Loading...
HomeMy WebLinkAbout2004 - P07745 - mechanical CITY OF ORONO PERMIT 2750 Kelley Parkway - PO Box 66 Permit Number: P07745 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 2494G00 Date Issued: 7/26/2004 SITE ADDRESS: 985 Willow View Dr Long Lake,MN 55356 PID: 28-118-23-44-0011 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 137.50 Valuation: $ 11,000.00 State Surcharge Fee: $ 5.50 TOTAL FEE: $ 143.00 APPLICANT: Plymouth Plumbing&Heating OWNER: Brenshell Homes 12270 43rd Street NE 4052 Oakland St E St.Micheal,MN 55376 St.Bonifacius,MN 55375 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLICANT PERMITEE SIGNATURE SSUED BY SIGNATURE Copies: 1-File(Siinitures Required), 1-Applicant. 1-Monthly Reports, 1-Assessin2, 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT fox 66 (2750 Kelley Parkway) ` Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: 7.New Addition Repair Replace �Rnesidential .Commercial JOB SITE: �1l' V `'\'' � j_ n '1\i e Zip: Owner's Name: -'ll`'r '/1 1---'1 Q(V IL S Telephone Number: Mailing Address: _ City: Zi � .PLYMOUtH PLUMBING INC. ` Contractor's Name:. Telephone Numbek7'3 5!'6 C.r/cx) 12270 43rd Street N.E. Mailing Address:_ - is -,r,,c / MN _55376-9m _City: f - Zip:_ `.-.,.,t SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: I Make: �,-'�'V( I Model: 2I NISAW'I t 1 Fuel: 'F'kki.u,rzzl Se,.. Flue Size: 4" Input BTUs: 110c 000 Output BTUs: 1 9 c CFM: COOLING SYSTEMS Quantity: I Make: \IAA n U Model: ) ' ''t� Tons: `7 9 / S H. Power {\-2_ . FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. / Kitchen Exhaust ducted ( recirculating cfm No. 4 Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) /1/ 0 a x .0125 $ (contract price) 2. State Surcharge. ** Add the State Building,Code Division Surcharge to each permit. x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50-whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State.Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: 7 Il7/ Approved By: Date: Rhvac-Residential&Light Commercial HVAC Loads is Elite Software Development,Inc.°I Plymouth Plumbing&Heating Brenshell-985 Willow View Oron Brooklyn Center,MN 55428-1662 Page 1 1 Total Building Summary Loads i'' Con1pq a ". Aro 'Sen Lat Sen Total � Descry tt Qua)) Loss Gain Gain Gain;1 3D Window Double Pane Low Emit Wood Frame 699 20,691 0 13,804 13,804 j 11C Door Metal Polystyrene Core 63 2,427 0 552 552 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 3882 17,509 0 3,973 3,973 15G Wall 5' or More Below Grade 8/12" Blk+R-11 736 2,595 0 0 0 161 Ceiling R-44 Insulation 2592 4,889 0 2,325 2,325 19J Floor Over Basement/Encl Crawl Carpet + R-30 924 1,326 0 0 0 21A Basemt Floor 2' or More Below Grade 1651 3,249 0 0 0 Subtotals for structure: 52,686 0 20,654 20,654 People: 10 2,300 3,000 5,300 Equipment: 300 1,200 1,500 Lighting: 0 0 0 Ductwork: 8,476 0 0 0 Infiltration: Winter CFM: 244, Summer CFM: 325 21,356 6,851 5,207 12,058 Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 Sensible Gain Total: 31,502 Temperature Swing Multiplier: X 1.15 Total Building Load Totals: 90,394 11,346 36,227 47,573 Check Figures Total Building Supply CFM: 1,620 CFM Per Square ft.: 0.275 Square ft. of Room Area: 5,894 Square ft. Per Ton: 1,434 Volume (ft') of Cond. Space: 48,803 Air Turnover Rate (per hour): 2.0 TBuilding ng Required4 With Outside Air: 90,394 Btuh 90.394 � � MBH Total Sensible Gain: 36,227 Btuh 76 % Total Latent Gain: 11,346 Btuh 24 % Total Cooling Required With Outside Air: 47,573 Btuh 3.96 Tons (Based On Sensible + Latent) 4.11 Tons (Based On 77% Sensible Capacity) No ` - , Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Brenshell - 985 Willowview Orono.rhv Friday, July 23, 2004, 3:36 PM DAT ,/ TIME 1 CITY OF ORONO CALLED IN lI,. INSPECTION NOTICE SCHEDULED 1 2' -C,7 q:3O 471/4 PERMIT NO. / v7 7 A / COMPLETEDJ ADDRESS 1ecj v_t��lu _' V&t; 'L2,C• jj OWNER CONTR. / ?I in //4, TELEPHONE NO. /&'i X2-(..0 O 3 3 c, DESCRIPTION 70U/lake/T( W 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING 02 FRAMINGECHANICAL FINA---- 19 LAKESHORE/WETLANDS O 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL • 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL Z OWNER/CONTRACTOR TO MEET YOU: YES_NO o COMM TS: -`44.'. ttep x uccic cc cu'vk 0 keL t \ 4..,r- 0 NiJ t_. C‹' O cc L?..T) \4kA... Lu Q VoiAAA.A-e,1"` p J (1ek t.,1....W z W cc d UJ ElWORK SATISFACTORY:PROCEED Il PROJECT COMPLETE W IICORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY CZ ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY OU BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑ CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next spection 24 hours in advance.62/4 (952) 249-4600 Owner/Contrasslc Inspector. � White Copy/Inspector's File Canary Copy/Site Notice