HomeMy WebLinkAboutSeptic System Inspections °Vv. ' • `ICITY of ORONO Municipal Offices Street Address: Mailing Address: ®�� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 553230066 To: The Current Owner of Address / 0020 [ / ( e `-2 kit City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. • System Identif as Non-Compliant • Yes • No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 .• . • Other • Septic Tan,„1 ,(5.)-rump out Needed Yes '" No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on ci . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: �///���J O AAy {yQp-agyw f Inspector: e` Date 1Inspection . Telephone (952) 249-4600 1172.. (9 2) 2j:9-4626 L>b5'.c'.o'=ono. nn. S (.40;0., 0 0,7:4 4.• CITY of OIIONO \ li Alt e.l.lkiir G~17 Municipal Offices ' - t,'' Street Address:`'�' Mailing Address: Esfio4� 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 553230066 9Sd-A49-4600 To Current Owner: Address: I G a01,-Nis 1k 6s"' Or, fj / City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but docs meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or ci) an imminent threat to public health or safety. "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of t1e current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-.7): e Tank inspection indicates: 5 Pumpout not needed at this time. () Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped r6-151-ell ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CONDITION(S-10): s_ Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. I0 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COUNTS: fJ(c';c,,Ci1) 1 S c.ocv- (6A, p1:.,,., r cr-.) Prvv3,4-- tcy re l-,(qi • Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer ofproperty,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy ofthe system under current conditions limed on the available information. i:Ip 0 o . o 4s : _ CITY of ORONO )4,. -*,_, �;�' oPA � ti Municipal Offices ti �G Street Address: gSa-a49-460 O 1 f'r , Mailing Address: ..:143Y-4„,+"" $ 2750 Kelley Parkway P.O. Box 66 - Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: 1 62-° '`,,-:-\\kr,-, 0Y, N City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): '3 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 0"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any . reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): U Tank inspection indicates: 5 Pumpout not needed at this time. Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfreld. Ask pumper to test alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. D t I IELD CONDITION(8-10): QDrainfield is dry,no surfacing evident. • Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENT : a1�..�'�(� �� hd c ( \ a�'S' a- t• v t c- \�Cc cJ -lt \-1- )-' \ , i/ Set L S S v ,,,,,,,k/ Q>, o'S' - \•\. --.01—\ i •-i-K a, Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information.