Loading...
HomeMy WebLinkAbout10-15-2007 - roof and decking 1. 0k. r 0 A O CITY of ORONO A 111'- 'til�r Municipal Offices 1 6Y •,� � Street Address: Mailing Address: 44,631.104' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 October 15, 2007 Kara O'Brien 1140 Willow Drive S. Wayzata MN 55391 Dear Ms. O'Brien: I have inspected your existing roof and decking at the request of your contractor. The part of the roof that had the existing shingles tore off indicated that part of the roof is plywood sheathing and part dimensional lumber. The 2006 International Residential Code (IRC, recently adopted July 10, 2007) calls for materials in roof assemblies to be compatible with each other, Chapter 9 section R904 subpart R904.2. The dimensional lumber is thicker than the plywood, resulting in a ridged appearance. The 2006 IRC also states that asphalt shingles must be fastened to a solidly sheathed roof deck. The part of the roof deck that is already sheathed in plywood can remain as it meets the required thickness and appears to be in good condition. The decking to be replaced now does not have to be plywood. It can be OSB if the thickness matches the existing plywood. If there are any further questions please feel free to contact me. Sincerely, k../.16(./ Willie Gibbs Inspections Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us