft rockbed length 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) end feed manifold connection laterals 73.0 feet long 25.0 perfs / lateral 75 perfs total (1/2 a perf means the first perf starts at the middle feed manifold) Q 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation for this perf size Et spacing, Et pipe size on line 12, max perfs/lateral = 30 line#8 must be less > G lo) 4.0 doses per day ( 4 minimum) 1 1 225 gallons per dose (treatment volume) 2.00 5x 12) 2.00 inch diameter laterals must be used to meet 'Ax pipe volume" requirement 2.00 3x feet of 2.0 inch supply tine leads to ##### gallons of drainback volume (Tip: "top feed" manifold to control the drainback) 141 gallons TOTAL pump out volume (treatment + drainback) 1s) feet vertical lift from pump to mound laterals, leads to a: 16) 42 GPM @ ##### feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) 17) 900 gal Dose tank (code minimum) 900 gal Dose tank (design size / LUG req'd) at gpi leads to a 18) ###### inch swing on Demand float, or timed dosing ofOhrs min ON (confirm pump rate with drawdown (this delivers Average flow, =70%of Peak design flow) OFF test and adjust as necessary) 19) 12 inches from bottom of tank to"Pump OFF" float inches from bottom of tank to"Pump ON" float, or 12 inches to "Timer ON"float if time dosed 21) ###### inches from bottom of tank to"Hi Level"float, or ##### inches to "Hi Level"float if time dosed 22) ###### gallons reserve capacity (after High Level Alarm is activated) 23) 0.45 gpd/ft` Absorption area Soil Loading Rate, which gives a mound ratio of 2.7 (minimum) (this must match the soil boring log) desired mound ratio 1 2.7 ,4) percent site slope (0-20% range) �(%downslope site slope, if different than upslope) ,„ 16 inches, or 1.3 ft. to Redox or other limiting condition (need at least 12" to be a Type 1) Treatment zone contains=0 inches of 0%soil credit, and =inches of 50% soil credit. Giving a: 26, 20 inch, or 1.7 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONS!!! 27) F27.0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:) 28) 0.0 ft. upslope and sideslope 17.0 ft. Downslope Individual slope ratios give BERM widths (topsoil beyond rockbed) of: 4:1 upslope ratio 11 ft. upstope berm 3" 4:1 sideslope 17 ft. sideslope berms 3i) 4:1 downslope 24 ft. downslope berm Overall Dimensions: 10.0 ft, wide by 75.0 ft. long Rock bed 45 ft. wide by 1 109 ft. long Mound footprint 4" inspection pipe 18" cover on top U sto a berm 11 Downslope berm 24 12" cover on sides (6"loamy cap&6"topsoil) 1.7 Clean sand lift _ _ 1.3 Depth to Li �'' Absorption Width 27.0 Note: For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. For slopes >1%, Absorption Wrdthis measured downhill from the upslope edge of the Bed. 33. Rock Bed: 10.0 ft. by 75.0 ft. by ®inches under pipe, plus 20% gives 25 yd'or-1.4= 35 ton 34) Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) 41.5 up + 117.9 downslope + 16.8 ends + 56.0 under rock = F-2-79-]yd'or"1.4= 390 Ton plus 20% 3 Loamy Cap: 41 ft. by 105 ft. 6"deep, plus 20%gives 96 yd'or"1.4= 134 ton 30) Topsoil: 45 ft. by109 ft. 6" deep, plus 20%gives 109 yd'or"1.4= 153 ton I hereby certify that I have completed this work in accordance with at(applicable ordinances, rules and taws. Rusty otson's Soil £x Perc 810 10/30/2016 esigner Signature Company License# Date Installer Summary 3000 gallon Septic tank (minimum) Tank options: none :)u70 rdrger Ldnrc wnn rnuurNre c.urnN/WIM, 900 gallon Dose tank (minimum) at =gpi 42 GPM @ ##### ft. of head, Pump required ###### inch swing on Demand float which translates to roughly ##### inches of float tether length if time dosing is required --> ##### minutes ON time It ##### hours OFF time ###### inches from bottom of tank to"pump ON"float, orginches inches to "timer ON"float ###### inches from bottom of tank to "Hi Level Alarm"or to "Hi level alarm"if time dosed Oft. of 2.0 inch supply line with end feed manifold connection (Tip: "top feed" manifold to control drainback) 20 inch, or 1.7 ft. Sand Lift Mound 10.0 ft. wide by 75.0 ft. tong Rock bed 3 laterals 2.00 inch diameter 73.0 ft. tong 3.0 ft. lateral spacing 7/32 inch perfs 3.0 ft. perforation spacing No Effluent fitter & alarm 3 clean out & valve box assemblies 27.0 ft.Total sand ABSORPTION width (minimum) 0.0 ft. upstope and sideslope (sand beyond rockbed, minimum) 17.0 ft. Downslope (sand beyond rockbec, rriimmurr Specific slope ratios give BERM widths (topsoil beyond