HomeMy WebLinkAbout04-20-2005 - poly water service pipe FROM :5072489697 FAX NO. :5072489697 Apr. 20 2005 08:52AM P1 PARROTT CONTRACTING, INC. 30090 STATE HWY 93 HENDERSON, MW56044 (507) 248-9697 (OFFICE & FAX) FAX TO: City of Orono—Mn: Bruce FROM: Dave Parrott SUBJECT: Poly Water Service Pipe DATE: April 20, 2005 NUMBER OF PAGES: Bruce, This fax is in follow up to our conversation this morning concerning using poly water service pipe instead of copper pipe at 1005 Willow View Drive. The reason for this request is two fold, to cut down on friction loss and to eliminate 6 or 7 joints that are always at risk for leaks (the service run is approximately 400'+). The poly pipe today is virtually bullet proof compared to copper and the poly pipe of ten years ago. Following are the specifications of the pipe we intend to use. Thank you, David C. Parrott President 5. <« a(Sc -�-1/ a_ Lc 44.4e. 4,4,nkE FROM :5072489697 FAX NO. :5072489697 Apr. 20 2005 08:52AM P2 n lADr.20.' 2035 7;330, rational WaterwoO.s, 'c; . No'I3k1 P. i 1 EXCEL 80 PSt,ASTM D-22:36.SDR 19,N-S.F SIZE O.D. 1.D. WALL W7/C COIL LGTH. ?/4" .944 _824 .060 7.3 100' & 400' 1" 1,169 1.049 .060 1-1/4" 1,526 1.360 .073 14.8 100' & 300' 1-1/2" 1.780 1,610 .085 20,2 100' & 307 2" - 2 285 .- . 2.067 109 33.1 190' & 200' EXCEL 100 PSI,ASTM D-2239,Sell 15,N.S.F. SIZE 0.0. I.D. WALL WT.'C COIL LGTH 112" .742 ,622 .060 5.6 400' & 400' `r' $14" -944 .824 .060 7.3 100' & 400' r 1.1 g% 1.049 .070 10.9 100' & 300' 1-114- 1.554 1.330 .092 18.7 100' & 300' 1.1/2" 1.824 1.610 .107 26.4 100' & 500' 2" 2.343 2,067 .138 41 a 103' & 200' EXCEL 125 PSI,ASTM D-229% SDR 11.5,N.S.F. S'Z6 O.D. I.D. WALL WT/C COIL LGTI.1. 112" .742 .622 .060 5.8 100' & 400' Il 3/4' .068 .824 .072 &8 100' & 400' 1" 1.231 1.049 .091 14.3 100' & 300' 1-1/4" 1.620 1.380 .120 24.3 100' & 300' 1/1/2" 1.690 1.610 .140 33.6 100' & 300' 2'' 2.427 2 067 130 55 5 100' & 20" EXCEL 160 PSI,ASTM D-2239,SDR 9 .i. SIZE 0.0. I.D. WALL 4YT/r..`, COIL LGTri 314, 1.006 .824 ,092 11.7 100' & 300' 1- 1.283 1.049 .117 18.6 100' & 300' 1-114' 1.686 1.380 .153 32.3 100' 8 300' 1-1:2' 1.36E 1.810 .179 50.1 100' & 300' 2" 2 527 2 087 230 79.5 100- EXCEL 180 PSi,CTS,STM 0-2737.SDR71 SIZE O.D. I.D. WALL WT/C COIL LGTH 3/4" .675 .715 .080 8.7 100' & 500' ., 1.125 .921 .102 14.2 100' & 300' 1-1:4' 1,375 1,125 .125 21.4 100' & 3C0' 1-1/2" 1.625 1.329 .143 29.9 100' & 300' 2" 2 125 1 739 193 51 2 100' EXCEL 200 PSI,I.P,S.,ASTM 0-2233,SUR 7,N.S.F. SIZE 0.0. I.D. WALL atiWT/C COIL LGTH 3/4'' 1.070 .824 .118 15.2 100' 4- 300' +' 1" 1.359 1.049 .150 24,3 100' 'r 300' .-1/4" 1.765 1.380 .197 41.8 100' - 300' 1.1/2" 2.086 1.610 230 58.5 1010' 2" 2 - 2.067 .295 ' - .0' EXCEL 200 PSI.CIS,ASTM 2%37,SDR S,NSF ;"- SIZ0.0. I.D WALL WT/C COIL LGTH. 3/4" .875 .671 .097 10.3 100' 4 500, '' 1" 1.125 .865 .125 16,9 100' 300' i t 1-1/4" 1.375 1.060 .153 24.8 100' r 300- ri -112" 1,625 1.253 .181 34.8 100' 4- 300' • 2" 2125 1637 236 603 100' liz 9, ETA fzi c--- =-14-1----7:-.-,7 _7_7::::,:: :-:._-i-_ :-S. --yrs '5 4 Y te r-=' r. - _ 2 _ ` '. T*