rockbed) of: 4:1 upslope ratio 11 ft. upslope berm 4:1 sidestope 17 ft. sideslope berms 4:1 downslope 24 ft. downslope berm 4" inspection pipe 18" cover on top U slo a berm 11 Downslope berm 2a 12" cover on sides (6"loamy cap&6"topsoil) 1.7 Clean sand lift 27.0 ..._ _. Absorption WidthE27-0 Note: For 0 to 1% slopes, Absorption Width is measured from the Bedequatty in both directions. For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. Rock Bed: 25.0 yd3 or"1.4= 35 ton 6 inches under pipe Mound Sand: 279 yd3 or"1.4= 390 ton calculation based on 3:1/4:1 slope from top of rockbe, Loamy Cap: 96 yd3 or*1.4= 134 ton 6" deep Topsoil: 109 yd3 or*1.4= 153 ton 6"deep INSPECTOR CHECKLIST - mound wW willow Unve WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) 50'to everything 100'to dispersal area with shallow well PROPERTY LINES setback: 10'to everything Road setback: platted: 10'prop line. Metes 8t bounds: out of road easement, or outer ditch. LAKE BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE_. Protected wetland_. Building setbacks: 10'for everything, 20'for dispersal area. WATER LINE under pressure sc 10'to bed,tank Ft sewer line. (else sewer line > 12"below) Sewer line 8 baffle connection (no 90's, Y between 45's, slope min 1" in 8', max 2"in 8') (no depth req's, clean out every 100', Sch 40 pipe) El Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) Mfg 3000 gallons none Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. No effluent filter&alarm Dose tank risers and piping (water tight, insulated, proper depth, drainback) Mfg 900 gallons dose pump 42 gpm ######head VERIFY PUMP CURVE ##### min ON ###### hr OFF D float setting drop ##### inches at gpi "DESIGNED" ##### inches approx float tether length ##### gal dose divided by gpi "INSTALLED"= inches float drop (field corrected LABEL pump requirements and drawdown on riser or panel Cam lock reachable from grade - 30" max. J-hook weep hole. Supply line access (no hard 90's) 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. splice box / control panel / electrical connections flow measurement: CT, ETM, time dosed, home water meter mound absorption area rough up mound rock dimensions 10.0 X 75.0 Sand lift depth 20 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) El Absorption Sand beyond rock 0.0 upslope 17.0 downslope Bermed topsoil beyond rockbed 11 upslope 17 sideslope 24 downslope cover depth of 12-18"+ VERIFY 3 laterals (1-2'from edge of rock) 2.00 inch pipe size (Sch40 pipe ft fittings) 3.0 ft lateral spacing 8 7/32 inch perforations 3.0 ft perforation spacing Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY clean outs (no hard 90's) 4"inspection pipe to bottom of rock, anchored VERIFY Abandon existing system - if necessary �Re-use existing tank certification monitoring plan and type well abandonment form - if necessary System Elevations ; benchmark . - r _ _ _ _ SHV'JT Mound r (Grade elevations are existing. If a loamy cap different final grade is desired it should lateral be shown and described here.) bottom rock grade (at upsbpe o«k bed) SHWT (at upslope rock bed) 1 1 1 1 r r � Sewer pipe exiting house Septic Tank Septic Tank (it appli(able) Pump Tank Grade Grade Grade Grade Pipe inlet inlet inlet Tank bottom Tank bottom Tank bottom Soil Observation Log %vw".Sept icResource.com vers 12.4 Oi�ner Information Property Owner/project: NOR-SON Date 10/27/2016 Property Address'PID: 500 Willow Drive S Soil Survey Information refer to attached soil survey Parent matl's: Q Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock landscape position: ❑ Summit LI, Shoulder Q Side slope ❑ Toe slope soil survey map units: L22C2 slope 7 4% direction-Convex Soil Log 41 Q Boring ❑ Pit Elevation 95 1.9 Depth to SHWT 16 Inches Depth(in) Texture fragment% matrix color redox color consistence _rade shape 0-6 1 0r`o i 110 r Loose Loose Single grain 6-16 Clay Loam <35 10yr4/3 FriahlrStromz Block% 16-24 Clay Loam --- 1Oyr5/4 IOv4/8,1-6/1Oy Firm Strong Prismatic <35 loose loose single grain 35 -50 friable weak granular block) >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain 35-50 friable weak granular block_N >50 firm moderate prismatic plate rigid strong massive Ccnnments 500 Willow Drive S Soil Log#2 Q Boring ❑ Pit Elevation 951.9 Depth to SHWT 16 Inches Depth (ill) Texture fragment 0,,o matrix color redox color consistence grade shape 0-4 Iupsuil ;� 10%r4 Loose Loose Single grain 16 Clay Loam IOyr4 4 Friable Strong li ock\ 16-24 Clay Loam 10%r_" 4 1 Oy4 500 Willow Drive S Soil Log#4 Q Boring ❑ Pit Elevation 952.8 Depth to SHWT 12 Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-6 Topsoil IOvr3/2 Loose Loose Single grain 6-121 Clay Loam <35 10yr4l3 Friable Strong Blocky 12-24 C laN Loam <35 I 0yr5i4 10x4 8,1-6 l Ov Firm Strono Prismatic <35 loose loose single grain 35 -50 friable weak granular blocky firm moderate prismatic platy >50 rigid strong massive <3 5 loose loose single grain 35 -50 friable weak granular blocky firm moderate prismatic platy >50 rigid Istrong I massive 500 Willow Drive S Soil Log#5 21 Boring F� Pit Elevation 951.9 Depth to SHWT 16 Depth (in) Texture fragment% matrix color redox color consistence grade shape 0-4 Ti olxo i t 5 l Ovm4/2 Loose Loose Single grain 4-16 Clav Loam <35 1Oyr4,,4 FriableStrong Block, 16-=4 Clay Loam IOyr5/4 10 4 8,1-6/IOv Firm Strong Prismatic <35 loose loose single grain 35-50 friable weak granular blocky >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain 35 -50 friable weak granular blocky >50 firm moderate prismatic platy rigid Istrong massive herehy certifp this stork was completed in accordance with AIN 7080 and any local reqs. Z---, L& Svc L r &2 2�ld esigner Signature Company License# Soil Observation Log w%rw.Septic Resource.com vers 12.4 O%%ner Information Property Owner/project: NOR-SON Date 10/27/2016 Property Address/PID: 500 Willow Drive S Soil Survey Information ❑ refer to attached soil survey Parent matl's: Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock landscape position: ❑ Summit ❑ Shoulder ( j Side slope ❑ Toe slope soil survey map units: L22C2 slope 7 % direction-Convex Soil Log#6 El Boring ❑ Pit Elevation 951.3 Depth to SHWT 18 Inches Depth (in) Texture fragment% matrix color redox color consistence grade ;Pape 0-14 Topsoil IOyr3/2 Loose Loose Single grain 14-18 Clay Loam <35 1Oyr4/3 Friable Strong Blocky 18-24 Clay Loam 5 1Oyr5,4 I Oy4/8,1-6/1 Oy Firm Strong Prismatic <.5 loose loose single grain � friable weak granular blocky 35-50 >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain friable weak granular block 35-50 firm moderate prismatic plate >50 rigid strong massive Comments: Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 10:36 A.M. On 10/28/16 Location: 500 Willow Drive S Hole number: 1 Date hole was prepared: 10/27/16 Depth of hole bottom_12"_inches.. Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6 Dark Brown Loam 10yr3/2 6-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 10/27/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 10:56 11:26 6" 3.7 8.1 11:29 11:59 6" 3.6 8.3 12:00 12:30 6" 3.6 8.3 AVERAGE PERC. RATE 8.2 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 10:36 A.M. On 10/28/16 Location: 500 Willow Drive S Hole number: 2 Date hole was prepared: 10/27/16 Depth of hole bottom_12"_inches, Diameter of hole_6"—inches. Soil data from test hole: Depth, inches Soil texture 0-4 Dark Brown Loam 10yr3/2 4-12 Brown clay loam 10yr413 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches.- Date nches:Date of initial water filling 10/27/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 10:57 11:27 6" 3.2 9.4 11:28 11:58 6" 3.1 9.6 12:01 12:31 6" 3.1 9.6 AVERAGE PERC. RATE 9.5 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 9:15 A.M. On 3/20/16 Location: 500 Willow Drive S. Hole number: 3 Date hole was prepared: 3/19/16 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6" Dark Brown Loam 10yr3/2 6-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 3/19/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 9:32 10:02 6" 3.5 8.5 10:05 10:35 6" 3.4 8.8 10:40 11:10 6" 3.3 9.1 AVERAGE PERC. RATE 8.8 MPI Percolation Test Data Sheet Lic.#810 Percolating test readings made by: Rusty Olson's Perc. starting at 9:15 A.M. On 3/20/16 Location: 500 Willow Drive S. Hole number: 4 Date hole was prepared: 3/19/16 Depth of hole bottom_12"_inches, Diameter of hole_6"_inches. Soil data from test hole: Depth, inches Soil texture 0-6" Dark Brown Loam 10yr3/2 6-12 Brown clay loam 10yr4/3 Method of scratching side wall: Knife Depth of gravel in bottom of hole 2 inches: Date of initial water filling 3/19/16 depth of initial water filling 12 inches above the hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic Siphon Maximum water depth above hole bottom during tests 6 inches Time Time Depth Drop in H2O Perc Rate 9:33 10:03 6" 2.2 13.6 10:04 10:34 6" 2.1 14.3 10:41 11:11 6" 2.1 14.3 AVERAGE PERC. RATE 14.0 MPI